MEANWELL SCN-600-15

SCN-600
600W Single Output With Parallel Function
series
Features :
AC input range selected by switch
Protections: Short circuit / Overload / Over voltage / Over temp.
High reliability/ Low ripple noise
Built-in remote sense function
Built-in remote ON-OFF control
Built-in parallel operation function
Can adjust from 20~100% output voltage by external control 1-5V
Forced air cooling by built-in DC fan
Case coating with paint
2 years warranty
SPECIFICATION
ORDER NO.
OUTPUT
SCN-600-05
SCN-600-12
SCN-600-15
SCN-600-18
SCN-600-24
SCN-600-48
SAFETY MODEL NO.
600S-N005
600S-N012
600S-N015
600S-N018
600S-N024
600S-N048
DC VOLTAGE
5V
12V
15V
18V
24V
48V
RATED CURRENT
100A
50A
40A
33A
25A
12A
CURRENT RANGE
0 ~ 100A
0 ~ 50A
0 ~ 40A
0 ~ 33A
0 ~ 25A
0 ~ 12A
RATED POWER
500W
600W
600W
594W
600W
576W
120mVp-p
150mVp-p
180mVp-p
240mVp-p
480mVp-p
RIPPLE & NOISE (max.) Note.2 100mVp-p
VOLTAGE ADJ. RANGE
5.0% typical adjustment by potentiometer
1.0%
VOLTAGE TOLERANCE Note.3 1.5%
20~100% adjustment by 1~5VDC external control
1.0%
1.0%
1.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
SETUP, RISE, HOLD UP TIME 800ms, 50ms, 16ms at full load
INPUT
VOLTAGE RANGE
90 ~ 130VAC / 180 ~ 260VAC selected by switch, 260 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
77%
11A / 115VAC
AC CURRENT
INRUSH CURRENT (max.)
82%
85%
3.5mA / 240VAC
OVERLOAD
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
110 ~ 135% follow to output set up point
Protection type : Shut down o/p voltage, re-power on to recover
>100 / measure by heat sink, near transformer
Protection type : Shut down o/p voltage, re-power on to recover
-10 ~ +65 (Refer to output load derating curve)
20% ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
VIBRATION
0.04% / (0 ~ 50 )
10 ~ 200Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, CSA22.2, IEC60950 approved
WITHSTAND VOLTAGE
I/P-O/P, I/P-FG:1500VAC
I/P-O/P, I/P-FG, 100M Ohms / 500VDC / 25
ISOLATION RESISTANCE
87%
60A / 230VAC
101 ~ 115%
110 ~ 135% rated output power
Protection type : Current limiting, delay shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
EMC
81%
LEAKAGE CURRENT
PROTECTION OVER VOLTAGE
SAFETY &
80%
7.0A / 230VAC
/ 70% RH
(Note. 4)
EMI CONDUCTION & RADIATION Compliance to FCC part 15 class A
---HARMONIC CURRENT
EMS IMMUNITY
----
OTHERS
MTBF
DIMENSION
PACKING
SPECIAL FUNCTION
120Khrs min. MIL-HDBK-217F (25 )
291*132*68mm (L*W*H)
2.6kg; 8pcs/ 24kg/ CARTON
DC voltage adj., Remote sensing, remote control, parallel operation (refer to terminal instruction manual)
NOTE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.Tolerence: includes set up tolerance, line regulation, load regulation.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:SCN-600-SPEC 2008-05-06
SCN-600
600W Single Output With Parallel Function
Mechanical Specification
series
Unit:mm
291
200
50.5
#6-32-4
M3(NUT)x3H-4
AC INPUT
30
VS+
VSVCI
VCO
GND
PAR
GND
INH
N FG
68
L
41
15.5
199.5
V ADJ
15
LED
POS+
NEG-
291
32
9.5
M3(NUT)x3H-4
M6.0
7.5
NEG
AC INPUT
BOTTOM SIDE
POS
DC OUTPUT
Air flow
direction
115
9
132
250
Derating Curve
External DC Control VS Output Voltage
Vout
100
OUTPUT VOLTAGE (%)
LOAD (%)
100
50
-10
O.V.P.
0
10
20
30
Ta (
40
)
50
60
80
non-linear
60
40
20
V
1
2
3
4
5
EXTERNAL VOLTAGE(Typical)
File Name:SCN-600-SPEC 2008-05-06
SCP-600
500~600W Parallel (N+1) With PFC Function
series
Control terminal instruction manual
LOAD
VS+
VSVCI
VCO
PG
PAR
GND
INH
VS+
VSVCI
VCO
PG
PAR
GND
INH
USING INTERNAL VOLTAGE CONTROL
LOAD
LOAD
LOAD
VS+
VSVCI
VCO
PG
PAR
GND
INH
VS+
VSVCI
VCO
PG
PAR
GND
INH
ON/OFF SWITCH
ON/OFF CONTROL BY TRANSISTOR
ON/OFF CONTROL BY SWITCH
REMOTE SENSING
H:ON
L:OFF
Vout
GOOD
FAIL
: LED OFF
: LED ON
O.V.P. 120% (Typ.)
120
100
VS+
VSVCI
VCO
PG
PAR
GND
INH
40V / 0.5A MAX.
POWER GOOD SIGNAL
VS+
VSVCI
VCO
PG
PAR
GND
INH
OUTPUT VOLTAGE (%)
LOAD
LOAD
DC 1-5V
80
Non-Linear
60
40
20
1
OUTPUT VOLTAGE ADJUST WITH DC 1-5V
2
3
4
5
6
EXTERNAL VOLTAGE (DC)
LOAD
VS+
VSVCI
VCO
PG
PAR
GND
INH
VS+
VSVCI
VCO
PG
PAR
GND
INH
VS+
VSVCI
VCO
PG
PAR
GND
INH
PARALLEL OPERATION WITH REMOTE SENSING
V
LOAD
VS+
VSVCI
VCO
PG
PAR
GND
INH
VS+
VSVCI
VCO
PG
PAR
GND
INH
VS+
VSVCI
VCO
PG
PAR
GND
INH
PARALLEL OPERATION WITHOUT REMOTE SENSING
File Name: SCP-600-SPEC 2008-05-06