PB-360 360W Single Output Battery Charger series Features : 3 stage charging AC 115/230VAC selected by switch Built-in passive PFC function compliance to EN61000-3-2 Class A (option) Protection: Overload / Short circuit / Reverse polarity / Over voltage / Over temperature Charger for lead-acid batteries 2 color LED loading indicator Low cost, High reliability FAN on/off control(Depends on charging current) 2 years warranty (except for 48V) PB 300/360 P (P type only) 12 1.300W without FAN 2.360W with FAN 12:14.4V 24:28.8V 48:57.6V P:With Passive PFC N:Without Passive PFC SPECIFICATION MODEL PB-360 -12 PB-360 -48 28.8V FLOAT CHARGE VOLTAGE 13.6V 27.2V 54.4V 26 ~ 28.8V 52 ~ 58.6V 40 ~ 125Ah 20 ~ 65Ah RECOMMENDED BATTERY CAPACITY(AMP HOURS)(Note 5) INPUT PB-360 14.4V VOLTAGE ADJUSTABLE RANGE 13 ~ 14.7V OUTPUT -24 BOOST CHARGE VOLTAGE 80 ~ 200Ah 57.6V BATTERY TYPE Open & Sealed Lead Acid OUTPUT CURRENT 24.3A VOLTAGE RANGE 90 ~ 132VAC / 180 ~ 264VAC selected by switch FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 85% POWER FACTOR (Typ.) >0.65 (with P type) at 230VAC AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 7A/115VAC 3.5A/230VAC COLD START 60A LEAKAGE CURRENT <3.5mA / 240VAC OVERLOAD 90 ~ 110% rated output current Protection type : Constant current limiting, recovers automatically after fault condition is removed SHORT CIRCUIT PROTECTION REVERSE POLARITY OVER VOLTAGE OVER TEMPERATURE FUNCTION REMOTE CONTROL (CN5) WORKING TEMP. 12.5A 6.25A 248 ~ 370VDC 86% 87% O/P Built in fuse (FS100) to protect short circuit condition, shut down o/p voltage and can not re-power on By internal fuse 16 ~ 18V 31 ~ 35V Protection type : Shut down o/p voltage, re-power on to recover Protection type : Automatically derate charge current until zero Open: Normal work 59 ~ 64V Short: Stop Charging -20 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH TEMP. COEFFICIENT 0.05%/ (0 ~ 45 VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes IEC60335-2-29 CB approved by TUV(except for 48V), UL60950-1 approved SAFETY STANDARDS SAFETY & EMC (Note 4) WITHSTAND VOLTAGE MTBF DIMENSION PACKING NOTE I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B HARMONIC CURRENT EMS IMMUNITY OTHERS I/P-O/P:3KVAC ISOLATION RESISTANCE / 70% RH Compliance to EN61000-3-2,-3 (only P type) Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A 115.8Khrs min. MIL-HDBK-217F (25 ) 253*135*48.5mm(L*W*H) 1.5Kg; 6pcs/10Kg/0.95CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. This is Mean Well's suggested range. Please consult your battery manufacturer for their suggestions about maximum charging current limitation. File Name:PB-360-SPEC 2008-11-11 PB-360 360W Single Output Battery Charger Mechanical Specification Case No.801A series Unit:mm 253 235 12 54 127 48.5 11 12 135 230 LED +V SVR1 CN5 -V ON/OFF SWITCH INLET 9.25 9 .75 5.5 Air flow direction Remote Control(CN5) : JST B2B-XH or equivalent Assignment PIN1,2 Open: Normal work PIN1,2 Short: Stop Charging Mating Housing Terminal JST XHP or equivalent JST SXH-001T-P0.6 or equivalent Block Diagram fosc : 70KHz FAN ON/OFF CONTROL RECTIFIERS & PASSIVE P.F.C. EMI FILTER I/P POWER SWITCHING POLARITY REVERSE PROTECTION RECTIFIERS & FILTER +V -V O.C.P. FG O.L.P. DETECTION CIRCUIT PWM CONTROL O.V.P. Output Load VS Temperature Charging Curve Start 100 V boost 90 V FLT Charge Voltage 80 100% Charge Current Constant Current Constant Voltage stage 1 LED COLOR stage 2 Red stage 3 Green LOAD (%) 70 60 40 30 -20 10 20 30 40 50 60 70 AMBIENT TEMPERATURE ( ) State V boost V FLT PB-360-12 14.4V 13.6V PB-360-24 28.8V 27.2V PB-360-48 57.6V 54.4V File Name:PB-360-SPEC 2008-11-11