LF200D Series Ultra-Miniature, 2W Dual Output SMT DC/DC Converters Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Key Features: Input • 2W Output Power Parameter • Ultra-Miniature SMT Case Input Voltage Range • 1,000 VDC Isolation • 5V, 12 & 24V Inputs • -40ºC to +85ºC Operation Reverse Polarity Input Current Input Filter • 7 Standard Models Output • 2.0 MH MTBF Minimum • Industry Standard Pin-Out RoHS Compliant Parameter Output Voltage Accuracy Output Voltage Balance Line Regulation Load Regulation (Note 1) Ripple & Noise (20 MHz) (Note 2) Ripple & Noise (20 MHz) Ripple & Noise (20 MHz) Output Power Protection Temperature Coefficient Output Short Circuit Conditions 5 VDC Input 12 VDC Input 24 VDC Input Min. 4.5 10.8 21.6 Typ. 5.0 12.0 24.0 Max. 5.5 13.2 26.4 0.3 Units Max. ±4.0 ±1.0 ±1.5 Units % % % 75 150 5 mV P - P mV P - P mv rms % %/ºC VDC A Capacitor Conditions Min. Typ. ±1.5 Dual Output, Balanced Load ±0.1 For Vin Change of 1% ±1.2 See Model Selection Guide 50 Over Line, Load & Temp. 120 ±0.01 Momentary (0.5 Sec.) ±0.02 General Parameter Isolation Voltage Isolation Resistance Isolation Capacitance Switching Frequency Conditions 60 Seconds 500 VDC 100 kHz, 1V Min. 1,000 10 70 Typ. Max. 60 100 100 120 Units VDC GΩ pF kHz Max. +85 +90 +125 Units ºC ºC ºC 95 % Environmental MicroPower Direct Parameter Operating Temperature Range Operating Temperature Range Storage Temperature Range Cooling Humidity 292 Page Street Suite D Stoughton, MA 02072 USA Physical T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Reliability Specifications Conditions Min. Typ. -40 +25 -40 -40 Free Air Convection RH, Non-condensing Ambient Case Case Size Case Material Weight Parameter MTBF 0.60 x 0.36 x 0.34 Inches (15.3 x 9.3 x 8.7 mm) Molding (UL94-V0) 0.07 Oz (2.2g) Conditions MIL HDBK 217F, 25ºC, Gnd Benign Min. 2.0 Typ. Max. Units MHours Conditions Min. -0.7 -0.7 -0.7 Typ. Max. 9.0 18.0 30.0 300 650 Units Absolute Maximum Ratings Parameter Input Voltage Surge (1 Sec) Lead Temperature Internal Power Dissipation 5 VDC Input 12 VDC Input 24 VDC Input 1.5 mm From Case For 10 Sec. All Models VDC ºC mW Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. Model Selection Guide Input Output Load Voltage (VDC) Current (mA) Voltage Current Current Regulation Nominal Range Full-Load No-Load (VDC) (mA, Max) (mA, Min) (%, Max) 5 4.5 - 5.5 519 60 ±5.0 ±200.0 ±4.0 10 5 4.5 - 5.5 504 60 ±12.0 ±83.0 ±1.5 7 5 4.5 - 5.5 501 60 ±15.0 ±66.0 ±1.0 7 12 10.8 - 13.2 202 30 ±12.0 ±83.0 ±1.5 5 12 10.8 - 13.2 201 30 ±15.0 ±66.0 ±1.0 5 24 21.6 - 26.4 102 15 ±12.0 ±83.0 ±1.5 5 24 21.6 - 26.4 100 15 ±15.0 ±66.0 ±1.0 5 Model Number LF201D LF202D LF203D LF212D LF213D LF222D LF223D Notes: 1. Load regulation is measured for an output change of 20% to 100%. 2. When measuring output ripple, it is recommended that an external 0.33 μF ceramic capacitor be placed from each output to common. For noise sensitive applications, the use of 1.5 μF capacitors will reduce the output ripple. 3. Operation at no-load will not damage these units. However, they may not meet all specifications. 4. The converter should be connected to a low ac-impedance source. An input source with a highly inductive impedance may affect the stability of the converter. In applications where the converter output loading is high and input power is supplied over long lines, it may be necessary to use a capacitor on the input to insure start-up. In this case, it is recommended that a low ESR (ESR <1.0Ω at 100 kHz) capacitor be mounted close to the converter. For 5V input units a 2.2 μF is recommended, for 12V input units, a 1.0 μF and for 24V input units a 4.7 μF. 5. The outputs of these units may be connected to provide a 10 VDC, 24 VDC or 30 VDC output. To do this, connect the load across the positive (+Vout) and negative (-Vout) ouputs and float the ouput common. 6. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating. ±5 VDC μF Max 77 79 79 82 82 81 82 Fuse Rating Slow-Blow (mA) 1,000 1,000 1,000 500 500 200 200 Derating Curve Mechanical Dimensions Capacitive Load Output Efficiency (%, Typ) ±12 & ±15 VDC ±10 μF ±4.7 μF Pin Connections Pin Description Pin Description 1 -Vin 6 No Pin 2 +Vin 7 +Vout 3 No Pin 8 No Pin 4 Common 9 No Pin 5 -Vout 10 NA NA = Not for electrical connection Board Layout Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) • Pin 1 is marked by a “dot” or indentation on the unit MicroPower Direct www.micropowerdirect.com 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]