30W Single Output Industrial DIN Rail Power Supply DR-30 series Features : Universal AC input/Full range Protections: Short circuit / Overload / Over voltage Cooling by free air convection Can be installed on DIN rail TS-35/7.5 or 15 Isolation class LED indicator for power on 100% full load burn-in test 3 years warranty SPECIFICATION MODEL DR-30-5 DR-30-12 DR-30-15 DR-30-24 DC VOLTAGE 5V 12V 15V 24V RATED CURRENT 3A 2A 2A 1.5A CURRENT RANGE 0 ~ 3A 0 ~ 2A 0 ~ 2A 0 ~ 1.5A RATED POWER 15W RIPPLE & NOISE (max.) Note.2 80mVp-p OUTPUT INPUT VOLTAGE ADJ. RANGE 21.6 ~ 26.4V 1.0% LINE REGULATION 1.0% 1.0% 1.0% 1.0% LOAD REGULATION 1.0% 1.0% 1.0% 1.0% SETUP, RISE TIME 100ms, 30ms/230VAC HOLD UP TIME (Typ.) 100ms/230VAC VOLTAGE RANGE 85 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz 100ms, 30ms/115VAC at full load 21ms/115VAC at full load 120 ~ 370VDC EFFICIENCY (Typ.) 74% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 0.88A/115VAC 0.48A/230VAC COLD START 15A/115VAC 30A/230VAC OVERLOAD 105 ~ 160% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V 81% 82% 83% Protection type : Shut down o/p voltage, re-power on to recover -20 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 UL60950-1, TUV EN60950-1 approved, Design refer to EN50178 I/P-O/P:3KVAC ISOLATION RESISTANCE I/P-O/P:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55011,EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 HARMONIC CURRENT EMS IMMUNITY Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A MTBF 441.5K hrs min. MIL-HDBK-217F (25 78*93*56mm (W*H*D) 0.27Kg; 48pcs/14Kg/1.02CUFT DIMENSION PACKING NOTE 13.5 ~ 16.5V 1.0% TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE OTHERS 10.8 ~ 13.2V 1.0% WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY (Note 4) 36W 150mVp-p 2.0% OVER VOLTAGE EMC 30W 120mVp-p VOLTAGE TOLERANCE Note.3 PROTECTION SAFETY & 4.75 ~ 5.5V 24W 120mVp-p ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. File Name:DR-30-SPEC 2008-04-07 DR-30 30W Single Output Industrial DIN Rail Power Supply Mechanical Specification series Case No. 918B Unit:mm 68 45 47 56 27.4 Terminal Pin No. Assignment Pin No. 5,6 7 8 Assignment AC/N AC/L +V Assignment -V LED +V ADJ. 3 Pin No. 1 2 3,4 46.5 46.5 93 12.2 5 5 5 8 6 5 4 3 7 37.75 78 35 2 1 5 ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15 Block Diagram RECTIFIERS & FILTER EMI FILTER I/P POWER SWITCHING RECTIFIERS & FILTER +V -V DETECTION CIRCUIT O.L.P. CONTROL O.V.P. Derating Curve Output Derating VS Input Voltage Ta=25 100 100 90 80 80 70 LOAD (%) LOAD (%) 60 40 20 -20 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 70 (VERTICAL) 60 50 40 85 95 100 115 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz File Name:DR-30-SPEC 2008-04-07