MERRIMAC IDP-2S-500B

I&Q NETWORKS
IDP-2S Series
20 to 500 MHz / Two I&Q Phase Detectors with Common LO / Hermetic Package
PRINCIPAL SPECIFICATIONS
Model
Number
IDP-2S-***B
RF/LO Center
Frequency, f0
20 to 500 MHz
†
GENERAL SPECIFICATIONS
Bandwidth
MHz
10% of fo
†RF and video bandwidths are typically much greater than specified.
*** Insert center frequency in MHz.
Meri-Pac
 S-Package Outline
RF and LO Input Characteristics
Impedance:
50 Ω nom.
VSWR:
1.5:1 max.
RF Power Level:
0 dBm nom.
LO Power Level
+14 dBm nom.
I & Q Output Characteristics
Video Bandwidth: DC to †50 MHz nom.
Output Impedance: 50 Ω nom.
Conversion Loss
(RF to I or Q):
10 dB typ.
12 dB max.
IF Balance
Phase:
Amplitude:
Weight, nominal:
Operating Temp:
0 ± 5° max.
(I1 - I2 or Q1 - Q2)
90 ± 5° max.
(I1 - Q1 or I2 - Q2)
0.5 dB typ.,1 dB max.
0.35 oz (10 g)
-- 55° to +85°C
AVAILABLE OPTIONS
NOTES:
Phase Balance:
Amplitude Balance:
Wider Bandwidth:
1. Tolerance on 3 place decimals ± .010(.25 except as noted.
2. Dimensions in inches over millimeters.
3. Lead dimensions apply only at body.
4. All unmarked pins are case ground.
90° ± 2° max.
0.5 dB max.
Customized units
23Feb96
General Notes:
1. Dual I & Q networks are integrated devices that produce two pairs of quadrature-phased, equal amplitude
signals when fed by two IF signals and an LO signal as shown in the schematic above.
2. Merrimac’s IDP-2S series combines two matched circuits in one package. Both lumped and distributed
circuit technologies are used to minimize size and weight while maintaining excellent overall performance.
3. Merrimac’s I & Q networks comply with the relevant sections of MIL-M-28837 and may be screened for
compliance with additional specifications for military and space applications requiring the highest reliability.