H100I Series Ultra-Miniature MiniDIP 1W, High Isolation DC/DC Converters New Models!! Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Key Features: • 1W Output Power • Miniature MiniDIP Case • 3,000 VDC Isolation • Complies to RFI Standards • >2 MHour MTBF • 18 Standard Models • Industry Standard Pin-Out Input Parameter Conditions Input Voltage Range Input Filter Min. Typ. Max. 5 VDC Input 4.5 5.0 5.5 12 VDC Input 10.8 12.0 13.2 24 VDC Input 21.6 24.0 26.4 VDC Internal Capacitor Reverse Polarity Input Current 0.3 A Units Output Parameter Conditions Min. Typ. Max. ±1.0 ±3.0 % For Vin Change of 1% ±1.2 ±1.5 % Iout = 20% to 100% ±8.0 100 mV P - P ±0.02 %/ºC Max. Units Output Voltage Accuracy Line Regulation Load Regulation Ripple & Noise (20 MHz) Output Power Protection % 120 Temperature Coefficient RoHS Compliant Units % ±0.01 Output Short Circuit Momentary (0.5 Sec.) General Parameter Conditions Isolation Voltage Isolation Resistance Isolation Capacitance Min. 60 Seconds 3,000 500 VDC 1,000 100 kHz, 1V VDC MΩ 60 Switching Frequency EMI/RFI Typ. 100 pF 80 kHz EN55022 A, EN55024 A, IEC 61000-4-2, IEC 61000-4-3, FCC 47 CFR Part 15 B Environmental Parameter Conditions Operating Temperature Range Operating Temperature Range T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Max. +25 +85 ºC +100 ºC +125 ºC 95 % -40 Cooling 292 Page Street Ste D Stoughton, MA 02072 USA Typ. -40 Case Storage Temperature Range MicroPower Direct Min. Units Free Air Convection Humidity RH, Non-condensing Physical Case Size 0.50 x 0.40 x 0.27 Inches (12.70 x 10.16 x 6.85 mm) Case Material Non-Conductive Black Plastic (UL94-V0) Weight 0.06 Oz (1.8g) Reliability Specifications Parameter MTBF Conditions Min. MIL HDBK 217F, 25ºC, Gnd Benign Typ. Max. 2.0 Units MHours Absolute Maximum Ratings Parameter Input Voltage Surge (1 Sec) Lead Temperature Internal Power Dissipation Conditions Min. Typ. Max. 5 VDC Input -0.7 7.0 12 VDC Input -0.7 15.0 24 VDC Input -0.7 28.0 Units VDC 1.5 mm From Case For 10 Sec 260 ºC All Models 450 mW Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. Model Selection Guide Model Number H101I H102I H103I H104I H105I H106I H111I H112I H113I H114I H115I H116I H121I H122I H123I H124I H125I H126I Input Voltage (VDC) Current (mA) Nominal Range Full-Load No-Load 5 4.5 - 5.5 278 25 5 4.5 - 5.5 267 25 5 4.5 - 5.5 260 25 5 4.5 - 5.5 256 25 5 4.5 - 5.5 257 25 5 4.5 - 5.5 257 25 12 10.8 - 13.2 116 16 12 10.8 - 13.2 112 16 12 10.8 - 13.2 109 16 12 10.8 - 13.2 107 16 12 10.8 - 13.2 107 16 12 10.8 - 13.2 107 16 24 21.6 - 26.4 58 8 24 21.6 - 26.4 56 8 24 21.6 - 26.4 55 8 24 21.6 - 26.4 54 8 24 21.6 - 26.4 54 8 24 21.6 - 26.4 54 8 Other outputs are available. Contact the factory for details at: [email protected] Voltage (VDC) 3.3 5.0 9.0 12.0 15.0 24.0 3.3 5.0 9.0 12.0 15.0 24.0 3.3 5.0 9.0 12.0 15.0 24.0 Output Current (mA, Max) 300.0 200.0 111.0 83.3 66.6 41.6 300.0 200.0 111.0 83.3 66.6 41.6 300.0 200.0 111.0 83.3 66.6 41.6 Current (mA, Min) 5.0 4.0 2.0 2.0 2.0 2.0 5.0 4.0 2.0 2.0 2.0 2.0 5.0 4.0 2.0 2.0 2.0 2.0 Fuse Rating Slow-Blow (mA) 500 500 500 500 500 500 200 200 200 200 200 200 100 100 100 100 100 100 Efficiency (%, Typ) 72 75 77 78 78 78 72 75 77 78 78 78 72 75 77 78 78 78 Derating Curve Notes: 1. Output load regulation is specified for a load change of 20% to 100%. 2. When measuring output ripple, it is recommended that an external 0.33 µF ceramic capacitor be placed from the +Vout pin to the -Vout pin. 3. Operation at no-load will not damage these units. However, they may not meet all specifications. 4. The 5V, 12V and 24V input units do not require external components to operate, but the use of a low ESR capacitor (approximately 10 uF, ESR <1.0Ω at 100 kHz) mounted close to the converter input pins is recommended. For 48 VDC input units, an input capacitor should always be used. Dependent upon the application, a value between 4.7 µF and 47 uF should be sufficient. 5. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating. Mechanical Dimensions Capacitive Load (µF Max) 220 Pin Connections Pin Function 1 4 5 7 -Vin +Vin +Vout -Vout Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) • Pin 1 is marked by a “dot” or indentation on the top of the unit MicroPower Direct www.micropowerdirect.com 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]