MPD B1501ERW

B1500ERW Series
Low Cost, 1 x 2 Inch
15W, 2:1 Input Range
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 15W Output Power
• 2:1 Input Voltage Range
Input
Parameter
Input Voltage Range
• 1,500 VDC Isolation
• Single & Dual Outputs
• Efficiency to 87%
• Compact 1 x 2 Inch Case
• -40°C to +85°C Operation
• Industry Standard Pin-Out
• Lowest Cost!!
Input Filter
Short Circuit Input Power
Conditions
Min.
12 VDC Input
9.0
24 VDC Input 18.0
48 VDC Input 36.0
LC Filter
Typ.
12.0
24.0
48.0
Max.
18.0
36.0
75.0
3,500
Units
VDC
mW
Output
Parameter
Output Voltage Accuracy
Output Trim Range
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Output Power Protection
Temperature Coefficient
Output Short Circuit
Conditions
Min.
Vin = Min to Max
Iout = 10% to 100%
Note 1
Typ.
±1.0
±10
±0.2
0.5
120
130
±0.03
Continuous (Autorecovery)
Max.
±3.0
±0.5
1.0
150
150
Units
%
%
%
%
mV P - P
%
%/°C
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Conditions
60 Seconds
500 VDC
100 kHz, 1V
Min.
1,500
500
Typ.
Max.
Units
VDC
MΩ
pF
kHz
Max.
+85
+125
Units
°C
°C
95
%
1,000
500
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Conditions
Min.
Typ.
-40
+25
-55
Free Air Convection
RH, Non-condensing
Ambient
Physical
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Case Size
Case Material
Weight
2.0 x 1.0 x 0.44 Inches (50.8 x 25.4 x 11.2 mm)
Metal With Non-Conductive Base (UL94-V0)
1.06 Oz (30g)
Remote On/Off
Parameter
Unit On (Note 2)
Unit Off (Note 2)
Off Idle Current
Conditions
Min.
3.5
0
Typ.
Max.
40.0
1.2
Units
VDC
VDC
mA
5.0
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
1.0
Typ.
Max.
Units
MHours
Conditions
12 VDC Input
24 VDC Input
48 VDC Input
1.5 mm From Case for 10 Sec
All Models
Min.
-0.7
-0.7
-0.7
Typ.
Max.
20.0
40.0
80.0
300
5,000
Units
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
VDC
°C
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Model
Number
B1501ERW
B1502ERW
B1503ERW
B1504ERW
B1505ERW
B1506ERW
B1511ERW
B1512ERW
B1513ERW
B1514ERW
B1515ERW
B1516ERW
B1521ERW
B1522ERW
B1523ERW
B1524ERW
B1525ERW
B1526ERW
Input
Voltage (VDC)
Current (mA)
Nominal
Range
Full-Load No-Load
12
9.0 - 18.0
1,524
25
12
9.0 - 18.0
1,470
25
12
9.0 - 18.0
1,488
25
12
9.0 - 18.0
1,524
25
12
9.0 - 18.0
1,470
25
12
9.0 - 18.0
1,470
25
24
18.0 - 36.0
753
8
24
18.0 - 36.0
735
8
24
18.0 - 36.0
735
8
24
18.0 - 36.0
744
8
24
18.0 - 36.0
726
8
24
18.0 - 36.0
726
8
48
36.0 - 75.0
376
5
48
36.0 - 75.0
363
5
48
36.0 - 75.0
363
5
48
36.0 - 75.0
367
5
48
36.0 - 75.0
359
5
48
36.0 - 75.0
359
5
Voltage
(VDC)
5
12
15
±5
±12
±15
5
12
15
±5
±12
±15
5
12
15
±5
±12
±15
Notes:
1. When measuring output ripple, it is recommended that an external ceramic
capacitor (approx 1 µF to 10 µF) be placed from the +Vout to the -Vout pins.
2. The remote On/Off control is referenced to ground. It is recommended that
connection to the pin be made through a 1kΩ resistor and diode (1N4148).
If it is not used, the control pin should be left open.
3. These units should not be operated with a load under 10% of full load. Operation
at no-load will not damage the unit, but they may not meet all specifications.
4. These converters are specified for operation without external components. However, in some applications the addition of input/ouput capacitors will enhance
stability and reduce output ripple.
For applications requiring very low output noise levels, a simple LC filter should
be effective.
5. These units should not be operated over +85°C (see derating curve). Exceeding
+85°C may damage the unit.
6. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection table above for the correct rating.
Output
Current
(mA, Max)
3,000
1,250
1,000
±1,500
±625
±500
3,000
1,250
1,000
±1,500
±625
±500
3,000
1,250
1,000
±1,500
±625
±500
Current
(mA, Min)
300
125
100
±150
±63
±50
300
125
100
±150
±63
±50
300
125
100
±150
±63
±50
Efficiency
(%, Typ)
82
85
84
82
85
85
83
85
85
84
86
86
83
86
86
85
87
87
Capacitive Fuse Rating
Slow-Blow
Load
(mA)
(µF, Max)
4,020
3,000
1,035
3,000
705
3,000
±1,020
3,000
±495
3,000
±165
3,000
4,020
1,500
1,035
1,500
705
1,500
±1,020
1,500
±495
1,500
±165
1,500
4,020
750
1,035
750
705
750
±1,020
750
±495
750
±165
750
Derating Curve
Mechanical Dimensions
External Trim
Pin Connections
Pin
1
2
3
4
5
6
Single
Dual
+Vin
+Vin
-Vin
-Vin
+Vout
+Vout
Trim
Common
-Vout
-Vout
Remote On/Off Remote On/Off
Mechanical Notes:
• All dimensions are typical in
inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
On single output units, a simple external
circuit may be used to adjust the converter
output. To adjust the output DOWN, connect a 5%, 3W resistor between the plus
output pin and the Vout trim pin. To adjust
the output UP, connect a 5%, 3W resistor
between the minus output pin and the
Vout trim pin.
For UP/Down trimming capability, connect
a 10 kW potentiometer between the plus
and minus outputs with the wiper arm connected to the Vout trim pin.
•
E-Mail: [email protected]