MPD B3014RW

B3000RW Series
Compact 1 x 2 Inch 30W
Wide Input Range
DC/DC Con
verters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
Input
Parameter
• 30W Output Power
Input Start Voltage
• Compact 1 x 2 Inch Case
Input Undervoltage Shutdown
• 2:1 Input Voltage Range
• 1,500 VDC Isolation
• Optional Remote ON/OFF
• Overvoltage Protection
• Industry Standard Pin-Out
Input Overvoltage Shutdown
Input Filter
Reverse Polarity Input Current
Short Circuit Input Power
Conditions
Min.
Typ.
Max.
24 VDC Input 17.0
17.5
18.0
48 VDC Input 34.0
35.0
36.0
24 VDC Input 16.0
16.5
17.0
48 VDC Input 32.0
33.0
34.0
24 VDC Input 40.0
42.0
44.0
48 VDC Input 80.0
82.0
84.0
␲ (Pi) Filter (Complies with EN55022 Class “A”)
2.0
4,500
Units
VDC
VDC
VDC
A
mW
Output
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation, 2.5, 3.3, 5 Vout
Load Regulation, 12, 15 Vout
Ripple & Noise (20 MHz) (Note 1)
Ripple & Noise (20 MHz)
Ripple & Noise (20 MHz)
Output Power Protection
Transient Recovery Time (Note 2)
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
Conditions
Min.
Vin = Min to Max
Iout = 0% to 100%
Iout = 10% to 100%
Typ.
±0.5
±0.1
±0.5
±0.5
75
200
±2.0
±0.01
Max.
±1.0
±0.3
±1.0
±1.0
100
120
10
160
500
±5.0
±0.02
Units
%
%
%
%
mV P - P
mV P - P
mV rms
%
µSec
%
%/°C
Typ.
Max.
1,200
350
1,500
400
Units
VDC
VDC
M⍀
pF
kHz
Over Line, Load & Temp.
110
25% Load Step Change
Continuous
General
Parameter
Isolation Voltage
Isolation Test Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Remote On/Off (Note 3)
Parameter
Supply On
Supply Off
Standby Input Current
Control Common
Conditions
60 Seconds
Flash Tested For 1 Sec
500 VDC
100 kHz, 1V
Min.
1,500
1,650
1,000
280
Conditions
Min.
2.5
-1.0
Typ.
Max.
Units
100.0
VDC
1.0
VDC
5
mA
Referenced to Negative Input (pin 2)
Min.
-40
Typ.
+25
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
RFI
Physical
Case Size
Case Material
Weight
Conditions
Ambient
Case
-50
Free Air Convection
RH, Non-condensing
Six-Side Shielded Metal Case
Max.
+50
+105
+125
Units
°C
°C
°C
95
%
2.0 x 1.0 x 0.40 Inches (50.8 x 25.4 x 10.2 mm)
Metal with Non-Conductive Base (Anodized Black Aluminum)
1.13 Oz (32g)
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
600
Typ.
Max.
Units
kHours
Min.
-0.7
-0.7
Typ.
Max.
50.0
100.0
260.0
5,500
Units
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
Conditions
24 VDC Input
48 VDC Input
1.5 mm From Case For 10 Sec
All Models
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
VDC
°C
mW
www.micropowerdirect.com
Model Selection Guide
Output
Input
Model
Number
B3001RW
B3002RW
B3003RW
B3004RW
B3005RW
B3011RW
B3012RW
B3013RW
B3014RW
B3015RW
Voltage (VDC)
Nominal
Range
24
24
24
24
24
48
48
48
48
48
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
Over
Reflected
Capacitive Fuse Rating
Voltage
Efficiency
Ripple
Current (mA)
Load
Slow-Blow
Current Protection (%, Typ)
Current Voltage Current
(µF Max)
(mA)
Full-Load No-Load (mA, Typ) (VDC) (mA, Max) (mA, Min)
(VDC)
744
50
100
2.5
6,000.0
0.0
3.0
84
6,800
3,000
959
50
100
3.3
6,000.0
0.0
3.9
86
6,800
3,000
1,185
70
100
5.0
5,000.0
0.0
6.8
88
6,800
3,000
1,420
20
100
12.0
2,500.0
166.0
15.0
88
680
3,000
1,420
20
100
15.0
2,000.0
133.0
18.0
88
680
3,000
372
40
30
2.5
6,000.0
0.0
3.0
84
6,800
1,500
480
40
30
3.3
6,000.0
0.0
3.9
86
6,800
1,500
604
50
30
5.0
5,000.0
0.0
6.8
88
6,800
1,500
710
10
30
12.0
2,500.0
166.0
15.0
88
680
1,500
710
10
30
15.0
2,000.0
133.0
18.0
88
680
1,500
Mechanical Dimensions
For heatsink option, add suffix “H” to model number (i.e. B3003RU-H)
For Remote Control option, add suffix “R” to model number (i.e. B3003RU-R)
Notes:
1. When measuring output ripple, it is recommended that an external 1.0 µF ceramic capacitor
be placed from the +Vout pin to the -Vout pin.
2. Transient recovery is measured to within a 1% error band for a load step change of 75% to
100%.
3. The maximum control current at the on/off pin (pin 3) during a logic high is 5 µA. The maximum
control current to the on/off pin at logic low is -100 µA. If the on/off pin is left open, the unit operates.
If it is grounded, the unit will shut off.
4. Operation at no-load will not damage these units. However, they may not meet all specifications.
5. The converter should be connected to a low ac-impedance source. An input source with a
highly inductive impedance may affect the stability of the converter. In applications where
the converter output loading is high and input power is supplied over long lines, it may be
necessary to use a capacitor (such as a low ESR 10.0 µF) on the input to insure start-up.
6. It is recommended that a fuse be used on the input of a power supply for protection. See
the table above for the correct rating.
Pin
Connections
Pin Function
1
+Vin
2
-Vin
3 ON/OFF
4
+Vout
5
-Vout
6
Trim
External Trim
For continuous UP/Down trimming capability, connect a 10 kW potentiometer between the plus and minus outputs with the wiper arm connected to the VOUT trim pin. The trim pin may be left floating if it is not used.
An external resistor may also be used to adjust the converter output.
To adjust the output UP, connect a 5%, 3W resistor between the minus
output pin and the Vout trim pin. The output voltage is increased per
the equation:
RUP =
(33 x VOUT) - (30 x VADJ)
Mechanical Notes:
VADJ - VOUT
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
To adjust the output DOWN, connect a 5%, 3W resistor between the
plus output pin and the VOUT trim pin. The output voltage is decreased
per the equation:
RDwn =
(36.667 x VADJ) - (33 x VOUT)
VOUT - VADJ
Derating Curve
Heatsink Dimensions (Optional)
Where:
VOUT =
VADJ =
Units =
Nominal Output Voltage
Adjusted Output Volatage
VDC / k
MicroPower Direct
Heatsink Notes:
• Use of the heatsink will extend the units operating temperature
range by approximately 10°C.
• The heatsink is black anodized aluminum.
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]