MPD A835ERW

A800ERW Series
Low Cost, 8W DIP
Wide Input Range
DC/DC Converters
A
Budget
Saver!!
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
Input
Parameter
Conditions
5 VDC Input
12 VDC Input
24 VDC Input
48 VDC Input
• 8W Output Power
• 2:1 Input Voltage Range
Input Voltage Range
• 1,500 VDC Isolation
• -40ºC Operation
• Compact DIP Case
• Single & Dual Outputs
• 1.0 MH MTBF
• Industry Standard Pin-Out
• Lowest Cost!!
RoHS Compliant
Input Filter
Reverse Polarity Input Current
Short Circuit Input Power
Min.
4.5
9.0
18.0
36.0
Typ.
5.0
12.0
24.0
48.0
Max.
9.0
18.0
36.0
75.0
Units
1,000
1.0
3,000
A
mW
Max.
Units
%
%
%
%
%
mV P - P
%P-P
%
µSec
%
%/ºC
VDC
π (Pi) Filter
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation, Single Output
Load Regulation, Dual Output
Ripple & Noise (20 MHz) (Note 1)
Ripple & Noise (20 MHz)
Output Power Protection
Transient Recovery Time (Note 2)
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
Conditions
Min.
Dual Output , Balanced Loads
Vin = Min to Max
Iout = 25% to 100%
Iout = 25% to 100%
3.3 VDC, 5 VDC Output
All Other Outputs.
Typ.
±2.0
±2.0
±0.5
±0.5
±2.0
80
1
110
50% Load Step Change
±2.0
300
±6.0
±0.05
Typ.
Max.
Units
VDC
MΩ
pF
kHz
Max.
+75
+95
+115
Units
ºC
ºC
ºC
95
%
Continuous
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Conditions
60 Seconds
500 VDC
100 kHz, 1V
Min.
1,500
1,000
380
300
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Conditions
Min.
Typ.
-40
+25
-40
-40
Free Air Convection
RH, Non-condensing
Ambient
Case
Physical
Case Size
Case Material
Weight
1.25 x 0.80 x 0.50 Inches (31.8 x 20.3 x 12.7 mm)
Non-Conductive Black Plastic (UL94-V0)
0.56 Oz (16g)
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25ºC, Gnd Benign
Min.
Typ.
1.0
Max.
Units
MHours
Min.
-0.7
-0.7
-0.7
-0.7
Typ.
Max.
16.0
25.0
50.0
100.0
260
2,500
Units
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
Conditions
5 VDC Input
12 VDC Input
24 VDC Input
48 VDC Input
1.5 mm From Case For 10 Sec
All Models
VDC
ºC
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Model
Number
Input
Current (mA)
Voltage (VDC)
Nominal
Range
Full-Load
5
5
5
5
5
5
5
12
12
12
12
12
12
12
24
24
24
24
24
24
24
48
48
48
48
48
48
48
4.5 - 9.0
4.5 - 9.0
4.5 - 9.0
4.5 - 9.0
4.5 - 9.0
4.5 - 9.0
4.5 - 9.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
1430
2030
1920
1920
2030
1930
1930
666
833
775
775
813
775
775
321
397
387
387
397
387
387
160
198
194
194
198
194
194
Output
Reflected
Efficiency
Current
Ripple Voltage Current
(%, Typ)
(VDC) (mA, Max) (mA, Min)
No-Load Current
Fuse Rating
Slow-Blow
(mA)
(mA, Typ)
A801ERW
A802ERW
A803ERW
A804ERW
A805ERW
A806ERW
A807ERW
A811ERW
A812ERW
A813ERW
A814ERW
A815ERW
A816ERW
A817ERW
A821ERW
A822ERW
A823ERW
A824ERW
A825ERW
A826ERW
A827ERW
A831ERW
A832ERW
A833ERW
A834ERW
A835ERW
A836ERW
A837ERW
50
50
50
50
50
50
50
20
20
20
20
20
20
20
10
10
10
10
10
10
10
6
6
6
6
6
6
6
25
25
25
25
25
25
25
15
15
15
15
15
15
15
10
10
10
10
10
10
10
100
100
100
100
100
100
100
3.3
5.0
12.0
15.0
±5.0
±12.0
±15.0
3.3
5.0
12.0
15.0
±5.0
±12.0
±15.0
3.3
5.0
12.0
15.0
±5.0
±12.0
±15.0
3.3
5.0
12.0
15.0
±5.0
±12.0
±15.0
Notes:
1. When measuring output ripple, it is recommended that an external 0.47 µF
ceramic capacitor be placed from the +Vout pin to the -Vout pin for single
output units and from each output to common for dual output units. For
noise sensitive applications, the use of 3.3 µF capacitors will reduce the output
ripple.
2. Transient recovery is measured to within a 1% error band for a load step change
of 50% to 100%.
3. Operation at no-load will not damage these units. However, they may not meet
all specifications.
4. Dual output units may be connected to provide a 10 VDC, 24 VDC or 30 VDC
output. To do this, connect the load across the positive (+Vout) and negative
(-Vout) outputs and float the output common.
5. The converter should be connected to a low ac-impedance source. An input
source with a highly inductive impedance may affect the stability of the converter. In applications where the converter output loading is high and input
power is supplied over long lines, it may be necessary to use a capacitor on the
input to insure start-up.
In this case, it is recommended that a low ESR (ESR <1.0Ω at 100 kHz) capacitor
be mounted close to the converter. For 5V input units a 10 µF is recommended,
for 12V input units, a 3.3 µF; and for 24V & 48V units a 2.2 µF.
6. It is recommended that a fuse be used on the input of a power supply for
protection. See the table above for the correct rating.
1,600.0
1,600.0
660.0
530.0
±800.0
±330.0
±260.0
1,200.0
1,000.0
660.0
530.0
±800.0
±330.0
±260.0
1,200.0
1,000.0
660.0
530.0
±800.0
±330.0
±260.0
1,200.0
1,000.0
660.0
530.0
±800.0
±330.0
±260.0
60.0
50.0
25.0
20.0
±80.0
±33.5
±26.0
60.0
50.0
25.0
20.0
±80.0
±33.5
±26.0
60.0
50.0
25.0
20.0
±80.0
±33.5
±26.0
60.0
50.0
25.0
20.0
±80.0
±33.5
±26.0
74
79
83
83
79
82
82
75
80
86
86
82
86
86
78
84
86
86
84
86
86
78
84
86
86
84
86
86
4,000
4,000
4,000
4,000
4,000
4,000
4,000
2,000
2,000
2,000
2,000
2,000
2,000
2,000
1,000
1,000
1,000
1,000
1,000
1,000
1,000
500
500
500
500
500
500
500
Derating Curve
Mechanical Dimensions
Pin Connections
Pin
Single
Dual
Pin
Single
Dual
2, 3
9
11
-Vin
No Pin
NC
-Vin
Common
-Vout
14
16
22, 23
+Vout
-Vout
+Vin
+Vout
Common
+Vin
NC: No Connection
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
MicroPower Direct
www.micropowerdirect.com
292 Page Street, STE D, Stoughton, MA 02072
• TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]