SP-100 100W Single Output with PFC Function series Features : Universal AC input / full range Built-in active PFC function, PF>0.93 Protections: Short circuit / Overload / Over voltage Built-in constant current limiting circuit Remote ON-OFF control(Optional) LED indicator for power on 100% full load burn-in test Fixed switching frequency at PFC:67KHz PWM:134KHz 3 years warranty SPECIFICATION MODEL SP-100-3.3 SP-100-5 SP-100-7.5 SP-100-12 SP-100-13.5 SP-100-15 SP-100-24 SP-100-27 SP-100-48 DC VOLTAGE 3.3V 5V 7.5V 12V 13.5V 15V 24V 27V 48V RATED CURRENT 20A 20A 13.5A 8.5A 7.5A 6.7A 4.2A 3.8A 2.1A CURRENT RANGE 0 ~ 20A 0 ~ 20A 0 ~ 13.5A 0 ~ 8.5A 0 ~ 7.5A 0 ~ 6.7A 0 ~ 4.2A 0 ~ 3.8A 0 ~ 2.1A RATED POWER 66W 100W 101.25W 102W 101.25W 100.5W 100.8W 102.6W 100.8W 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 250mVp-p RIPPLE & NOISE (max.) Note.2 100mVp-p OUTPUT INPUT VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note.3 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 1.0% 1.0% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% LOAD REGULATION 1.0% 1.0% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% SETUP, RISE TIME 600ms, 30ms at full load HOLD UP TIME (Typ.) 20ms at full load VOLTAGE RANGE 85 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.93/230VAC EFFICIENCY (Typ.) 70% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.7A/115VAC 0.8A/230VAC COLD START 30A/230VAC LEAKAGE CURRENT <2mA / 240VAC PROTECTION OVER VOLTAGE VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE EMC (Note 4) OTHERS PF>0.98/115VAC at full load 76% 78% 80% 80% 82% 84% 83% 82% 105 ~ 150% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed 3.63 ~ 4.46V 5.5 ~ 6.75V 8.25 ~ 10.13V 13.2 ~ 16.2V 14.85 ~ 18.23V 16.5 ~ 20.25V 26.4 ~ 32.4V 29.7 ~ 36.45V 52.8 ~ 64.8V Protection type : Shut down o/p voltage, re-power on to recover 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.05%/ (0 ~ 50 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B / 70% RH HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY MTBF Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A DIMENSION PACKING NOTE 120 ~ 370VDC REMOTE CONTROL(OPTION) CN1:4 ~ 10VDC POWER ON, <0 ~ 0.8VDC POWER OFF -10 ~ +60 (Refer to output load derating curve) WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT SAFETY & 7.13 ~ 8.25V 11.4 ~ 13.2V 12.8 ~ 14.9V 14.3 ~ 16.5V 22.8 ~ 26.4V 25.7 ~ 29.7V 45.6 ~ 52.8V LINE REGULATION OVERLOAD FUNCTION 3.14 ~ 3.63V 4.75 ~ 5.5V 211.3K hrs min. MIL-HDBK-217F (25 179*99*45mm (L*W*H) 0.66Kg; 20pcs/14.3Kg/1.17CUFT ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) File Name:SP-100-SPEC 2010-10-18 SP-100 100W Single Output with PFC Function Mechanical Specification Case No. 915A series Unit:mm 179 20 25 123 25 117 60 65 CN1 1 2 R.C. +V ADJ. LED 2-M4 L=5mm 5-M3 L=3mm 49.5 3 2 8 99 79 5 4 38 9.5 6 119 51 7 16 10 1 Terminal Pin No. Assignment 15 Assignment AC/L AC/N FG Pin No. 1 2 3 142 25 12 max. Assignment DC OUTPUT -V DC OUTPUT +V Pin No. 4,5 6,7 45 Pin No. 1 2 12.5 25 25 Remote ON/OFF(CN1): JST S2B-XH or equivalent(optional) Assignment RC+ RC- Mating Housing Terminal JST XHP or equivalent JST SXH-001T-P0.6 or equivalent 6-M4 L=6mm PFC fosc : 67KHz PWM fosc : 134KHz Block Diagram EMI FILTER & RECTIFIERS I/P RECTIFIERS & FILTER POWER SWITCHING PFC CIRCUIT FG +V -V CONSTANT CURRENT & DETECTION CIRCUIT PWM & PFC CONTROL ACTIVE START CIRCUIT O.V.P. REMOTE CONTROL Derating Curve CN1 Output Derating VS Input Voltage Ta=25 SP-100-12~48 SP-100-3.3~7.5 (With 18CFM FAN) 100 100 90 80 80 SP-100-3.3 SP-100-5 SP-100-7.5 70 LOAD (%) LOAD (%) 60 40 20 -10 -10 0 0 10 10 20 20 40 45 50 55 55 60 AMBIENT TEMPERATURE ( ) 60 (HORIZONTAL) 70 (VERTICAL) 60 50 40 85 100 115 135 155 230 264 INPUT VOLTAGE (VAC) 60Hz File Name:SP-100-SPEC 2010-10-18