SCN1K2 series

SCN1K2
1200W Switching Power Supply N
1 2 0 0 W W i t h P a r allel Function
series
FEATURES
High reliability and low ripple noise
Built-in remote sense function
Built-in remote ON/OFF control
Programmable output voltage
Forced current sharing at parallel operation
Output short circuit / over voltage / overload / over temperature protections
UL1950, CSA22.2 approved
MODEL No .
DC VOLTAGE
SCN1K2-05
SCN1K2-12
SCN1K2-15
5V
12V
15V
24V
48V
100A
80A
50A
25A
1200W
1200W
1200W
1200W
150mVp-p
150mVp-p
240mVp-p
480mVp-p
RATED CURRENT 180A
RATED POWER
OUTPUT
900W
RIPPLE & NOISE (max.) 150mVp-p
VOLTAGE ADJ. RANGE
SCN1K2-24
SCN1K2-48
5.0% typical adjustment by potentiometer; 20% ~ 100% adjustment by 1 ~ 5VDC external control
LINE & LOAD REGULATION Less than 1%
SETUP, RISE, HOLD TIME
VOLTAGE RANGE
FREQUENCY RANGE
INPUT
800ms, 50ms, 16ms at full load
90 ~ 130VAC / 180 ~ 260VAC
47 ~ 63Hz
EFFICIENCY (Typ.) 77%
INRUSH CURRENT (Typ.)
83%
85%
85%
87%
120A / 230VAC
LEAKAGE CURRENT (max.) < 7.0mA / 240VAC
OVER LOAD 105 ~ 115% rated output power (Current limiting, delay shut down output voltage, re-power on to recover)
PROTECTION
OVER VOLTAGE 110 ~ 135% follow to output set up point (Shut down output voltage, re-power on to recover)
OVER TEMPERATURE
> 100 C / measure by heat sink, near transformer (Shut down output voltage, re-power on to recover)
WORKING TEMP. & HUMIDITY -10 ~ +50 C ; 20% ~ 90% RH non-condensing
ENVIRONMENT
STORAGE TEMP. & HUMIDITY
TEMP. COEFFICIENT
-20 ~ +85 C , 10 ~ 95% RH
0.04% / C (0 ~ 50 C )
SAFETY STANDARDS UL1950, IEC60950 Approved
WITHSTAND VOLTAGE I/P ~ O/P, I/P ~ FG:1.5KVAC
SAFETY & EMC
ISOLATION RESISTANCE I/P~O/P, I/P~FG, O/P~FG:100M Ohms / 500VDC
EMI CONDUCTION & RADIATION Compliance to FCC part 15 class A
HARMONIC CURRENT
-----
EMS IMMUNITY ----SPECIAL FUNCTION
OTHERS
DC voltage Adj., Remote sensing, Remote control, Parallel operation
MTBF 60K hrs min. MIL-HDBK-217F(25 C)
DIMENSION
295 x 130 x 130mm (L x W x H )
PACKING 4.5kgs; 4sets / 20kgs / CARTON
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
WWW.ASTRODYNE.COM
21
*Note:The specifications are subject to change without notice.
S -C1N
SCN
K 12 Ks e2r i e ss e r i e s
1 2 0 0 W W i t h P a r allel
Function
1200W
With Parallel Function
Mechanical Specification
Unit:mm
291.0
200.0
199.5
L N FG
#6-32-4
M3(NUT).x3H-4
30.0
132.0
AC INPUT
VS+
VSVCI
VCD
GND
PAR
GND
INH
14.5
50.5
41.0
V ADJ
LED
15.0
POS+
291.0
250.0
32.0
POS
M6.0
7.5
AC INPUT
BUTTON SIDE
NEG
DC OUTPUT
Air flow
direction
132.0
9.5
M3(NUT)x3H-4
115.0
9.0
NEG-
Terminal Pin. No. Assignment
Pin No.
1
2
3
Control terminal Pin. No. Assignment (CN1) : Dinkle 51HDBC-O8P or equivalent
Assignment
AC/L
AC/N
FG
Pin No.
1
2
3
4
Assignment
VS+
VSVCI
VCO
Mating With
Assignment
GND
PAR
Dinkle 51SDB-O8P
or equivalent
GND
INH
Pin No.
5
6
7
8
External DC Control VS Output Voltage
Derating Curve
O.V.P.
Vout
100
OUTPUT VOLTAGE (%)
LOAD (%)
100
50
-10
0
10
20
30
Ta (
WWW.ASTRODYNE.COM
40
)
50
60
80
60
40
20
V
1
2
3
4
5
EXTERNAL VOLTAGE(Typical)
File Name:SCN-1K2-SPEC 2004-01-07
ASTRODYNE
USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
S -C1N
SCN
K 12 Ks e2r i e ss e r i e s
1200W
With Parallel Function
1 2 0 0 W W i t h P a r allel
Function
Control terminal instruction manual
LOAD
LOAD
LOAD
VS+
VSVCI
VCO
GND
PAR
GND
INH
VS+
VSVCI
VCO
GND
PAR
GND
INH
VS+
VSVCI
VCO
GND
PAR
GND
INH
USING INTERNAL VOLTAGE CONTROL
ON/OFF SWITCH
ON/OFF CONTROL BY SWITCH
REMOTE SENSING
LOAD
LOAD
VS+
VSVCI
VCO
GND
PAR
GND
INH
VS+
VSVCI
VCO
GND
PAR
GND
INH
H:ON
L:OFF
DC 1-5V
OUTPUT VOLTAGE ADJUST WITH DC 1-5V
ON/OFF CONTROL BY TRANSISTOR
LOAD
VS+
VSVCI
VCO
GND
PAR
GND
INH
VS+
VSVCI
VCO
GND
PAR
GND
INH
VS+
VSVCI
VCO
GND
PAR
GND
INH
PARALLEL OPERATION WITH REMOTE SENSING
LOAD
VS+
VSVCI
VCO
GND
PAR
GND
INH
VS+
VSVCI
VCO
GND
PAR
GND
INH
VS+
VSVCI
VCO
GND
PAR
GND
INH
PARALLEL OPERATION
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
File Name:SCN-1K2-SPEC 2004-01-07
WWW.ASTRODYNE.COM