Portable E Series Multifunction DAQ
12 or 16-Bit, up to 1.25 MS/s, 16 Analog Inputs
E Series – Portable
• 16 analog inputs at up to 1.25 MS/s,
12 or 16-bit resolution
• Up to 2 analog outputs at up to
1 MS/s, 12 or 16-bit resolution
• 8 digital I/O lines (TTL/CMOS); two
24-bit counter/timers
• Analog and digital triggering
• 4 analog input signal ranges
• NI-DAQ Measurement
Services simplifies configuration
and measurements
Operating Systems
• Windows 2000/NT/XP
Recommended Software
• LabVIEW
• LabWindows/CVI
• Measurement Studio
• VI Logger
Other Compatible Software
• Visual Basic, C/C++, and C#
Measurement Services
Software (included)
• NI-DAQ 7
Products
DAQCard-6036E
DAQCard-6062E
DAQCard-6024E
DAQPad-6052E
DAQPad-6070E
DAQPad-6020E
1For
Bus
PCMCIA
PCMCIA
PCMCIA
IEEE 1394
IEEE 1394
USB
Analog
Inputs
16 SE/8 DI
16 SE/8 DI
16 SE/8 DI
16 SE/8 DI
16 SE/8 DI
16 SE/8 DI
Input
Max
Resolution Sampling Rate
16 bits
200 kS/s
12 bits
500 kS/s
12 bits
200 kS/s
16 bits
333 kS/s
12 bits
1.25 MS/s
12 bits
100 kS/s
Input
Range
±0.05 to ±10 V
±0.05 to ±10 V
±0.05 to ±10 V
±0.05 to ±10 V
±0.05 to ±10 V
±0.05 to ±10 V
Analog
Outputs
2
2
2
2
2
2
Output
Resolution
16 bits
12 bits
12 bits
16 bits
12 bits
12 bits
Output
Rate
1 kS/s
850 kS/s
1 kS/s
333 kS/s
1 MS/s
100 kS/s
Output
Range
±10 V
±10 V
±10 V
±10 V
±10 V
±10 V
Digital
I/O
8
8
8
8
8
8
Counter/
Timers
2
2
2
2
2
2
Triggers
Digital
Analog, digital
Digital
Analog, digital
Analog, digital
Digital
Measurment
Services Software1
NI-DAQmx
NI-DAQmx
NI-DAQmx
Traditional NI-DAQ
Traditional NI-DAQ
Traditional NI-DAQ
up-to-date information on NI-DAQ, visit ni.com/support/daq/versions.htm
Table 1. NI Portable E Series Model Guide
Overview and Applications
Highly Accurate Hardware Design
National Instruments portable E Series DAQ products deliver the
same functionality available in PCI and PXI E Series DAQ devices –
in a portable format. The DAQPad devices are hot swappable and
available in up to three different configurations. The 15 cm enclosure
is ideal for desktop or portable applications and features a 68-pin
shielded connector. The 30 cm enclosure with mass termination
offers a low-profile package that fits under your laptop computer.
It features a 68-pin shielded connector to connect signals from our
SCC modular signal conditioning products or from our CA-1000
custom connectivity enclosure. The 30 cm enclosure with BNC
connectivity is ideal for applications where portability and quick
connectivity are needed, such as in-vehicle automotive or aircraft
testing and portable data logging.
NI DAQCards are Type II, PC Card compliant and provide
performance equivalent to their PCI or PXI counterparts. However, due
to their compact design, they can be used in applications where space
constraints are an important concern, such as field service and research.
NI portable E Series DAQ devices provide the functionality of
E Series data acquisition devices in a portable format:
Temperature Drift Protection Circuitry – Designed with components
that minimize the effect of temperature changes on measurements to
less than 0.0010% of reading per °C.
Resolution Improvement Technologies – Carefully designed noise
floor maximizes the resolution.
Onboard Self-Calibration – Precise voltage reference included for
calibration and measurement accuracy. Self-calibration is completely
software controlled, with no potentiometers to adjust.
NI DAQ-STC – Timing and control ASIC designed to provide more
flexibility, lower power consumption, and a higher immunity to noise
and jitter than off-the-shelf counter/timer chips.
