MPD MPA321

MPA321 Series
Smallest 1U Height,
Only
320W, Active PFC
6 x 4 x 1.5
Inches!!
Single Output
AC/DC Power Supplies
Key Features:
Electrical Specifications
• Smallest 1U 320W Supply
• PFC to EN61000-3-2 “D”
• UL, cUL, TUV Approvals
• CE Certified
• FCC Class B Emissions
• 2 - 60 V Output Voltages
• Universal 90-264 VAC Input
• 700W Peak Power
• Four Mechanical Options
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Input Voltage Range
Input Frequency
Input Current, Full Load
Inrush Current, Cold Start
Leakage Current
Power Factor Correction
Input Protection
Conditions
Universal
Min.
90
47
Typ.
90 VAC
6
110 VAC
220 VAC
240 VAC
3.5
Meets EN61000-3-2 Class D
T6A/250V Fuse
Max.
264
63
30
70
Units
VAC
Hz
A
A
mA
Output
Parameter
Output Voltage Adjustment
Output Regulation (Note 1)
Hold Time
Ripple & Noise (20 MHz) (Note 2)
Overload Protection
Over Voltage Protection
Over Temperature Protection
Temperature Coefficient
Transient Recovery Time (Note 3)
Transient Response Deviation
Overshoot/Undershoot
Turn On Delay
Output Short Circuit
Conditions
Min.
Typ.
Max.
±5.0
±1.0
110 VAC, 80% Load
20
See Model Selection Guide
Foldback (Autorecovery)
110
140
>130% of Rated Output Voltage. Recycle AC Input.
Operating Ambient (Autorecovery)
90
100
±0.04
2.5
50% Load Change
5
At Turn On/Off
5.0
120 VAC
1
Continuous With Autorecovery
By Trim Pot
Units
%
%
mSec
%
ºC
%/ºC
mS
%
%
S
General
Parameter
Isolation Voltage (Note 4)
Switching Frequency
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Conditions
Input - Output
Input - FG (Frame Ground)
Primary - Core
Fixed
Min.
3,000
1,500
1,500
Typ.
Max.
Units
VAC
23
kHz
Interface Signals
Power Supply On
Power Good Signal
Fan Fail
Green LED (LED1) on the PCB
PG on CN1. Goes TTL high 100 to 500 mS after regulation. Goes low at
least 1 mS before the loss of regulation. Will sink 100 mA.
FF on pin 3 of CN1. Open collector output rated for 15 VDC/5 mA sink
current maximum. Goes high if a fan failure is detected
Environmental
Parameter
Operating Temperature Range
Output Derating
Storage Temperature Range
Cooling
Operating Humidity
Conditions
Min.
Typ.
Max.
Ambient
0
+25
+50
2.5%/ ºC from +50 ºC to + 70 ºC
-20
+85
See Model Selection Guide
RH, Non-condensing
90
Units
ºC
ºC
%
Reliability Specifications
Parameter
MTBF
Safety Standards
EEMI Compliance
EMS Immunity Compliance
Conditions
Min.
Typ.
Max.
Units
MIL HDBK 217F, 30ºC, Gnd Benign
100
kHours
UL 60950; CSA C22.2 No. 60950; TUV EN60950; CB Report (IEC 60950)
Compliance to EN55022 (CISPR22) Class B; EN61000-3-2,3
EN6100-4-2,3,4,5,6,8,11; EN55024,; CE Marked (LVD)
Model Selection Guide
Model
Number
MPA321x-05z
MPA321x-09z
MPA321x-12z
MPA321x-15z
MPA321x-18z
MPA321x-24z
MPA321x-28z
MPA321x-36z
MPA321x-48z
MPA321x-54z
Output Voltage
Factory
Range
PreSet
5 VDC
2.0 - 6.0 VDC
9 VDC
7.0 - 9.0 VDC
12 VDC 10.0 - 13.8 VDC
15 VDC 14.0 - 15.5 VDC
18 VDC 16.0 - 20.0 VDC
24 VDC 21.0 - 26.0 VDC
28 VDC 27.0 - 34.0 VDC
36 VDC 35.0 - 42.0 VDC
48 VDC 43.0 - 50.0 VDC
54 VDC 51.0 - 60.0 VDC
Max. Output Current (Notes 6, 7, 8)
Ripple &
“U, E, F” Units “U” Units
“C” Units
Noise
28.5 CFM
Convection Convection
45.00A
26.00A
23.70A
50 mV p-p
35.50A
20.00A
18.75A
1% p-p
26.66A
15.00A
14.16A
1% p-p
21.33A
12.00A
11.33A
1% p-p
17.77A
10.00A
9.44A
1% p-p
13.33A
7.50A
7.08A
1% p-p
11.42A
6.42A
6.07A
1% p-p
8.88A
5.00A
4.72A
1% p-p
6.66A
3.75A
3.54A
1% p-p
5.92A
3.33A
3.14A
1% p-p
Input & Output Connector CN2:
Howder Terminal Block No. HB-95-7P or
Mating Molex Part No. 09-91-1600 (16 pin)
Efficiency
Output Pin Assignment:
75%
80%
83%
83%
83%
83%
83%
83%
83%
83%
Howder
Molex
Pins 1 ~ 2: V+
Pins 1 ~ 5: V+
Pins 3 ~ 4: V-
Pins 6 ~ 10: V-
Pin 5: Grnd
Pin 12: Grnd
Pin 6: Neutral
Pin 14: Neutral
Pin 7: Line
Pin 16: Line
Logic Signal Connector CN1:
Mating JST XHP or equivalent (CHYAO
SHIUNN JS-21001-3) Mating Pins: JST
SXH-002T-P0.6 for AWG 30 to 26.
certification. Models are factory set to the “Preset” voltage. This may be adjusted within
Notes:
the range without affecting the agency certification. Contact the factory for details.
1. Output regulation includes line & load.
6. Output current is given for the factory preset voltage. With the exception of the “05”
2. Ripple & noise is measured from 10 Hz to 20 MHz. Measurement
output model, the maximum continuous output power level is 320W (with 28.5 CFM),
connection to the unit is made with a 0.1 µF ceramic capacitor & a 22
180W (U-Chassis convection cooled) or 170W (“C” units convection cooled. For more
µF electrolytic capacitor connected in parallel.
information, contact the factory.
3. Transient recovery is measured to within a 1% error band for a load
7. Units will provide peak power of 700W for 500 µS. For units capable of longer durations,
step change of 50% to 100%.
contact the factory.
4. Isolation specifications are production HI-Pot tested for 3 seconds.
5. The full output range (see table above) is covered in the safety agency 8. A 1% minimum load is required to maintain regulation and ripple specifications.
Fan driver connector (FAN2):
12 VDC / 400 mA is available to drive an
external fan. Mating connector is a JST
XHP-2 or Molex P/N 48-151-0210 ( 2 pins
0.98 pitch). Mating Pins: JST SXH-001TP0.62T or Molex 48150 .
Mechanical Dimensions: U-Chassis (U Suffix)
U-Chassis Cover (C Suffix)
Enclosure With End Fan (E Suffix)
Enclosure With Top Fan (F Suffix)
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]