B1500ERW Series Low Cost, 1 x 2 Inch 15W, 2:1 Input Range DC/DC Converters Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Key Features: • 15W Output Power • 2:1 Input Voltage Range Input Parameter Input Voltage Range • 1,500 VDC Isolation • Single & Dual Outputs • Efficiency to 87% • Compact 1 x 2 Inch Case • -40°C to +85°C Operation • Industry Standard Pin-Out • Lowest Cost!! Input Filter Short Circuit Input Power Conditions Min. 12 VDC Input 9.0 24 VDC Input 18.0 48 VDC Input 36.0 LC Filter Typ. 12.0 24.0 48.0 Max. 18.0 36.0 75.0 3,500 Units VDC mW Output Parameter Output Voltage Accuracy Output Trim Range Line Regulation Load Regulation Ripple & Noise (20 MHz) Output Power Protection Temperature Coefficient Output Short Circuit Conditions Min. Vin = Min to Max Iout = 10% to 100% Note 1 Typ. ±1.0 ±10 ±0.2 0.5 120 130 ±0.03 Continuous (Autorecovery) Max. ±3.0 ±0.5 1.0 150 150 Units % % % % mV P - P % %/°C General Parameter Isolation Voltage Isolation Resistance Isolation Capacitance Switching Frequency Conditions 60 Seconds 500 VDC 100 kHz, 1V Min. 1,500 500 Typ. Max. Units VDC MΩ pF kHz Max. +85 +125 Units °C °C 95 % 1,000 500 Environmental Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Conditions Min. Typ. -40 +25 -55 Free Air Convection RH, Non-condensing Ambient Physical MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Case Size Case Material Weight 2.0 x 1.0 x 0.44 Inches (50.8 x 25.4 x 11.2 mm) Metal With Non-Conductive Base (UL94-V0) 1.06 Oz (30g) Remote On/Off Parameter Unit On (Note 2) Unit Off (Note 2) Off Idle Current Conditions Min. 3.5 0 Typ. Max. 40.0 1.2 Units VDC VDC mA 5.0 Reliability Specifications Parameter MTBF Conditions MIL HDBK 217F, 25°C, Gnd Benign Min. 1.0 Typ. Max. Units MHours Conditions 12 VDC Input 24 VDC Input 48 VDC Input 1.5 mm From Case for 10 Sec All Models Min. -0.7 -0.7 -0.7 Typ. Max. 20.0 40.0 80.0 300 5,000 Units Absolute Maximum Ratings Parameter Input Voltage Surge (1 Sec) Lead Temperature Internal Power Dissipation VDC °C mW Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. Model Selection Guide Model Number B1501ERW B1502ERW B1503ERW B1504ERW B1505ERW B1506ERW B1511ERW B1512ERW B1513ERW B1514ERW B1515ERW B1516ERW B1521ERW B1522ERW B1523ERW B1524ERW B1525ERW B1526ERW Input Voltage (VDC) Current (mA) Nominal Range Full-Load No-Load 12 9.0 - 18.0 1,524 25 12 9.0 - 18.0 1,470 25 12 9.0 - 18.0 1,488 25 12 9.0 - 18.0 1,524 25 12 9.0 - 18.0 1,470 25 12 9.0 - 18.0 1,470 25 24 18.0 - 36.0 753 8 24 18.0 - 36.0 735 8 24 18.0 - 36.0 735 8 24 18.0 - 36.0 744 8 24 18.0 - 36.0 726 8 24 18.0 - 36.0 726 8 48 36.0 - 75.0 376 5 48 36.0 - 75.0 363 5 48 36.0 - 75.0 363 5 48 36.0 - 75.0 367 5 48 36.0 - 75.0 359 5 48 36.0 - 75.0 359 5 Voltage (VDC) 5 12 15 ±5 ±12 ±15 5 12 15 ±5 ±12 ±15 5 12 15 ±5 ±12 ±15 Notes: 1. When measuring output ripple, it is recommended that an external ceramic capacitor (approx 1 µF to 10 µF) be placed from the +Vout to the -Vout pins. 2. The remote On/Off control is referenced to ground. It is recommended that connection to the pin be made through a 1kΩ resistor and diode (1N4148). If it is not used, the control pin should be left open. 3. These units should not be operated with a load under 10% of full load. Operation at no-load will not damage the unit, but they may not meet all specifications. 4. These converters are specified for operation without external components. However, in some applications the addition of input/ouput capacitors will enhance stability and reduce output ripple. For applications requiring very low output noise levels, a simple LC filter should be effective. 5. These units should not be operated over +85°C (see derating curve). Exceeding +85°C may damage the unit. 6. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection table above for the correct rating. Output Current (mA, Max) 3,000 1,250 1,000 ±1,500 ±625 ±500 3,000 1,250 1,000 ±1,500 ±625 ±500 3,000 1,250 1,000 ±1,500 ±625 ±500 Current (mA, Min) 300 125 100 ±150 ±63 ±50 300 125 100 ±150 ±63 ±50 300 125 100 ±150 ±63 ±50 Efficiency (%, Typ) 82 85 84 82 85 85 83 85 85 84 86 86 83 86 86 85 87 87 Capacitive Fuse Rating Slow-Blow Load (mA) (µF, Max) 4,020 3,000 1,035 3,000 705 3,000 ±1,020 3,000 ±495 3,000 ±165 3,000 4,020 1,500 1,035 1,500 705 1,500 ±1,020 1,500 ±495 1,500 ±165 1,500 4,020 750 1,035 750 705 750 ±1,020 750 ±495 750 ±165 750 Derating Curve Mechanical Dimensions External Trim Pin Connections Pin 1 2 3 4 5 6 Single Dual +Vin +Vin -Vin -Vin +Vout +Vout Trim Common -Vout -Vout Remote On/Off Remote On/Off Mechanical Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) MicroPower Direct www.micropowerdirect.com 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 On single output units, a simple external circuit may be used to adjust the converter output. To adjust the output DOWN, connect a 5%, 3W resistor between the plus output pin and the Vout trim pin. To adjust the output UP, connect a 5%, 3W resistor between the minus output pin and the Vout trim pin. For UP/Down trimming capability, connect a 10 kW potentiometer between the plus and minus outputs with the wiper arm connected to the Vout trim pin. • E-Mail: [email protected]