MEANWELL PSD-05-12

P S D - 0 5 series
5W Single Output DC-DC Converter
Features :
2:1 wide input range
Protections:Short circuit/Over load /Over voltage/Over
temperature
Built-in EMI filter,low ripple noise
3
100% full load burn-in test
Fix switching frequency at 67KHz
Low cost
High reliability
1 year warranty
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
OUTPUT
PSD-05-05
PSD-05-12
PSD-05-24
5V
1A
0 ~ 1A
12V
0.45A
0 ~ 0.5A
5.4W
24V
0.22A
0 ~ 0.25A
5.28W
100mVp-p
2.0%
150mVp-p
2.0%
CURRENT RANGE
5W
RATED POWER
RIPPLE & NOISE (max.) Note.2 50mVp-p
VOLTAGE TOLERANCE Note.3
2.0%
LINE REGULATION
1.0%
LOAD REGULATION
INPUT
1.0%
SETUP, RISE, HOLD UP TIME 1.2s, 20ms,--- at full load
36 ~ 72VDC
VOLTAGE RANGE
EFFICIENCY(Typ.)
75%
0.15A/48V
DC CURRENT(Typ.)
1.0%
0.5%
1.0%
0.5%
78%
78%
Above 105% rated output power
OVER LOAD
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
Protection type : Fold back current limiting, recovery automatically after fault condition is removed
13.8~16.2V
5.75~ 6.75V
Protection type : Hiccup mode, recovery automatically after fault condition is removed
U1 Tj140 æ
27.6~ 32.4V
typically(U1)Detect on main control IC
¡
WORKING TEMP.
Protection type : Hiccup mode, recovery automatically after temperature goes down
-10 ~ +60 æ (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
0.05%/ (0 ~ 50 )
TEMP. COEFFICIENT
SAFETY &
EMC
OTHERS
NOTE
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, Period for 60min.each along X, Y, Z axes
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:2KVAC
EMS IMMUNITY
Compliance to EN61000-4-2, 3, 4, 6, 8 ENV50204, EN55024, EN61000-6-1 Light industry level, criteria A
DIMENSION
PACKING
75*40*20mm (L*W*H)
50mg;120pcs/6.25Kg/1CUFT
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
1. All parameters NOT specially mentioned are measured at 48VDC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4.The power supply is considered a component which will be installed into a final equipment.The final equipment must be re-confirmed that it
still meets EMC directives.
File Name:PSD-05-SPEC 2006-08-22
P S D - 0 5 series
5W Single Output DC-DC Converter
Mechanical Specification
Unit:mm
75
4
67
CN2
3.96
5
32
1
2
3
11.5
40
5
16.5
4
To chassis Grounding
1
2
CN1
20
4-3.5 Dia
Mounting Holes
DC Input Connector (CN2) : MOLEX5285-03 or equivalent
Assignment
FG
(-V)
(+V)
Pin No.
1
2
3
Mating Housing
Terminal
MOLEX 5058
or equivalent
MOLEX 2478
or equivalent
DC Output Connector (CN1) : MOLEX5273-02 or equivalent
Pin No.
1
2
Assignment
+V
-V
Mating Housing
Terminal
MOLEX 5195
or equivalent
MOLEX 5194
or equivalent
Block Diagram
fosc : 67KHz
RECTIFIERS
&
FILTER
EMI
FILTER
I/P
RECTIFIERS
&
FILTER
POWER
SWITCHING
PWM
CONTROL
+V
-V
DETECTION
CIRCUIT
FG
Derating Curve
Static Characteristics
100
100
80
90
80
70
40
LOAD(%)
LOAD (%)
60
20
-10
-10
0
10
20
30
40
AMBIENT TEMPERATURE (
50
45
)
60
55
60
50
40
(HORIZONTAL)
(VERTICAL)
36
48
72
INPUT VOLTAGE
File Name:PSD-05-SPEC 2006-08-22