45W Single Output Industrial DIN Rail Power Supply DR-45 series Features : Universal AC input/Full range Protections: Short circuit / Overload / Over voltage / Over temperature Cooling by free air convection Can be installed on DIN rail TS-35/7.5 or 15 UL 508(industrial control equipment)approved LED indicator for power on 100% full load burn-in test Fix switching frequency at 100KHz 3 years warranty SPECIFICATION MODEL DR-4505 DR-4512 DR-4515 DR-4524 DC VOLTAGE 5V 12V 15V 24V RATED CURRENT 5A 3.5A 2.8A 2A CURRENT RANGE 0 ~ 5A 0 ~3. 5A 0 ~ 2.8A 0 ~ 2A RATED POWER 25W 42W 42W 48W 200mVp-p 240mVp-p 480mVp-p 10.8 ~ 13.2V 13.5 ~ 16.5V 21.6 ~ 26.4V RIPPLE & NOISE (max.) Note.2 100mVp-p OUTPUT INPUT VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note.3 2.0% 1.0% 1.0% 1.0% LINE REGULATION 1.0% 1.0% 1.0% 1.0% LOAD REGULATION 1.0% 1.0% 1.0% 1.0% SETUP, RISE TIME 800ms, 60ms/230VAC at full load HOLD UP TIME (Typ.) 100ms/230VAC at full load VOLTAGE RANGE 85 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz 72% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.5A/115VAC 0.75A/230VAC COLD START 28A/115VAC 56A/230VAC OVERLOAD Protection type : Shut off o/p voltage, clamping by zener diode Tj 135 typically (U1) detect on heat sink of power transistor Protection type : Shut down o/p voltage, re-power on to recover -10 ~ +50 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 UL508, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55011,EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 HARMONIC CURRENT EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, EN61000-6-2 (EN50082-2), heavy industry level, criteria A MTBF 364.6K hrs min. MIL-HDBK-217F (25 93*78*67mm (L*W*H) 0.31Kg; 48pcs/16.1Kg/1.3CUFT DIMENSION PACKING NOTE 80% <1mA / 240VAC TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE OTHERS 77% 105 ~ 150% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY (Note 4) 77% LEAKAGE CURRENT OVER TEMPERATURE EMC 120 ~ 370VDC EFFICIENCY (Typ.) PROTECTION OVER VOLTAGE SAFETY & 4.75 ~ 5.5V ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. File Name:DR-45-SPEC 2008-04-07 DR-45 45W Single Output Industrial DIN Rail Power Supply Mechanical Specification Unit:mm 29 67 Case No. 918A series 7.5 8.5 46.5 46.5 9 8 7 6 35 78 5 4 3 2 Install DIN rail TS35/7.5 or TS35/15 1 Terminal Pin No. Assignment Pin No. 1 2 3 4,5 Assignment AC/L AC/N FG DC OUTPUT -V 77 Pin No. 6,7 8 9 93 Assignment DC OUTPUT+V LED +V ADJ. Block Diagram fosc : 100KHz RECTIFIERS & FILTER EMI FILTER I/P POWER SWITCHING RECTIFIERS & FILTER PWM CONTROL DETECTION CIRCUIT FG Derating Curve +V -V Static Characteristics (24V) OUTPUT VOLTAGE (V) 100 80 LOAD (%) 60 40 20 -10 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 (VERTICAL) 350 28 300 24 250 20 200 16 150 12 100 8 50 70 80 100 120 140 160 180 200 220 240 OUTPUT RIPPLE (mVp-p) Ta=25 32 260 INPUT VOLTAGE (V) 60Hz File Name:DR-45-SPEC 2008-04-07