LF200D Datasheet - Micropower Direct

LF200D Series
Ultra-Miniature, 2W
Dual Output SMT
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
Input
• 2W Output Power
• Ultra-Miniature SMT Case
• 1,000 VDC Isolation
• 5V, 12 & 24V Inputs
• -40ºC to +85ºC Operation
• 7 Standard Models
• 2.0 MH MTBF Minimum
• Industry Standard Pin-Out
Parameter
Conditions
5 VDC Input
12 VDC Input
24 VDC Input
Input Voltage Range
Reverse Polarity Input Current
Input Filter
Min.
4.5
10.8
21.6
Typ.
5.0
12.0
24.0
Max.
5.5
13.2
26.4
0.3
Units
Max.
±4.0
±1.0
±1.5
Units
%
%
%
75
150
5
mV P - P
mV P - P
mv rms
%
%/ºC
VDC
A
Capacitor
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation, See Note 1
Ripple & Noise (20 MHz)
Ripple & Noise (20 MHz)
Ripple & Noise (20 MHz)
Output Power Protection
Temperature Coefficient
Output Short Circuit
Conditions
Min.
Typ.
±1.5
Dual Output, Balanced Load
±0.1
For Vin Change of 1%
±1.2
See Model Selection Guide
See Note 2
50
Over Line, Load & Temp.
120
±0.01
Momentary (0.5 Sec.)
±0.02
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Conditions
60 Seconds
500 VDC
100 kHz, 1V
Min.
1,000
10
70
Typ.
Max.
60
100
100
120
Units
VDC
G
pF
kHz
Max.
+85
+90
+125
Units
ºC
ºC
ºC
95
%
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Conditions
Min.
Typ.
-40
+25
-40
-40
Free Air Convection
RH, Non-condensing
Ambient
Case
0.60 x 0.36 x 0.34 Inches (15.3 x 9.3 x 8.7 mm)
Molding (UL94-V0)
0.07 Oz (2.2g)
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25ºC, Gnd Benign
Min.
2.0
Typ.
Max.
Units
MHours
Min.
-0.7
-0.7
-0.7
Typ.
Max.
9.0
18.0
30.0
300
650
Units
Absolute Maximum Ratings
Parameter
Conditions
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
5 VDC Input
12 VDC Input
24 VDC Input
1.5 mm From Case For 10 Sec.
All Models
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
VDC
ºC
mW
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
LF201D
LF202D
LF203D
LF212D
LF213D
LF222D
LF223D
Voltage (VDC)
Nominal
Range
5
5
5
12
12
24
24
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
10.8 - 13.2
10.8 - 13.2
21.6 - 26.4
21.6 - 26.4
Output
Current (mA)
Voltage
Full-Load No-Load (VDC)
519
504
501
202
201
102
100
60
60
60
30
30
15
15
±5.0
±12.0
±15.0
±12.0
±15.0
±12.0
±15.0
Notes:
1. Load regulation is measured for an output change of 20% to 100%.
2. When measuring output ripple, it is recommended that an external 0.33
µF ceramic capacitor be placed from each output to common. For noise
sensitive applications, the use of 1.5 µF capacitors will reduce the output
ripple.
3. Operation at no-load will not damage these units. However, they may not
meet all specifications.
4. The converter should be connected to a low ac-impedance source. An
input source with a highly inductive impedance may affect the stability of
the converter. In applications where the converter output loading is high
and input power is supplied over long lines, it may be necessary to use a
capacitor on the input to insure start-up.
In this case, it is recommended that a low ESR (ESR <1.0 at 100 kHz)
capacitor be mounted close to the converter. For 5V input units a 2.2 µF is
recommended, for 12V input units, a 1.0 µF and for 24V input units a 4.7
µF.
5. The outputs of these units may be connected to provide a 10 VDC, 24 VDC
or 30 VDC output. To do this, connect the load across the positive (+Vout)
and negative (-Vout) ouputs and float the ouput common.
6. It is recommended that a fuse be used on the input of a power supply for
protection. See the table above for the correct rating.
Current
Current
Load
Regulation
(mA, Max)
(mA, Min)
(%, Max)
±4.0
±1.5
±1.0
±1.5
±1.0
±1.5
±1.0
10
7
7
5
5
5
5
±200.0
±83.0
±66.0
±83.0
±66.0
±83.0
±66.0
Output
Rating
Efficiency Capacitive Fuse
Slow-Blow
(%, Typ)
Load
(mA)
(µF, Max)
77
79
79
82
82
81
82
±10
±4.7
±4.7
±4.7
±4.7
±4.7
±4.7
1,000
1,000
1,000
500
500
200
200
Derating Curve
Mechanical Dimensions
Pin Connections
Pin Description
Pin Description
1
-Vin
6
No Pin
2
+Vin
7
+Vout
3
No Pin
8
No Pin
4
Common
9
No Pin
5
-Vout
10
NA
NA = Not for electrical connection
Board Layout
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
• Pin 1 is marked by a “dot” or indentation on the unit
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]