PRELIMINARY TECHNICAL DATA SHEET 6 Lake Street, Lawrence, MA 01841 1-800-446-1158 / (978) 620-2600 / Fax: (978) 689-0803 Website: http://www.microsemi.com Gort Road Business Park, Ennis, Co. Clare, Ireland Tel: +353 (0) 65 6840044 Fax: +353 (0) 65 6822298 SILICON CARBIDE SCHOTTKY POWER RECTIFIER DEVICES MSiCSN10120 MSiCSS10120 MSiCST10120 10A / 1200V Silicon Carbide Schottky Rectifier ABSOLUTE MAXIMUM RATINGS (TC = +25°C unless otherwise noted) Parameters / Test Conditions Symbol Value Unit Peak Repetitive Reverse Voltage VRWM 1200 V Surge Peak Reverse Voltage VRSM 1200 V DC Blocking Voltage VDC 1200 V Io 10 Apk Peak Surge Forward Current @ tp = 8.3ms, half sinewave, Io = 0; VRM = 0 IFSM 50 Apk Thermal Resistance, Junction to Case Rθjc °C/W Thermal Resistance, Junction to Ambient Rθja °C/W Average Forward Current, 25°C Operating Junction Temperature Tj -65°C to +225 °C Storage Temperature Tstg -65°C to +225 °C MSiCST10120 TO-39 ELECTRICAL CHARACTERISTICS (TA = +25°C, unless otherwise noted) Parameters / Test Conditions Symbol Min. Max. Unit Forward Voltage* IF = 1A, Tj = 25°C IF = 2.5A, Tj = 25°C IF = 5.0A, Tj = 25°C IF = 10.0A, Tj = 25°C VF Reverse Current VR = 1200V, Tj = 25°C VR = 1200V, Tj = 175°C IR 100 200 µA Junction Capacitance VR = 0V f = 1MHz Cj 1200 pF 1.0 1.2 1.4 1.8 V MSiCSN10120 TO-257 * Pulse test: Pulse width 300 µsec, Duty cycle 2% Note: 1. Derate linearly @ tbd T4-LDS-0110 Rev. 1 (091991) MSiCSS10120 U-4 (SURFACE MOUNT: SMD.22) Page 1 of 4 PRELIMINARY TECHNICAL DATA SHEET 6 Lake Street, Lawrence, MA 01841 1-800-446-1158 / (978) 620-2600 / Fax: (978) 689-0803 Website: http://www.microsemi.com Gort Road Business Park, Ennis, Co. Clare, Ireland Tel: +353 (0) 65 6840044 Fax: +353 (0) 65 6822298 PACKAGE DIMENSIONS Dimensions Ltr CD CH HD LC LD LL LU L1 L2 P Q r TL TW α Term 1 Term 2 Term 3 Inches Min Max .305 .335 .160 .180 .335 .370 .200 TP .016 .021 .500 .750 .016 .019 .050 .250 .100 .040 .010 .029 .045 .028 .034 45° TP Anode Open (no connection) Cathode (case) Millimeters Min Max 7.75 8.51 4.07 4.57 8.51 9.40 5.08 TP 0.41 0.53 12.7 19.05 0.41 0.48 1.27 6.35 2.54 1.02 0.254 0.74 1.14 0.72 0.86 45° TP Notes 7 8, 9 8, 9 8, 9 8, 9 8, 9 6 5 10 7 NOTES: 1. Dimensions are in inches. 2. Millimeters are given for general information only. 3. Beyond radius (r) maximum, TW shall be held for a minimum length of .011 inch (0.279 mm). 4. Dimension TL measured from maximum HD. 5. Outline in this zone is not controlled. 6. Dimension CD shall not vary more than .010 inch (0.25 mm) in zone P. This zone is controlled for automatic handling. 7. Leads at gauge plane .054 +.001, -.000 inch (1.37 +0.03, -0.00 mm) below seating plane shall be within .007 inch (0.18 mm) radius of true position (TP) at maximum material condition (MMC) relative to tab at MMC. The device may be measured by direct methods. 8. LU applies between L1 and L2. LD applies between L2 and LL minimum. Diameter is uncontrolled in L1 and beyond LL minimum. 9. All three leads. 10. Radius (r) applies to both inside corners of tab. 11. Cathode is electrically connected to the case. 12. In accordance with ASME Y14.5M, diameters are equivalent to Φx symbology. FIGURE 1- Physical dimensions (TO-205AF - formerly low profile TO-39). T4-LDS-0110 Rev. 1 (091991) Page 2 of 4 PRELIMINARY TECHNICAL DATA SHEET 6 Lake Street, Lawrence, MA 01841 1-800-446-1158 / (978) 620-2600 / Fax: (978) 689-0803 Website: http://www.microsemi.com NOTES: 1. Dimensions are in inches. 2. Millimeters are given for general information only. 3. In accordance with ASME Y14.5M, diameters are equivalent to Φx symbology. Gort Road Business Park, Ennis, Co. Clare, Ireland Tel: +353 (0) 65 6840044 Fax: +353 (0) 65 6822298 Dimensions Symbol BL BW CH LH LL1 LL2 LS1 LS2 LW1 LW2 Q1 Q2 TERM 1 TERM 2 TERM 3 Inches Min 0.215 0.145 0.049 0.085 0.045 0.070 0.035 0.135 0.047 0.030 0.020 Cathode Anode 1 Anode 2 Max 0.225 0.155 0.075 0.020 0.125 0.075 0.095 0.048 0.145 0.057 0.070 0.035 Millimeters Min Max 5.46 5.72 3.68 3.94 1.24 1.91 0.508 2.16 3.17 1.14 1.90 1.78 2.41 0.889 1.21 3.43 3.68 1.19 1.45 0.762 1.78 0.508 0.88 FIGURE 2 - Physical dimensions and configuration (U4). T4-LDS-0110 Rev. 1 (091991) Page 3 of 4 PRELIMINARY TECHNICAL DATA SHEET 6 Lake Street, Lawrence, MA 01841 1-800-446-1158 / (978) 620-2600 / Fax: (978) 689-0803 Website: http://www.microsemi.com NOTES: 1. Dimensions are in inches. 2. Inch equivalents are given for general information only. 3. glass meniscus included in dimension TL and BL. Gort Road Business Park, Ennis, Co. Clare, Ireland Tel: +353 (0) 65 6840044 Fax: +353 (0) 65 6822298 Ltr BL CH LD LL LO LS MHD MHO TL TT TW TERM 1 TERM 2 TERM 3 Dimensions Millimeters Inches Min Max Min Max 10.41 10.92 .410 .430 4.83 5.08 .190 .200 0.64 0.89 .025 .035 12.82 15.11 .505 .595 3.05 BSC .120 BSC 2.54 BSC .100 BSC 3.56 3.81 .140 .150 13.39 13.64 .527 .537 16.38 16.89 .6450 .665 0.89 1.14 .035 .045 10.41 10.67 .410 .420 SEE SCHEMATIC SEE SCHEMATIC SEE SCHEMATIC FIGURE 3 - Physical dimensions and configuration (TO-257AA). T4-LDS-0110 Rev. 1 (091991) Page 4 of 4