NI MITE – ASIC designed to optimize data transfer for multiple
simultaneous operations using bus mastering with DMA channels,
interrupts, or programmed I/O.
Portable E Series Multifunction DAQ
12 or 16-Bit, up to 1.25 MS/s, 16 Analog Inputs
Models
Measurement Sensitivity* (mV)
Nominal Range (V)
Positive FS
Negative FS
10
-10
5
-5
2.5
-2.5
1
-1
0.5
-0.5
0.25
-0.25
0.1
-0.1
0.05
-0.05
10
0
5
0
2
0
1
0
0.5
0
0.2
0
0.1
0
NI 6052E
0.0025
NI 6070E
0.009
4.747
0.876
1.190
0.479
0.243
0.137
0.064
0.035
1.232
2.119
0.850
0.428
0.242
0.111
0.059
14.369
5.193
3.605
1.452
0.735
0.379
0.163
0.091
6.765
5.391
2.167
1.092
0.558
0.235
0.127
DAQCard-6062E
0.010
DAQPad-6020E
0.006
Absolute Accuracy (mV)
17.945
14.826
6.983
4.671
4.502
3.719
1.813
1.498
0.917
0.757
0.474
0.387
0.203
0.165
0.113
0.091
8.55
5.721
6.288
5.619
2.528
2.258
1.274
1.137
0.653
0.577
0.274
0.241
0.149
0.129
DAQCard-6036E,
0.004
DAQCard-6024E
0.009
8.653
2.357
–
–
0.454
–
–
0.067
–
–
–
–
–
–
–
19.012
6.517
–
–
0.0972
–
–
0.119
–
–
–
–
–
–
–
Note: Accuracies are valid for measurements following an internal Calibration. Measurement accuracies are listed for operational temperatures within ±1 °C of internal calibration temperature and ±10 °C of external or
factory-calibration temperature. One-year calibration interval recommended. The Absolute Accuracy at Full Scale calculations were performed for a maximum range input voltage (for example, 10 V for the ±10 V range) after one
year, assuming 100 pt averaging of data.*Smallest detectable voltage change in the input signal at the smallest input range.
Table 2. NI Portable E Series Analog Input Absolute Accuracy Specifications
Models
Nominal Range (V)
Positive FS
Negative FS
10
-10
10
0
NI 6052E
NI 6070E
1.405
1.176
8.127
5.685
DAQCard-6062E
DAQPad-6020E
Absolute Accuracy (mV)
10.568
8.133
–
5.691
DAQCard-6036E,
DAQCard-6024E
2.547
–
10.568
–
Table 3. NI Portable E Series Analog Output Absolute Accuracy Specifications
NI PGIA – Measurement and instrument class amplifier that
guarantees settling times at all gains. Typical commercial off-theshelf amplifier components do not meet the settling time
requirements for high-gain measurement applications.
Automatic Code Generation – The DAQ Assistant is an interactive
guide that steps you through configuring, testing, and programming
measurement tasks and generates the necessary code automatically
for LabVIEW, LabWindows/CVI, or Measurement Studio.
PFI Lines – Eight programmable function input (PFI) lines that can
be used for software-controlled routing of intraboard digital and
timing signals.
Cleaner Code Development – Basic and advanced software functions
have been combined into one easy-to-use yet powerful set to help
you build cleaner code and move from basic to advanced
applications without replacing functions.
RSE Mode – In addition to differential and nonreferenced singleended modes, NI portable E Series devices offer referenced
single-ended (RSE) mode for use with floating signal sources in
applications with channel counts higher than eight.
Onboard Temperature Sensor – Included for monitoring the
operating temperature of the device to ensure that it is operating
within the specified range.
Analog and Digital Triggering – Some portable E Series devices
provide the ability to set a trigger based on the level of an analog signal,
in addition to the ability to trigger off an edge of a digital signal.
High-Performance Driver Engine – Software-timed single point
input (typically used in control loops) with NI-DAQ achieves rates of
up to 50 kHz. NI-DAQ also delivers maximum system throughput
I/O with a multithreaded driver.
Test Panels – With NI-DAQ, you can test all of your device
functionality before you begin development.
