LF200S Datasheet - Micropower Direct

LF200S Series
Ultra-Miniature, 2W
Single Output SMT
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Key Features:
• 2W Output Power
• Ultra-Miniature SMT Case
• 1,000 VDC Isolation
• 5V, 12 & 24V Inputs
• -40ºC to +85ºC Operation
• 6 Standard Models
• 2.0 MH MTBF Minimum
• Industry Standard Pin-Out
Parameter
Conditions
5 VDC Input
12 VDC Input
24 VDC Input
Input Voltage Range
Reverse Polarity Input Current
Input Filter
Min.
Typ.
Max.
4.5
10.8
21.6
5.0
12.0
24.0
5.5
13.2
26.4
0.3
Units
VDC
A
Capacitor
Output
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation, See Note 1
Ripple & Noise (20 MHz)
Ripple & Noise (20 MHz)
Ripple & Noise (20 MHz)
Output Power Protection
Temperature Coefficient
Output Short Circuit
Conditions
Min.
Typ.
±1.5
For Vin Change of 1%
±1.2
See Model Selection Guide
See Note 2
50
Over Line, Load & Temp.
Max.
±4.0
±1.5
Units
%
%
75
150
5
mV P - P
mV P - P
mv rms
%
%/ºC
120
±0.01
Momentary (0.5 Sec.)
±0.02
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Conditions
60 Seconds
500 VDC
100 kHz, 1V
Min.
1,000
10
70
Typ.
Max.
60
100
100
120
Units
VDC
G
pF
kHz
Max.
+85
+90
+125
Units
ºC
ºC
ºC
95
%
Environmental
Parameter
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Conditions
Min.
Typ.
-40
+25
-40
-40
Free Air Convection
RH, Non-condensing
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Ambient
Case
0.50 x 0.36 x 0.34 Inches (12.7 x 9.3 x 8.7 mm)
Molding (UL94-V0)
0.05 Oz (1.5g)
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25ºC, Gnd Benign
Min.
2.0
Typ.
Max.
Typ.
Max.
Units
MHours
Absolute Maximum Ratings
Parameter
Conditions
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
5 VDC Input
12 VDC Input
24 VDC Input
1.5 mm From Case For 10 Sec.
All Models
Min.
-0.7
-0.7
-0.7
9.0
18.0
30.0
300
650
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Units
VDC
ºC
mW
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
LF201S
LF202S
LF211S
LF212S
LF221S
LF222S
Voltage (VDC)
Nominal
Range
5
5
12
12
24
24
4.5 - 5.5
4.5 - 5.5
10.8 - 13.2
10.8 - 13.2
21.6 - 26.4
21.6 - 26.4
Output
Current (mA)
Voltage
Full-Load No-Load (VDC)
519
488
213
201
106
101
60
60
30
30
15
15
Notes:
1. Load regulation is measured for an output change of 20% to 100%.
2. When measuring output ripple, it is recommended that an external 0.33
µF ceramic capacitor be placed from the +Vout pin to the -Vout pin. For
noise sensitive applications, the use of 1.5 µF capacitors will reduce
the output ripple.
3. Operation at no-load will not damage these units. However, they may
not meet all specifications.
4. The converter should be connected to a low ac-impedance source. An
input source with a highly inductive impedance may affect the stability
of the converter. In applications where the converter output loading is
high and input power is supplied over long lines, it may be necessary
to use a capacitor on the input to insure start-up.
In this case, it is recommended that a low ESR (ESR <1.0 at 100 kHz)
capacitor be mounted close to the converter. For 5V input units a 2.2 µF
is recommended, for 12V input units, a 1.0 µF and for 24V input models,
a 0.47 µF.
5. It is recommended that a fuse be used on the input of a power supply
for protection. See the table above for the correct rating.
Current
Current
Load
Regulation
(mA, Max)
(mA, Min)
(%, Max)
400.0
165.0
400.0
165.0
400.0
165.0
8.0
3.0
8.0
3.0
8.0
3.0
11
11
8
5
8
5
5.0
12.0
5.0
12.0
5.0
12.0
Output
Rating
Efficiency Capacitive Fuse
Slow-Blow
(%, Typ)
Load
(mA)
(µF, Max)
77
81
78
82
78
81
47
10
47
10
47
10
1,000
1,000
500
500
200
200
Derating Curve
Board Layout
Mechanical Dimensions
Pin Connections
Pin
Description
1
-Vin
2
+Vin
3
No Pin
4
-Vout
5
+Vout
6
No Pin
7
No Pin
8
NA
NA = Not for electrical connection
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
• Pin 1 is marked by a “dot” or indentation
on the unit
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]