1000W Modified Sine Wave DC-AC Power Inverter A-301/302-1K0 series Features : 12V or 24V DC input Power ON-OFF switch Input voltage range: -15% ~ +25% Output voltage regulation: 10% Protections: Bat. Low alarm/Bat. Low shutdown/Over voltage/ Over temp./Output short/Input polarity reverse/Over load. Output waveform: Modified sine wave Cooling fan ON-OFF control ON/OFF remote control(Optional) Approvals: e13/ CE 1 year warranty E S SPECIFICATION Germany ORDER NO. OUTPUT A301-1K0-B2 SAFETY MODEL NO. A-1000W AC VOLTAGE 110V RATED POWER 1000W PEAK POWER 1200W<30min. SURGE POWER 2400W WAVEFORM Modified Sine Wave FREQUENCY 60Hz 1% AC REGULATION INPUT ENVIRONMENT A302-1K0-B2 A302-1K0-F3 230V 110V 230V 50Hz 1% 60Hz 1% 50Hz 1% 10% TYPE-3* 2ea TYPE-2* 3ea Green LED for power on; Yellow LED for O.T.P.; Red LED for power failure status Germany LVD tested DC CURRENT 110A 55A NO LOAD CURRENT DRAW 0.4A 0.2A DC VOLTAGE 12V 24V VOLTAGE RANGE 10 ~ 15VDC 21 ~ 30VDC EFFICIENCY (Typ.) 85% 1000mm R type terminal FUSE 82% 1000mm R type terminal 30A*5 BAT. LOW ALARM 10 0.5V 21 0.8V BAT. LOW SHUTDOWN 9.5 0.5V 20 0.8V TYPE-3* 2ea TYPE-2* 3ea 20A*5 >1200W shut down o/p voltage, re-power to recover 29 ~ 31V 15 ~ 16V 60 5 o / 140 9 F OUTPUT SHORT Shut-off BAT. POLARITY By fuse open WORKING TEMP. 0 ~ 30 WORKING HUMIDITY 20% ~ 90% RH non-condensing @ 100% load, 40 @ 70% load EMC o STORAGE TEMP., HUMIDITY -30 ~ +70 / -22 ~ +158 F, 10 ~ 95% RH TEMP. COEFFICIENT 0.05% / (0 ~ 50 ) I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH ISOLATION RESISTANCE EMI CONDUCTION & RADIATION Compliance to EN55022 class B, 72/ 245/ CEE, 95/ 54/ CE Compliance to EN61000-4-2,3 EMS IMMUNITY Compliance to EN60950 OTHERS LVD MTBF DIMENSION PACKING COOLING APPLICATIONS >40 (NTC) fan on Home appliance, Power tools, Office and Portable equipment and Vehicle ...etc. SAFETY & E S 10% STANDARD RECEPTACLES OVER LOAD PROTECTION OVER VOLTAGE OVER TEMPERATURE tested A301-1K0-F3 LED INDICATOR DC CONNECTOR EMC 98Khrs min. MIL-HDBK-217F (25 310*210*85mm (L*W*H) 3.3kg ; 4pcs / 17.5kg / CARTON ) AC Output Receptacles (optional) TYPE-1 TYPE-2 TYPE-3 TYPE-4 TYPE-5 TYPE-6 JAPAN USA EUROPE UNIVERSAL AUSTRALIA U.K File Name: A-301/302-1K0-SPEC 2007-05-14 1000W Modified Sine Wave DC-AC Power Inverter A-301/302-1K0 series Mechanical Specification Unit:mm MADE IN TAIWAN WARNING: DO NOT REVERSE INPUT FAN 310 219 AIR FLOW DC CABLE 2 LENGTH:1000mm 14mm 210 10.6 240 AC OUTPUT ON AC OUTPUT REMOTE CONTROL NORMAL NORMAL ON OVER TEMP. OVER LOAD 85 REMOTE CONTROL OVER TEMP. OVER LOAD OFF 10 OFF USA EUROPE File Name: A-301/302-1K0-SPEC 2007-05-14