MPD H106I

H100I Series
Ultra-Miniature MiniDIP
1W, High Isolation
DC/DC Converters
New Models!!
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 1W Output Power
• Miniature MiniDIP Case
• 3,000 VDC Isolation
• Complies to RFI Standards
• >2 MHour MTBF
• 18 Standard Models
• Industry Standard Pin-Out
Input
Parameter
Conditions
Input Voltage Range
Input Filter
Min.
Typ.
Max.
5 VDC Input
4.5
5.0
5.5
12 VDC Input
10.8
12.0
13.2
24 VDC Input
21.6
24.0
26.4
VDC
Internal Capacitor
Reverse Polarity Input Current
0.3
A
Units
Output
Parameter
Conditions
Min.
Typ.
Max.
±1.0
±3.0
%
For Vin Change of 1%
±1.2
±1.5
%
Iout = 20% to 100%
±8.0
100
mV P - P
±0.02
%/ºC
Max.
Units
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Output Power Protection
%
120
Temperature Coefficient
RoHS Compliant
Units
%
±0.01
Output Short Circuit
Momentary (0.5 Sec.)
General
Parameter
Conditions
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Min.
60 Seconds
3,000
500 VDC
1,000
100 kHz, 1V
VDC
MΩ
60
Switching Frequency
EMI/RFI
Typ.
100
pF
80
kHz
EN55022 A, EN55024 A, IEC 61000-4-2, IEC 61000-4-3, FCC 47 CFR Part 15 B
Environmental
Parameter
Conditions
Operating Temperature Range
Operating Temperature Range
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Max.
+25
+85
ºC
+100
ºC
+125
ºC
95
%
-40
Cooling
292 Page Street
Ste D
Stoughton, MA 02072
USA
Typ.
-40
Case
Storage Temperature Range
MicroPower Direct
Min.
Units
Free Air Convection
Humidity
RH, Non-condensing
Physical
Case Size
0.50 x 0.40 x 0.27 Inches (12.70 x 10.16 x 6.85 mm)
Case Material
Non-Conductive Black Plastic (UL94-V0)
Weight
0.06 Oz (1.8g)
Reliability Specifications
Parameter
MTBF
Conditions
Min.
MIL HDBK 217F, 25ºC, Gnd Benign
Typ.
Max.
2.0
Units
MHours
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
Conditions
Min.
Typ.
Max.
5 VDC Input
-0.7
7.0
12 VDC Input
-0.7
15.0
24 VDC Input
-0.7
28.0
Units
VDC
1.5 mm From Case For 10 Sec
260
ºC
All Models
450
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Model
Number
H101I
H102I
H103I
H104I
H105I
H106I
H111I
H112I
H113I
H114I
H115I
H116I
H121I
H122I
H123I
H124I
H125I
H126I
Input
Voltage (VDC)
Current (mA)
Nominal
Range
Full-Load
No-Load
5
4.5 - 5.5
278
25
5
4.5 - 5.5
267
25
5
4.5 - 5.5
260
25
5
4.5 - 5.5
256
25
5
4.5 - 5.5
257
25
5
4.5 - 5.5
257
25
12
10.8 - 13.2
116
16
12
10.8 - 13.2
112
16
12
10.8 - 13.2
109
16
12
10.8 - 13.2
107
16
12
10.8 - 13.2
107
16
12
10.8 - 13.2
107
16
24
21.6 - 26.4
58
8
24
21.6 - 26.4
56
8
24
21.6 - 26.4
55
8
24
21.6 - 26.4
54
8
24
21.6 - 26.4
54
8
24
21.6 - 26.4
54
8
Other outputs are available.
Contact the factory for details at:
[email protected]
Voltage
(VDC)
3.3
5.0
9.0
12.0
15.0
24.0
3.3
5.0
9.0
12.0
15.0
24.0
3.3
5.0
9.0
12.0
15.0
24.0
Output
Current
(mA, Max)
300.0
200.0
111.0
83.3
66.6
41.6
300.0
200.0
111.0
83.3
66.6
41.6
300.0
200.0
111.0
83.3
66.6
41.6
Current
(mA, Min)
5.0
4.0
2.0
2.0
2.0
2.0
5.0
4.0
2.0
2.0
2.0
2.0
5.0
4.0
2.0
2.0
2.0
2.0
Fuse Rating
Slow-Blow
(mA)
500
500
500
500
500
500
200
200
200
200
200
200
100
100
100
100
100
100
Efficiency
(%, Typ)
72
75
77
78
78
78
72
75
77
78
78
78
72
75
77
78
78
78
Derating Curve
Notes:
1. Output load regulation is specified for a load change of
20% to 100%.
2. When measuring output ripple, it is recommended that
an external 0.33 µF ceramic capacitor be placed from the
+Vout pin to the -Vout pin.
3. Operation at no-load will not damage these units. However, they may not meet all specifications.
4. The 5V, 12V and 24V input units do not require external
components to operate, but the use of a low ESR capacitor (approximately 10 uF, ESR <1.0Ω at 100 kHz) mounted
close to the converter input pins is recommended.
For 48 VDC input units, an input capacitor should always be
used. Dependent upon the application, a value between
4.7 µF and 47 uF should be sufficient.
5. It is recommended that a fuse be used on the input of a
power supply for protection. See the table above for the
correct rating.
Mechanical Dimensions
Capacitive
Load
(µF Max)
220
Pin Connections
Pin
Function
1
4
5
7
-Vin
+Vin
+Vout
-Vout
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
• Pin 1 is marked by a “dot” or indentation on the top
of the unit
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•