MPD F2029ERW

F2000ERW Series
Low Cost, Compact
20W, 2:1 Input Range
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 20W Output Power
• 2:1 Input Voltage Range
• 1,500 VDC Isolation
• Single & Dual Outputs
• Efficiency to 86%
• Compact 1.6 x 2 In. Case
• -40°C to +71°C Operation
• Industry Standard Pin-Out
• Lowest Cost!!
Input
Parameter
Input Start Voltage
Input Filter
Short Circuit Input Power
Conditions
Min.
12 VDC Input
8.6
24 VDC Input 17.5
48 VDC Input 34.0
LC Filter
Typ.
8.8
17.8
35.0
Max.
9.0
18.0
36.0
3,500
Units
VDC
mW
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Output Power Protection
Transient Recovery Time (Note 4)
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
Conditions
Min.
Typ.
±1.0
Dual Output, Balanced Loads
±0.5
Vin = Min to Max
±0.2
Iout = 10% to 100%
±0.5
See Note 1
75
See Note 3 120
130
200
25% Load Step Change
±2.0
±0.02
Continuous (Autorecovery)
Max.
±3.0
±0.5
±1.0
150
150
300
±5.0
Units
%
%
%
%
mV P - P
%
µSec
%
%/°C
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Conditions
60 Seconds
500 VDC
100 kHz, 1V
Min.
1,500
500
Typ.
Max.
Units
VDC
M⍀
pF
kHz
Max.
+71
+105
Units
°C
°C
95
%
1,000
300
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Conditions
Ambient
Min.
Typ.
-40
+25
-50
Free Air Convection
RH, Non-condensing
Physical
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Case Size
Case Material
Weight
2.0 x 1.6 x 0.41 Inches (50.8 x 40.6 x 10.5 mm)
Metal With Non-Conductive Base (UL94-V0)
1.37 Oz (39g)
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
100
Typ.
Max.
Units
kHours
Conditions
12 VDC Input
24 VDC Input
48 VDC Input
1.5 mm From Case for 10 Sec
All Models
Min.
-0.7
-0.7
-0.7
Typ.
Max.
20.0
40.0
80.0
300
5,000
Units
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
VDC
°C
mW
www.micropowerdirect.com
Model Selection Guide
Model
Number
F2001ERW
F2002ERW
F2003ERW
F2004ERW
F2005ERW
F2006ERW
F2007ERW
F2008ERW
F2009ERW
F2011ERW
F2012ERW
F2013ERW
F2014ERW
F2015ERW
F2016ERW
F2017ERW
F2018ERW
F2019ERW
F2021ERW
F2022ERW
F2023ERW
F2024ERW
F2025ERW
F2026ERW
F2027ERW
F2028ERW
F2029ERW
Input
Voltage (VDC)
Nominal
Range
12
9.0 - 18.0
12
9.0 - 18.0
12
9.0 - 18.0
12
9.0 - 18.0
12
9.0 - 18.0
12
9.0 - 18.0
12
9.0 - 18.0
12
9.0 - 18.0
12
9.0 - 18.0
24
18.0 - 36.0
24
18.0 - 36.0
24
18.0 - 36.0
24
18.0 - 36.0
24
18.0 - 36.0
24
18.0 - 36.0
24
18.0 - 36.0
24
18.0 - 36.0
24
18.0 - 36.0
48
36.0 - 75.0
48
36.0 - 75.0
48
36.0 - 75.0
48
36.0 - 75.0
48
36.0 - 75.0
48
36.0 - 75.0
48
36.0 - 75.0
48
36.0 - 75.0
48
36.0 - 75.0
Current (mA)
Full-Load No-Load
1,937
40
2,109
40
2,057
40
2,032
40
2,008
40
2,083
40
2,032
40
2,032
40
2,008
40
968
20
1,028
20
1,004
20
980
20
968
20
1,028
20
968
20
968
20
968
20
479
10
502
10
496
10
496
10
484
10
514
10
484
10
484
10
484
10
Voltage
(VDC)
3.3
5.0
12.0
15.0
24.0
±5.0
±12.0
±15.0
±24.0
3.3
5.0
12.0
15.0
24.0
±5.0
±12.0
±15.0
±24.0
3.3
5.0
12.0
15.0
24.0
±5.0
±12.0
±15.0
±24.0
Output
Current
(mA, Max)
5,400
4,000
1,670
1,330
830
±2,000
±833
±666
±416
5,400
4,000
1,670
1,330
830
±2,000
±833
±666
±416
5,400
4,000
1,670
1,330
830
±2,000
±833
±666
±416
Notes:
1. When measuring output ripple, it is recommended that an external ceramic capacitor (approx 1 µF to
10 µF) be placed from the +Vout to the -Vout pins or single output units and from each output to common for
dual output units.
