MEANWELL SCW12B-05

SCW12
12W DC-DC Regulated Single Output Converter
series
Features :
2:1 wide input range
1500VDC I/O isolation
Built-in remote ON/OFF control
Built-in EMI filter
Protections: Short circuit / Overload
Cooling by free air convection
Five-sided shield metal case
100% full load burn-in test
Low cost / High reliability
Modified models available: output 2.5V/3.3V
2 years warranty
SPECIFICATION
ORDER NO.
OUTPUT
SCW12A-05
SCW12A-12
SCW12B-12
SCW12C-12
SCW12A-15
12V
15V
CURRENT RANGE
480 ~ 2400mA
200 ~ 1000mA
160 ~ 800mA
RATED POWER
12W
60mVp-p
60mVp-p
RIPPLE & NOISE (max.) Note.2 50mVp-p
LINE REGULATION
Note.3 0.5%
LOAD REGULATION
Note.4
SCW12B-15
SCW12C-15
85%
83%
0.5%
2.0%
SWITCHING FREQUENCY
VOLTAGE RANGE
400KHz min.
A: 9 ~ 18VDC
EFFICIENCY (Typ.)
82%
83%
Full load
A: 1245mA B: 625mA
C: 320mA
No load
A: 70mA
C: 25mA
DC CURRENT
B: 18 ~ 36VDC
C: 36 ~ 72VDC
84%
B: 35mA
82%
83%
83%
82%
Pi network
FILTER
Fuse recommended
PROTECTION
110 ~ 180% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
All output equipped with short circuit
OVERLOAD
PROTECTION
(Note. 5)
SCW12C-05
5V
VOLTAGE ACCURACY
INPUT
SCW12B-05
DC VOLTAGE
SHORT CIRCUIT
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-25 ~ +71
WORKING TEMP.
(Refer to output load derating curve)
20% ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -25 ~ +105 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.05% / (0 ~ 50 )
WORKING HUMIDITY
ENVIRONMENT
SAFETY
VIBRATION
WITHSTAND VOLTAGE
10 ~ 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes
ISOLATION RESISTANCE
ISOLATION CAPACITANCE
I/P-O/P: 100M Ohms / 500VDC / 25
2200pF max.
I/P-O/P:1.5KVDC
/ 70% RH
EMI CONDUCTION & RADIATION Compliance to EN55022 Class A, FCC part 15 Class A
Compliance to EN61000-4-2,3,4,5,6,8 light industry level, criteria A
EMS IMMUNITY
Power ON: R.C. ~ -Vin > 4VDC or open ; Power OFF: R.C. ~ -Vin < 1VDC or short
REMOTE CONTROL
OTHERS
MTBF
DIMENSION
600Khrs min. MIL-HDBK-217F(25 )
31.8*20.3*12.2mm or 1.25"*0.80"*0.48" inch (L*W*H)
WEIGHT
18.5g
Derating Curve
Pin Configuration
Mechanical Specification
Unit:mm(inch)
23
1
2
22
3
BOTTOM VIEW
16
17.8(0.70)
2.54( 0.10 )
2.54( 0.10 )
3.81(0.15)
SIDE
VIEW
9
5.08( 0.20 )
14
11
15.24(0.60)
12.2(0.48)
Pin No.
Output
1
2&3
9
11
14
16
22 & 23
R.C.
- Vi n
N.C.
N.C.
+ Vo u t
- Vo u t
+ Vi n
100
LOAD (%)
+ 0.2/-0
31.8(1.25)
0.6
20.3(0.80)
60
-25
0
25
50 60 71
Ta (
NOTE
100
)
1.All parameters are specified at normal input, rated load, 25 70% RH ambient.
2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
3.Line regulation is measured from low line to high line at rated load.
4.Load regulation is measured from 20% to 100% rated load.
5.Please prevent the converter from operating in overload or short circuit condition for more than 30 seconds.
File Name:SCW12-SPEC 2008-10-22