MEANWELL SUS01L-05

SUS01
1W DC-DC Unregulated Single Output Converter
series
Features :
1000VDC I/O isolation
Internal SMD technology
Built-in EMI filter
Cooling by free air convection
Non-conductive plastic case
Dual in line package
SIP packge is available
100% burn-in test
Low cost / High reliability
2 years warranty
SELECTION GUIDE
ORDER NO.
SUS01L-05
SUS01M-05
SUS01N-05
SUS01O-05
SUS01L-09
SUS01M-09
SUS01N-09
SUS01O-09
DC OUTPUT VOLTAGE
5V
OUTPUT CURRENT RANGE
0 ~ 200mA
EFFICIENCY
73%
74%
72%
74%
75%
79%
80%
77%
SUS01L-12
SUS01M-12
SUS01N-12
SUS01O-12
SUS01L-15
SUS01M-15
SUS01N-15
SUS01O-15
ORDER NO.
9V
0 ~ 111mA
DC OUTPUT VOLTAGE
12V
15V
OUTPUT CURRENT RANGE
0 ~ 84mA
0 ~ 67mA
EFFICIENCY
78%
83%
83%
79%
82%
83%
83%
10.8 ~ 13.2V
12V
21.6 ~ 26.4V
24V
43.2 ~ 52.8V
48V
4.5 ~ 5.5V
5V
10.8 ~ 13.2V
12V
21.6 ~ 26.4V
24V
43.2 ~ 52.8V
48V
112mA
55mA
28mA
280mA
112mA
55mA
28mA
11mA
10mA
3mA
21mA
11mA
10mA
3mA
82%
SPECIFICATION
RATED POWER
1W
RIPPLE & NOISE (max.) Note.2 100mVp-p
LINE REGULATION
Note.3 1.2% for 1% input variation
LOAD REGULATION
Note.4 8.0%
VOLTAGE ACCURACY
50KHz min.
VOLTAGE RANGE
NORMAL VOLTAGE
4.5 ~ 5.5V
5V
INPUT CURRENT
INPUT
2.0%
SWITCHING FREQUENCY
Full load 280mA
No load 21mA
FILTER
Capacitor type
Fuse recommended
PROTECTION
Momentary
OVERLOAD
Protection type : Broken
Momentary
PROTECTION
SHORT CIRCUIT
Protection type : Broken
WORKING TEMP.
-25 ~ +71
WORKING HUMIDITY
20% ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
WITHSTAND VOLTAGE
SAFETY &
ISOLATION RESISTANCE
EMC
ISOLATION CAPACITANCE
MTBF
OTHERS
DIMENSION
-25 ~ +105
80pF max.
700khrs min. MIL-HDBK-217F(25 )
22.6*9.9*8.4mm or 0.89"*0.39"*0.33" inch (L*W*H)
Mechanical Specification
Unit: mm (inch)
Derating Curve
Pin Configuration
3.81 (0.15)
9.9 (0.39)
0.5 (0.02)
22.6 (0.89)
12.7 (0.50)
1
BOTTOM
VIEW
11
10
9
, 10 ~ 95% RH
0.03% / (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes
I/P-O/P:1KVDC
I/P-O/P: 100M Ohms / 500VDC / 25 / 70% RH
3.1g
WEIGHT
16
(Refer to output load derating curve)
6
7
8
Pin No.
Output
1 & 16
+Vin
6 & 11
7 & 10
-Vout
+Vout
8 & 9
-Vin
100
LOAD (%)
OUTPUT
80
2.54 (0.10)
7.62 (0.30)
NOTE
8.4 (0.33)
-25
0
25
50 60 71
100
Ta (
)
1.All parameters are specified at normal input, rated load, 25 70% RH ambient.
2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
3.Line regulation is measured from low line to high line at rated load.
4.Load regulation is measured from 20% to 100% rated load.
File Name: SUS01-SPEC 2008-05-08