TP-75 75W Triple Output with PFC Function series ■ Features : #Universal AC input / Full range #Built-in active PFC function, PF>0.95 #Protections: Short circuit / Overload / Over voltage #Low profile: 33mm thickness #LED indicator for power on #Cooling by free air convection #Fixed switching frequency at PFC:67KHz PWM:134KHz #3 years warranty .. SPECIFICATION MODEL OUTPUT TP-75A CH2 CH3 CH1 CH2 CH3 CH1 CH2 DC VOLTAGE 5V 12V -5V 5V 12V -12V 5V 15V -15V RATED CURRENT 7A 3A 0.6A 7A 3A 0.4A 6A 2.5A 0.5A CURRENT RANGE 1.5 ~ 10A 0.2 ~ 4A 0 ~ 0.6A 1.5 ~ 10A 0.2 ~ 4A 0 ~ 0.6A 1.5 ~ 10A 0.2 ~ 3A 0 ~ 0.6A RATED POWER 74W 120mVp-p 120mVp-p RIPPLE & NOISE (max.) Note.2 100mVp-p 120mVp-p 120mVp-p 100mVp-p ± 4.0% ± 8.0% ± 3.0% ± 4.0% ± 8.0% ± 3.0% ± 4.0% ± 8.0% ± 1.0% ± 1.0% ± 1.0% ± 1.0% ± 1.0% ± 1.0% ± 1.0% LOAD REGULATION ± 3.0% ± 4.0% ± 8.0% ± 3.0% ± 4.0% ± 8.0% ± 3.0% ± 4.0% ± 8.0% SETUP, RISE TIME 800ms, 60ms at full load 36ms at full load Note.5 90 ~ 264VAC 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.95/230VAC EFFICIENCY (Typ.) 70% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.5A/115VAC 0.8A/115VAC COLD START 20A/230VAC LEAKAGE CURRENT <2mA / 240VAC OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT NOTE 100mVp-p ± 1.0% PROTECTION OTHERS 100mVp-p ± 1.0% OVERLOAD (Note 4) 120mVp-p 75W VOLTAGE TOLERANCE Note.3 ± 3.0% VOLTAGE RANGE EMC 75.8W CH3 CH1: 4.75 ~ 5.5V VOLTAGE ADJ. RANGE HOLD UP TIME (Typ.) SAFETY & TP-75C CH1 LINE REGULATION INPUT TP-75B OUTPUT NUMBER PF>0.98/115VAC at full load 105 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 5.75 ~ 6.75V on +5V Protection type : Shut down o/p voltage, re-power on to recover -10 ~ +60℃ (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85℃, 10 ~ 95% RH ± 0.03%/ ℃ (0 ~ 50 ℃) VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC 1min. ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC Compliance to EN55022 (CISPR22) Class B EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY MTBF DIMENSION PACKING Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A 198.4K hrs min. MIL-HDBK-217F (25℃) 179*99*33mm (L*W*H) 0.65Kg; 20pcs/12.7Kg/0.64CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Derating may be needed under low input voltages. Please check the derating curve for more details. File Name:TP-75-SPEC 2007-10-25 TP-75 75W Triple Output with PFC Function series ■ Features : #Universal AC input / Full range #Built-in active PFC function, PF>0.95 #Protections: Short circuit / Overload/ Over voltage #Low profile: 33mm thickness #LED indicator for power on #Cooling by free air convection #Fixed switching frequency at PFC:67KHz PWM:134KHz #3 years warranty .. SPECIFICATION MODEL OUTPUT TP-75D CH1 CH2 CH3 CH1 CH2 CH3 DC VOLTAGE 5V 24V 12V 5V 3.3V 12V RATED CURRENT 7A 1.5A 0.4A 9A 8A 0.3A CURRENT RANGE 1.5 ~ 10A 0.2 ~ 2.5A 0 ~ 0.6A 1.5 ~ 10A 0.2 ~ 8A 0 ~ 0.6A RATED POWER 75.8W 50mVp-p 120mVp-p ± 8.0% RIPPLE & NOISE (max.) Note.2 100mVp-p 120mVp-p 100mVp-p VOLTAGE TOLERANCE Note.3 ± 3.0% ± 4.0% ± 8.0% ± 3.0% ± 4.0% ± 1.0% ± 1.0% ± 1.0% ± 1.0% ± 1.0% ± 1.0% LOAD REGULATION ± 3.0% ± 4.0% ± 8.0% ± 3.0% ± 4.0% ± 8.0% SETUP, RISE TIME 800ms, 60ms at full load 36ms at full load Note.5 90 ~ 264VAC 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR PF>0.95/230VAC EFFICIENCY (Typ.) 70% AC CURRENT INRUSH CURRENT (max.) 1.5A/115VAC 0.8A/115VAC COLD START 20A/230VAC LEAKAGE CURRENT <2mA / 240VAC OVERLOAD 105 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE EMC EMI CONDUCTION & RADIATION (Note 4) HARMONIC CURRENT EMS IMMUNITY MTBF DIMENSION PACKING NOTE 120mVp-p LINE REGULATION VOLTAGE RANGE OTHERS 75W CH1: 4.75 ~ 5.5V VOLTAGE ADJ. RANGE HOLD UP TIME (Typ.) INPUT TP-7503 OUTPUT NUMBER PF>0.98/115VAC at full load 5.75 ~ 6.75V on +5V Protection type : Shut down o/p voltage, re-power on to recover -10 ~ +60℃ (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85℃, 10 ~ 95% RH ± 0.03%/ ℃ (0 ~ 50 ℃) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC 1min. I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC Compliance to EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A 198.4K hrs min. MIL-HDBK-217F (25℃) 179*99*33mm (L*W*H) 0.65Kg; 20pcs/12.7Kg/0.64CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Derating may be needed under low input voltages. Please check the derating curve for more details. File Name:TP-75-SPEC 2007-10-25 TP-75 75W Triple Output with PFC Function Mechanical Specification Case No. 920A 60 series Unit:mm 65 LED 99 49.5 2-M4 L=4mm 16 7.62 6.15 1 2 3 4 5 6 7 8 119 +ADJ. 15 Terminal Pin No. Assignment 25 117 32.5 18 33 17 8 9 max. Pin No. 1 2,3 4 5 Assignment DC OUTPUT +V2 COM DC OUTPUT +V1 DC OUTPUT +V3 Pin No. 6 7 8 Assignment FG AC/N AC/L 6-M4 L=6mm 179 Block Diagram PFC fosc : 67KHz PWM fosc : 134KHz EMI FILTER & RECTIFIERS I/P PFC CIRCUIT RECTIFIERS & FILTER POWER SWITCHING FG O.L.P. +V -V CONSTANT CURRENT LIMITING & DETECTION CIRCUIT PWM & PFC CONTROL O.V.P. Derating Curve Output Derating VS Input Voltage Ta=25℃ With 18CFM Forced AIR 100 100 90 (15cm) 80 80 70 Convection LOAD (%) LOAD (%) 60 40 20 -10 0 10 20 30 40 50 AMBIENT TEMPERATURE (℃) 60 70 (HORIZONTAL) 60 50 40 85 100 115 125 155 230 264 INPUT VOLTAGE (VAC) 60Hz File Name:TP-75-SPEC 2007-10-25