MPD LF212D

LF200D Series
Ultra-Miniature, 2W
Dual Output SMT
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
Input
• 2W Output Power
Parameter
• Ultra-Miniature SMT Case
Input Voltage Range
• 1,000 VDC Isolation
• 5V, 12 & 24V Inputs
• -40ºC to +85ºC Operation
Reverse Polarity Input Current
Input Filter
• 7 Standard Models
Output
• 2.0 MH MTBF Minimum
• Industry Standard Pin-Out
RoHS Compliant
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation (Note 1)
Ripple & Noise (20 MHz) (Note 2)
Ripple & Noise (20 MHz)
Ripple & Noise (20 MHz)
Output Power Protection
Temperature Coefficient
Output Short Circuit
Conditions
5 VDC Input
12 VDC Input
24 VDC Input
Min.
4.5
10.8
21.6
Typ.
5.0
12.0
24.0
Max.
5.5
13.2
26.4
0.3
Units
Max.
±4.0
±1.0
±1.5
Units
%
%
%
75
150
5
mV P - P
mV P - P
mv rms
%
%/ºC
VDC
A
Capacitor
Conditions
Min.
Typ.
±1.5
Dual Output, Balanced Load
±0.1
For Vin Change of 1%
±1.2
See Model Selection Guide
50
Over Line, Load & Temp.
120
±0.01
Momentary (0.5 Sec.)
±0.02
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Conditions
60 Seconds
500 VDC
100 kHz, 1V
Min.
1,000
10
70
Typ.
Max.
60
100
100
120
Units
VDC
GΩ
pF
kHz
Max.
+85
+90
+125
Units
ºC
ºC
ºC
95
%
Environmental
MicroPower Direct
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
292 Page Street
Suite D
Stoughton, MA 02072
USA
Physical
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Reliability Specifications
Conditions
Min.
Typ.
-40
+25
-40
-40
Free Air Convection
RH, Non-condensing
Ambient
Case
Case Size
Case Material
Weight
Parameter
MTBF
0.60 x 0.36 x 0.34 Inches (15.3 x 9.3 x 8.7 mm)
Molding (UL94-V0)
0.07 Oz (2.2g)
Conditions
MIL HDBK 217F, 25ºC, Gnd Benign
Min.
2.0
Typ.
Max.
Units
MHours
Conditions
Min.
-0.7
-0.7
-0.7
Typ.
Max.
9.0
18.0
30.0
300
650
Units
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
5 VDC Input
12 VDC Input
24 VDC Input
1.5 mm From Case For 10 Sec.
All Models
VDC
ºC
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Input
Output
Load
Voltage (VDC)
Current (mA)
Voltage Current
Current Regulation
Nominal
Range
Full-Load No-Load (VDC) (mA, Max) (mA, Min) (%, Max)
5
4.5 - 5.5
519
60
±5.0
±200.0
±4.0
10
5
4.5 - 5.5
504
60
±12.0
±83.0
±1.5
7
5
4.5 - 5.5
501
60
±15.0
±66.0
±1.0
7
12
10.8 - 13.2
202
30
±12.0
±83.0
±1.5
5
12
10.8 - 13.2
201
30
±15.0
±66.0
±1.0
5
24
21.6 - 26.4
102
15
±12.0
±83.0
±1.5
5
24
21.6 - 26.4
100
15
±15.0
±66.0
±1.0
5
Model
Number
LF201D
LF202D
LF203D
LF212D
LF213D
LF222D
LF223D
Notes:
1. Load regulation is measured for an output change of 20% to
100%.
2. When measuring output ripple, it is recommended that an external
0.33 μF ceramic capacitor be placed from each output to common.
For noise sensitive applications, the use of 1.5 μF capacitors will
reduce the output ripple.
3. Operation at no-load will not damage these units. However, they
may not meet all specifications.
4. The converter should be connected to a low ac-impedance source.
An input source with a highly inductive impedance may affect the
stability of the converter. In applications where the converter output
loading is high and input power is supplied over long lines, it may
be necessary to use a capacitor on the input to insure start-up.
In this case, it is recommended that a low ESR (ESR <1.0Ω at 100 kHz)
capacitor be mounted close to the converter. For 5V input units a
2.2 μF is recommended, for 12V input units, a 1.0 μF and for 24V
input units a 4.7 μF.
5. The outputs of these units may be connected to provide a 10 VDC,
24 VDC or 30 VDC output. To do this, connect the load across the
positive (+Vout) and negative (-Vout) ouputs and float the ouput
common.
6. It is recommended that a fuse be used on the input of a power
supply for protection. See the table above for the correct rating.
±5 VDC
μF Max
77
79
79
82
82
81
82
Fuse Rating
Slow-Blow
(mA)
1,000
1,000
1,000
500
500
200
200
Derating Curve
Mechanical Dimensions
Capacitive Load
Output
Efficiency
(%, Typ)
±12 & ±15 VDC
±10 μF
±4.7 μF
Pin Connections
Pin
Description
Pin
Description
1
-Vin
6
No Pin
2
+Vin
7
+Vout
3
No Pin
8
No Pin
4
Common
9
No Pin
5
-Vout
10
NA
NA = Not for electrical connection
Board Layout
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
• Pin 1 is marked by a “dot” or indentation on the unit
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]