MPD LF121SI

LF100SI Series
High Isolation, 1W
Single Output SMT
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Key Features:
• 1W Output Power
• Ultra-Miniature SMT Case
• 3,000 VDC Isolation
• 5V, 12V & 24V Inputs
• -40ºC to +85ºC Operation
• 9 Standard Models
• 2.0 MH MTBF Minimum
• Industry Standard Pin-Out
Parameter
Input Voltage Range
Conditions
Min.
Typ.
Max.
5 VDC Input
4.5
5.0
5.5
12 VDC Input
10.8
12.0
13.2
24 VDC Input
21.6
24.0
26.4
Reverse Polarity Input Current
Input Filter
VDC
0.3
A
Typ.
Max.
Units
±1.5
±4.0
%
±1.2
±1.5
%
100
mV P - P
150
mV P - P
5
mv rms
±0.02
%/ºC
Max.
Units
Capacitor
Output
Parameter
Conditions
Min.
Output Voltage Accuracy
Line Regulation
Load Regulation (Note 1)
For Vin Change of 1%
See Model Selection Guide
Ripple & Noise (20 MHz) (Note 2)
Ripple & Noise (20 MHz)
75
Over Line, Load & Temp.
Ripple & Noise (20 MHz)
Output Power Protection
120
Temperature Coeiffcient
%
±0.01
Output Short Circuit
RoHS Compliant
Units
Momentary (0.5 Sec.)
General
Parameter
Conditions
Isolation Voltage
Min.
60 Seconds
Isolation Resistance
500 VDC
Isolation Capacitance
VDC
10
100 kHz, 1V
Switching Frequency
Typ.
3,000
GΩ
60
100
pF
50
100
150
kHz
Min.
Typ.
Max.
Units
+25
Environmental
Parameter
Conditions
Operating Temperature Range
Ambient
-40
+85
ºC
Operating Temperature Range
Case
-40
+90
ºC
-40
+125
ºC
95
%
Storage Temperature Range
Cooling
MicroPower Direct
Humidity
292 Page Street
Suite D
Stoughton, MA 02072
USA
Physical
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Reliability Specifications
Free Air Convection
RH, Non-condensing
Case Size
0.60 x 0.31 x 0.26 Inches (15.24 x 8.0 x 6.7 mm)
Case Material
Molded Black Plastic (UL94-V0)
Weight
Parameter
MTBF
0.07 Oz (2.2g)
Conditions
Min.
MIL HDBK 217F, 25ºC, Gnd Benign
2.0
Conditions
Min.
Typ.
Max.
Units
MHours
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
Typ.
Max.
5 VDC Input
-0.7
9.0
12 VDC Input
-0.7
18.0
24 VDC Input
-0.7
30.0
Units
VDC
1.5 mm From Case For 10 Sec.
300
ºC
All Models
550
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Input
Model
Number
Voltage (VDC)
Output
Load
Voltage Current
Current Regulation
Full-Load No-Load (VDC) (mA, Max) (mA, Min) (%, Max)
Current (mA)
Efficiency
(%, Typ)
Fuse Rating
Slow-Blow
(mA)
Nominal
Range
LF101SI
5
4.5 - 5.5
281
30
5.0
200.0
4.0
10
71
500
LF102SI
5
4.5 - 5.5
258
30
12.0
84.0
1.5
7
78
500
LF103SI
5
4.5 - 5.5
258
30
15.0
67.0
1.0
7
78
500
LF111SI
12
10.8 - 13.2
117
12
5.0
200.0
4.0
8
71
200
LF112SI
12
10.8 - 13.2
106
12
12.0
84.0
1.5
5
79
200
LF113SI
12
10.8 - 13.2
104
12
15.0
67.0
1.0
5
80
200
LF121SI
24
21.6 - 26.4
58
7
5.0
200.0
4.0
8
71
100
LF122SI
24
21.6 - 26.4
53
7
12.0
84.0
1.5
5
78
100
LF123SI
24
21.6 - 26.4
53
7
15.0
67.0
1.0
5
79
100
Notes:
1. Load regulation is measured for an output change of 20%
to 100%.
2. When measuring output ripple, it is recommended that an
external 0.33 µF ceramic capacitor be placed from the +Vout
pin to the -Vout pin. For noise sensitive applications, the use
of 0.47 µF capacitors will reduce the output ripple.
3. Operation at no-load will not damage these units. However,
they may not meet all specifications.
4. The converter should be connected to a low ac-impedance
source. An input source with a highly inductive impedance
may affect the stability of the converter. In applications where
the converter output loading is high and input power is supplied over long lines, it may be necessary to use a capacitor
on the input to insure start-up.
In this case, it is recommended that a low ESR (ESR <1.0Ω at
100 kHz) capacitor be mounted close to the converter. For
5V input units a 2.2 µF is recommended, for 12V input units,
a 1.0 µF, and for 24V input units, a 0.47 µF.
5. It is recommended that a fuse be used on the input of a
power supply for protection. See the table above for the
correct rating.
Derating Curve
Mechanical Dimensions
Board Layout
Pin Connections
Pin
Description
Pin
Description
1
-Vin
7
NA
2
+Vin
8
+Vout
3
NA
10
NA
5
-Vout
11
NA
6
NA
12
NA
NA = Not available for connection
Capacitive Load
MicroPower Direct
5V Out
µF Max
12 & 15V Out
µF Max
33
4.7
Notes:
• All dimensions are typical in inches (mm)
• Tolerance: Inches x.xx = ±0.01
Millimeters x.x = ±0.25
x.xx = ±0.13
Pin: ±0.002 (±0.05)
• Pin 1 is mark
marked by a “dot” or indentation
on the unit. T
The curved edge of the case
indicates the Pin 1 side.
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]