1200W Single Output With Parallel Function SCN-1K2 series Features : AC input 200~260V only Protections: Short circuit / Overload / Over voltage / Over temp. High reliability/ Low ripple noise Built-in remote sense function Built-in remote ON-OFF control Built-in parallel operation function Can adjust from 20~100% output voltage by external control 1-5V Forced air cooling by built-in DC fan Case coating with paint 2 years warranty SPECIFICATION ORDER NO. SCN-1K2-05 SCN-1K2-12 SCN-1K2-15 SCN-1K2-24 SCN-1K2-48 1K2S-N012 1K2S-N015 1K2S-N024 1K2S-N048 DC VOLTAGE 1K2S-N005 5V 12V 15V 24V 48V RATED CURRENT 180A 100A 80A 50A 24A CURRENT RANGE 0 ~ 180A 0 ~ 100A 0 ~ 80A 0 ~ 50A 0 ~ 24A RATED POWER 900W 1200W 1200W 1200W 1152W 120mVp-p 150mVp-p 240mVp-p 480mVp-p SAFETY MODEL NO. OUTPUT RIPPLE & NOISE (max.) Note.2 100mVp-p VOLTAGE ADJ. RANGE 5.0% typical adjustment by potentiometer 1.0% VOLTAGE TOLERANCE Note.3 2.5% 20 ~ 100% adjustment by 1 ~ 5VDC external control 1.0% 1.0% 1.0% LINE REGULATION 0.5% 0.5% 0.5% 0.5% 0.5% LOAD REGULATION 2.0% 0.5% 0.5% 0.5% 0.5% SETUP, RISE, HOLD UP TIME 800ms, 50ms, 16ms at full load INPUT VOLTAGE RANGE 200 ~ 260VAC 290 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 77% 11A / 230VAC AC CURRENT INRUSH CURRENT (max.) OVERLOAD ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE (Note. 4) OTHERS NOTE 120A / 230VAC 3.5mA / 240VAC WORKING TEMP. WORKING HUMIDITY ISOLATION RESISTANCE 87% 85% 101 ~ 115% 110 ~ 135% rated output power Protection type : Current limiting, delay shut down o/p voltage, re-power on to recover OVER TEMPERATURE EMC 85% LEAKAGE CURRENT (max.) PROTECTION OVER VOLTAGE SAFETY & 83% 110 ~ 135% follow to output set up point Protection type : Shut down o/p voltage, re-power on to recover >100 / measure by heat sink, near transformer Protection type : Shut down o/p voltage, re-power on to recover -10 ~ +65 (Refer to output load derating curve) 20% ~ 90% RH non-condensing -20 ~ +85 0.04% / , 10 ~ 95% RH (0 ~ 50 ) 10 ~ 200Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, CSA22.2, IEC60950 approved I/P-O/P, I/P-FG :1500VAC I/P-O/P, I/P-FG, >100M Ohms / 500VDC / 25 / 70% RH EMI CONDUCTION & RADIATION Compliance to FCC part 15 class A ---HARMONIC CURRENT EMS IMMUNITY MTBF ---60Khrs min. MIL-HDBK-217F (25 DIMENSION PACKING SPECIAL FUNCTION 291*132*132mm (L*W*H) 4.75kg ; 4pcs/20kg/CARTON DC voltage adj., Remote sensing, remote control, parallel operation (refer to terminal instruction manual) ) 1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. 2.Tolerence: includes set up tolerance, line regulation, load regulation. 3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. File Name:SCN-1K2-SPEC 2008-05-06 SCN-1K2 1200W Single Output With Parallel Function Mechanical Specification series Unit:mm 291 200 199.5 L N FG #6-32-4 M3(NUT).x3H-4 30 132 AC INPUT VS+ VSVCI VCD GND PAR GND INH 14.5 50.5 41 V ADJ LED 15 POS+ 291 250 32 POS M6 7.5 AC INPUT BUTTON SIDE NEG DC OUTPUT Air flow direction 132 9.5 M3(NUT)x3H-4 115 9 NEG- Terminal Pin No. Assignment Pin No. 1 2 3 Control terminal Pin No. Assignment (CN1) : Dinkle 51HDBC-O8P or equivalent Assignment AC/L AC/N FG Pin No. 1 2 3 4 Assignment VS+ VSVCI VCO Assignment Mating With GND PAR Dinkle 51SDB-O8P or equivalent GND INH Pin No. 5 6 7 8 External DC Control VS Output Voltage Derating Curve O.V.P. Vout 100 OUTPUT VOLTAGE (%) LOAD (%) 100 50 -10 0 10 20 30 Ta ( 40 ) 50 60 80 non-linear 60 40 20 V 1 2 3 4 5 EXTERNAL VOLTAGE(Typical) File Name:SCN-1K2-SPEC 2008-05-06 SCN-1K2 1200W Single Output With Parallel Function series Control terminal instruction manual LOAD LOAD VS+ VSVCI VCO GND PAR GND INH VS+ VSVCI VCO GND PAR GND INH USING INTERNAL VOLTAGE CONTROL LOAD VS+ VSVCI VCO GND PAR GND INH ON/OFF SWITCH ON/OFF CONTROL BY SWITCH REMOTE SENSING LOAD LOAD VS+ VSVCI VCO GND PAR GND INH VS+ VSVCI VCO GND PAR GND INH H:ON L:OFF DC 1-5V OUTPUT VOLTAGE ADJUST WITH DC 1-5V ON/OFF CONTROL BY TRANSISTOR LOAD VS+ VSVCI VCO GND PAR GND INH VS+ VSVCI VCO GND PAR GND INH VS+ VSVCI VCO GND PAR GND INH PARALLEL OPERATION WITH REMOTE SENSING LOAD VS+ VSVCI VCO GND PAR GND INH VS+ VSVCI VCO GND PAR GND INH VS+ VSVCI VCO GND PAR GND INH PARALLEL OPERATION File Name:SCN-1K2-SPEC 2008-05-06