Scaled Channels – Easily scale your voltage data into the proper
engineering units using the NI-DAQ measurement-ready virtual
channels by choosing from a list of common sensors and signals or
creating your own custom scale.
High-Performance, Easy-to-Use Driver Software
Measurement Services Software includes NI-DAQ, the robust driver
software that makes it easy to access the functionality of your data
acquisition hardware, whether you are a beginning or advanced user.
Helpful features include:
2
National Instruments • Tel: (800) 433-3488 • [email protected] • ni.com
LabVIEW Integration – All NI-DAQ functions use the waveform data
type, which carries acquired data and timing information directly
into more than 400 LabVIEW built-in analysis routines for display of
results in engineering units on a graph.
Portable E Series Multifunction DAQ
12 or 16-Bit, up to 1.25 MS/s, 16 Analog Inputs
Worldwide Support and Services
Recommended Accessories
NI provides you with a wealth of resources to help you get your
application up and running more quickly, including:
Signal conditioning is required for sensor measurements or voltage
inputs greater than 10 V. National Instruments SCXI is a versatile,
high-performance signal conditioning platform, intended for highchannel-count applications. NI SCC products provide portable,
flexible signal conditioning options on a per-channel basis. Both
signal conditioning platforms are designed to increase the
performance and reliability of your DAQ System, and are up to 10X
more accurate than terminal blocks (please visit ni.com/sigcon for
more details). Refer to the table below for more information:
Technical Support – Purchase of NI hardware or software gives you
access to application engineers all over the world as well as Web
resources with more than 3,000 measurement examples and more
than 9,000 KnowledgeBase entries. – ni.com/support
Calibration – Includes NIST-traceable basic calibration certificates,
services for ANSI/NCSL-Z540 and periodic calibration –
ni.com/calibration
Extended Warranty – Meet project life-cycle requirements and
maintain optimal performance in a cost-effective way – ni.com/services
For more information on NI services and support,
please visit ni.com/services
Sensor/Signals (>10 V)
System Description
High performance
Low-Cost, portable
DAQ Device
DAQCard-60xxE, DAQPad-60xxE
DAQCard-60xxE, DAQPad-60xxE
Signals (<10 V)1
System Description
Shielded
Shielded
Low-Cost
Low-Cost
DAQ Device
DAQPad-60xxE
DAQCard-60xxE
DAQPad-60xxE
DAQCard-60xxE
Signal Conditioning
SCXI
SCC
Terminal Block
Cable
SCB-68
SH6868-EP
SCB-68
SHC6868-EP
CB-68LP
R6868
CB-68LP
RC6868
Blocks do not provide signal conditioning (ie. filtering, amplification, isolation, etc.), which may be
necessary to increase the accuracy of your measurements.
1 Terminal
Visit ni.com/oem for information on our quantity discounts.
Table 4. Recommended Accessories
For information on device support in NI-DAQ 7,
visit ni.com/dataacquisition
Ordering Information
NI DAQCard-6036E ....................................................................778561-01
NI DAQCard-6062E ....................................................................777976-01
NI DAQCard-6024E ....................................................................778269-01
NI DAQPad-6052E1 for FireWire (IEEE 1394) with
Mass termination, AC Adapter 2, and 4 m FireWire cable
US 120 VAC ........................................................................778535-01
Universal Euro 240 VAC ....................................................778535-04
United Kingdom 240 VAC.................................................778535-06
BNC termination, AC Adapter2, and 4 m FireWire cable
US 120 VAC ........................................................................778536-01
Universal Euro 240 VAC ....................................................778536-04
United Kingdom 240 VAC.................................................778536-06
NI DAQPad-6070E for FireWire1 (IEEE 1394) with
Mass termination, AC Adapter 2, and 4 m FireWire cable
US 120 VAC ........................................................................777867-01
Universal Euro 240 VAC ....................................................777867-04
United Kingdom 240 VAC.................................................777867-06
BNC termination, AC Adapter 2, and 4 m FireWire cable
US 120 VAC ........................................................................777803-01
Universal Euro 240 VAC ....................................................777803-04
United Kingdom 240 VAC.................................................777803-06
NI DAQPad-6020E for USB1 in
15 cm enclosure with AC Adapter 2, and 1 m USB cable
US 120 VAC ........................................................................777474-01
Universal Euro 240 VAC ....................................................777474-04
United Kingdom 240 VAC.................................................777474-06
Japan 120 VAC....................................................................777474-07
30 cm enclosure with mass termination,
AC Adapter 2, and 1 m USB cable
US 120 VAC ....................................................................777704-01
Universal Euro 240 VAC ................................................777704-04
United Kingdom 240 VAC ............................................777704-06
Japan 120 VAC................................................................777704-07
30 cm enclosure with BNC termination AC Adapter 2,
and 1 m USB cable
US 120 VAC ....................................................................777703-01
Universal Euro 240 VAC ................................................777703-04
United Kingdom 240 VAC ............................................777703-06
Japan 120 VAC................................................................777703-07
Includes NI-DAQ software
1Windows 2000/XP only for DAQPads
2The AC Adapter is universal. The difference between these kits is the power cable.
