MEANWELL S-100F-12

S-100F
100W Single Output Switching Power Supply
series
Features :
AC input range selectable by switch
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 83KHz
2 years warranty
(for 24V only)
SPECIFICATION
MODEL
S-100F-5
S-100F-7.5
S-100F-12
S-100F-15
S-100F-24
DC VOLTAGE
5V
7.5V
12V
15V
24V
48V
RATED CURRENT
20A
13.5A
8.5A
6.7A
4.5A
2.2A
CURRENT RANGE
0 ~ 20A
0 ~ 13.5A
0 ~ 8.5A
0 ~ 6.7A
0 ~ 4.5A
0 ~ 2.2A
RATED POWER
100W
101W
102W
100.5W
108W
105.6W
125mVp-p
125mVp-p
125mVp-p
150mVp-p
150mVp-p
6.75 ~ 8.25V
10.8 ~ 13.2V
13.5 ~ 16.5V
21.6 ~ 26.4V
43.2 ~ 52.8V
RIPPLE & NOISE (max.) Note.2 100mVp-p
OUTPUT
INPUT
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3
2.0%
1.0%
1.0%
1.0%
1.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
SETUP, RISE TIME
1000ms, 30ms at full load
HOLD UP TIME (Typ.)
20ms at full load
VOLTAGE RANGE
88 ~ 132VAC/176 ~ 264VAC selected by jumper or switch
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
76%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
3.15A/115VAC
1.5A/230VAC
COLD START 20A/115VAC
40A/230VAC
(Note 4)
OTHERS
81%
<1mA / 240VAC
OVERLOAD
OVER VOLTAGE
5.75 ~ 6.75V
8.63 ~ 10.13V
13.8 ~ 16.2V
17.25 ~ 20.25V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
WORKING TEMP.
-10 ~ +60
83%
84%
27.6 ~ 32.4V
55.2 ~ 64.8V
(Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
TEMP. COEFFICIENT
VIBRATION
0.03%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
WITHSTAND VOLTAGE
CSA60950-1 (for 24V only), UL1012, UL60950-1, TUV EN60950-1 Approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A
MTBF
314.9K hrs min. MIL-HDBK-217F (25
199*98*38mm (L*W*H)
0.65Kg; 20pcs/14.2Kg/0.8CUFT
DIMENSION
PACKING
NOTE
80%
105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
EMC
78%
248 ~ 370VDC
LEAKAGE CURRENT
PROTECTION
SAFETY &
4.5 ~ 5.5V
S-100F-48
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:S-100F-SPEC 2007-01-23
S-100F
100W Single Output Switching Power Supply
Mechanical Specification
Case No. 902
series
Unit:mm
3.5
12
9
7
197
1
9.5
2
98
80
4
85.5
3
8.2
5
6
7
4-
3.5
M
3
57.5
4.5
120
199
190
28.5
3
38
18
3.5
3-M
3.5
18
9
9.5
6.5
157
22
Terminal Pin No. Assignment
Pin No.
1
2
3
Pin No.
4,5
6,7
Assignment
AC/L
AC/N
FG
Assignment
DC OUTPUT -V
DC OUTPUT +V
Derating Curve
Static Characteristics (24V)
OUTPUT VOLTAGE (V)
S-100F-12,24
100
80
S-100F-5,7.5
LOAD (%)
60
40
20
-10
-10
0
0
10
20
30
40
50
45
AMBIENT TEMPERATURE ( )
60
55
(VERTICAL)
(HORIZONTAL)
350
28
300
24
250
20
200
16
150
12
100
8
50
80
160
85
170
90
180
95
190
100
200
105
210
110
220
115
230
120
240
125
250
OUTPUT RIPPLE (mVp-p)
Ta=25
32
130
260
INPUT VOLTAGE (V) 60Hz
File Name:S-100F-SPEC 2007-01-23