2. These converters are specified for operation
Input
Output
Vin
without external components. However, in some
Capacitor
Capacitor
applications the addition of input/ouput capacitors
will enhance stability and reduce output ripple.
12 VDC
100 µF
1,000 µF per 1A of Iout
Recommended capacitor values are given in the
24 VDC
100 µF
1,000 µF per 1A of Iout
table at right. For applications requiring very low
48 VDC
100 µF
1,000 µF per 1A of Iout
output noise levels, a simple LC filter should be
effective.
3. Overload protection is provided by a power limiting circuit. Long term operation under overload conditions
may cause damage to the unit.
4. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%.
5. These units should not be operated with a load under 10% of full load. Operation at no-load will not damage
the unit, but they may not meet all specifications.
6. A simple external circuit may be used to adjust the converter output. To adjust the output DOWN, connect a
5%, 3W resistor between the plus output pin and the Vout trim pin. To adjust the output UP, connect a 5%, 3W
resistor between the minus output pin and the Vout trim pin. For UP/Down trimming capability, connect a
10 kW potentiometer between the plus and minus outputs with the wiper arm connected to the Vout trim pin.
7. These units should not be operated over +71°C (see derating curve). Exceeding +71°C may damage the unit.
8. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection
table above for the correct rating.
Current
(mA, Min)
540
400
167
133
83
±200
±84
±67
±42
540
400
167
133
83
±200
±84
±67
±42
540
400
167
133
83
±200
±84
±67
±42
Efficiency
(%, Typ)
86
79
81
82
83
80
82
82
83
86
81
83
85
86
81
86
86
86
87
83
84
84
86
81
86
86
86
Overvoltage Capacitive Fuse Rating
Protection
Load
Slow-Blow
(VDC)
(µF Max.)
(mA)
4.29
13,000
4,000
6.5
6,800
4,000
15.6
2,200
4,000
19.5
755
4,000
31.2
500
4,000
±6.5
±3,400
4,000
±15.6
±680
4,000
±19.5
±450
4,000
±31.2
±220
4,000
4.29
13,000
2,000
6.5
6,800
2,000
15.6
2,200
2,000
19.5
755
2,000
31.2
500
2,000
±6.5
±3,400
2,000
±15.6
±680
2,000
±19.5
±450
2,000
±31.2
±220
2,000
4.29
13,000
1,000
6.5
6,800
1,000
15.6
2,200
1,000
19.5
755
1,000
31.2
500
1,000
±6.5
±3,400
1,000
±15.6
±680
1,000
±19.5
±450
1,000
±31.2
±220
1,000
Remote ON/OFF
Pin Connections
Parameter
Min
Max
Units
Supply On
0.5 40.0 or Open VDC
Supply Off
Grnd
<0.5
VDC
Control Common Referenced to Gnd
Remote ON/OFF Notes:
1. Maximum sink current at the on/off pin (pin 6) during a logic
low is 100 µA.
2. Maximum allowable leakage current of a switch connected to
the on/off terminal (Pin 6) at logic high (2.5V to 100V) is 5 µA.
Pin
1
2
4
5
6
7
8
Single Dual
+Vin
+Vin
-Vin
-Vin
Remote On/Off
No Pin +Vout
+Vout Comm.
-Vout
-Vout
Trim
Trim
Mechanical Dimensions
Derating Curve
MicroPower Direct
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]