DAQPad Accessories
BP-1 rechargeable battery pack
120 VAC charger........................................................776896-01
230 VAC charger........................................................776896-31
Rack-mount kit ............................................................777665-01
Stacking kit ....................................................................777666-01
PCI-to-IEEE 1394 adapter ............................................Please call
CardBus-to-IEEE 1394 adapter ....................................Please call
BUY ONLINE!
Visit ni.com/dataacquisition
National Instruments • Tel: (800) 433-3488 • [email protected] • ni.com
3
NI Services and Support
NI has the services and support to meet your
needs around the globe and through the
application life cycle – from planning
and development through deployment
and ongoing maintenance. We offer
services and service levels to meet
customer requirements in research,
design, validation, and manufacturing.
Visit ni.com/services.
Local Sales and Technical Support
SERVICE
NEEDS
In offices worldwide, our staff is local to the country, giving you
access to engineers who speak your language. NI delivers industryleading technical support through online knowledge bases, our
applications engineers, and access to 14,000 measurement and
automation professionals within NI Developer Exchange forums.
Find immediate answers to your questions at ni.com/support.
We also offer service programs that provide automatic upgrades to
your application development environment and higher levels of
technical support. Visit ni.com/ssp.
Training and Certification
NI training is the fastest, most certain route to productivity with our
products. NI training can shorten your learning curve, save
development time, and reduce maintenance costs over the
application life cycle. We schedule instructor-led courses in cities
worldwide, or we can hold a course at your facility. We also offer a
professional certification program that identifies individuals who
have high levels of skill and knowledge on using NI products.
Visit ni.com/training.
Hardware Services
NI Factory Installation Services
NI Factory Installation Services (FIS) is the fastest and easiest way to
use your PXI or PXI/SCXI combination systems right out of the box.
Trained NI technicians install the software and hardware and
configure the system to your specifications. NI extends the standard
warranty by one year on hardware components (controllers, chassis,
modules) purchased with FIS. To use FIS, simply configure your
system online with ni.com/pxiadvisor.
Professional Services
Our Professional Services Team is comprised of NI applications
engineers, NI Consulting Services, and a worldwide NI Alliance
Partner Program of more than 600 independent consultants and
integrators. Services range
from start-up assistance to
turnkey system integration.
Visit ni.com/alliance.
Calibration Services
NI recognizes the need to maintain properly calibrated devices for
high-accuracy measurements. We provide manual calibration
procedures, services to recalibrate your products, and automated
calibration software specifically designed for use by metrology
laboratories. Visit ni.com/calibration.
Repair and Extended Warranty
OEM Support
We offer design-in consulting and product integration assistance
if you want to use our products for OEM applications. For
information about special pricing and services for OEM customers,
visit ni.com/oem.
NI provides complete repair services for our products. Express repair
and advance replacement services are also available. We offer
extended warranties to help you meet project life-cycle requirements.
Visit ni.com/services.
ni.com • (800) 433-3488
National Instruments • Tel: (512) 683-0100 • [email protected]
© 2005 National Instruments Corporation. All rights reserved. CVI, LabVIEW, Measurement Studio, National Instruments Alliance Partner, ni.com, NI-DAQ
and SCXI are trademarks of National Instruments. Other product and company names listed are trademarks or trade names of their respective companies.