PB-230 230W Single Output Battery Charger series Features : 3 stage charging characteristic Universal AC input / Full range Built-in active PFC function, PF>0.95 Protection: Short circuit / Overload / Over voltage / Over temperature Built-in cooling Fan ON-OFF control Built-in remote ON-OFF control 2 color LED loading indicator Low cost, high reliability 2 years warranty ( for PB-230-xxAD1 only) ORDER NO. OUTPUT CONNECTOR SAFETY PB-230-xx (standard model) 4pin power din TUV / CE PB-230-xxAD1 (optional model) Anderson connector UL PB-230-xx xx=12,24,48 ; TUV Rheinland Product Safety geprUfre Sicherheit =Blank, AD1 SPECIFICATION MODEL OUTPUT INPUT PROTECTION PB-230-12 PB-230-24 PB-230-48 BOOST CHARGE VOLTAGE 14.4V 28.8V 57.6V FLOAT CHARGE VOLTAGE 13.6V 27.2V 54.4V 50 ~ 160Ah 24 ~ 80Ah 12 ~ 40Ah 8A 4A RECOMMENDED BATTERY CAPACITY(AMP HOURS)(Note 5) BATTERY TYPE Open & Sealed Lead Acid OUTPUT CURRENT 16A VOLTAGE RANGE 90 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz 127 ~ 370VDC POWER FACTOR (Typ.) PF>0.95/230VAC EFFICIENCY (Typ.) 81.5% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 3A/115VAC 1.5A/230VAC COLD START 50A LEAKAGE CURRENT <3.5mA / 240VAC OVERLOAD 90 ~ 110% rated output current Protection type : Constant current limiting, recovers automatically after fault condition is removed OVER VOLTAGE PF>0.98/115VAC at full load 85.5% 86% 31 ~ 35V 16 ~ 18V Protection type : Shut down o/p voltage, re-power on to recover Protection type : Automatically derate charge current until zero OVER TEMPERATURE REMOTE CONTROL (CN105) Open: Normal work FUNCTION FAN CONTROL RTH3 50 Fan ON, TEMPERATURE SENSE By NTC WORKING TEMP. -20 ~ +50 59 ~ 64V Short: Stop Charging 45 Fan OFF (Typ.) (Refer to output load derating curve) 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH TEMP. COEFFICIENT 0.03%/ (0 ~ 50 VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL1012(for PB-230-xxAD1 only), TUV EN60950-1 approved SAFETY STANDARDS SAFETY & EMC (Note 4) OTHERS CONNECTOR NOTE WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B / 70% RH HARMONIC CURRENT EMS IMMUNITY Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A MTBF DIMENSION 244.5Khrs min. MIL-HDBK-217F (25 ) PACKING PLUG 190*96*49mm(L*W*H) 1.21Kg; 12pcs/15.5Kg/1.29CUFT See page 2 ; Other type available by customer requested CABLE See page 2 ; Other type available by customer requested 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. This is Mean Well's suggested range. Please consult your battery manufacturer for their suggestions about maximum charging current limitation. File Name:PB-230-SPEC 2010-09-01 PB-230 230W Single Output Battery Charger Mechanical Specification Case No.PB-230A series Unit:mm 115cm 5cm 3 2 4 AD1 (optional) 1 CN105 12 96 FUSE 35 2mm Air flow direction Remote Control (CN105) : JST B2B-XH or equivalent 49 Pin No. 1 2 Assignment RCRC+ Mating Housing Terminal JST XHP or equivalent JST SXH-001T-P0.6 or equivalent 190 Plug Assignment DC output connector (standard) DC output connector (optional) AD1 [ housing: Anderson 1327FP(red), 1327G6FP(black) contacts: Anderson 261G2 (45A) or equivalent ] UNICABLE 89M103-4P or equivalent 3 2 4 1 PIN NO. OUTPUT 1,2 +V 3,4 -V Red(+V) Black(-V) Block Diagram FAN ON/OFF CONTROL EMI FILTER & RECTIFIERS I/P RECTIFIERS & FILTER POWER SWITCHING PFC CIRCUIT FG +V -V DETECTION CIRCUIT PWM & PFC CONTROL O.L.P. fosc : 90KHz FAN O.T.P. O.V.P. REMOTE CONTROL Derating Curve Charging Curve Start 100 V boost 90 V FLT Charge Voltage 80 100% Charge Current 10% Constant Current Constant Voltage stage 1 stage 2 Red Color of LED stage 3 Green LOAD (%) 70 60 40 30 -20 10 20 30 40 45 50 60 70 (HORIZONTAL) AMBIENT TEMPERATURE ( ) State V boost V FLT PB-230-12 14.4V 13.6V PB-230-24 28.8V 27.2V PB-230-48 57.6V 54.4V File Name:PB-230-SPEC 2010-09-01