OPLINK TRPA12MSM

Multi-rate OC-12/STM-4 SFP
Transceivers with Digital Diagnostics
TRPA12M SM
Product Description
The TRPA12M SFP series of multi-rate fiber optic transceivers with integrated digital diagnostics monitoring functionality provide a quick and
reliable interface for OC-12 short reach (SR), intermediate reach (IR) and
long reach (LR) applications. The diagnostic functions, alarm and warning
features as described in the Multi-Source Agreement (MSA) document,
SFF-8472 (Rev. 9.3), are provided via an I2C serial interface.
Available products under this series are compliant with SONET/SDH standards for OC-12/STM-4 applications and are capable of operating down to
155Mb/s data rate. The SR-1 and IR-1 versions are compliant with OC-12/
STM-4 and OC-3/STM-1 interface standards. All modules satisfy Class I
Laser Safety requirements in accordance with the U.S. and international
standards as described in the FDA/CDRH and IEC-60825 documents, respectively.
The TRPA12M multi-rate transceivers connect to standard 20-pad SFP
connectors for hot plug capability. This allows the system designer to
make configuration changes or maintenance by simply plugging in different types of transceivers without shutting down the power supply of
the host system.
The transceivers have colored bail-type latches, which offer an easy and
convenient way to release the modules. The latch is compliant with the
SFP MSA.
Features
 Compliant with SONET/SDH OC-12/STM-4
(622Mb/s)
 Compatible with SONET/SDH OC-3/STM-1
(155Mb/s)
 Compatible with SFP MSA
 SONET/SDH Reaches (SR-1, IR-1, LR-1 & LR-2)
 Digital Diagnostics through Serial Interface
The transmitter design incorporates a highly reliable 1310nm or 1550nm
InGaAsP laser and an integrated driver circuit. The receiver features a transimpedance amplifier IC optimized for high sensitivity and wide dynamic
range. The transmitter and receiver DATA interfaces are AC-coupled internally. LVTTL Transmitter Disable control input and Loss of Signal output
interfaces are also provided.
 Internal Calibration for Digital Diagnostics
The transceivers operate from a single +3.3V power supply over two operating case temperature ranges of -5°C to +70°C and -40°C to +85°C.
 Hot-pluggable
 Eye Safe (Class I Laser Safety)
 Duplex LC Optical Interface
 -40°C to +85°C Operating Temperature Option
 Excellent EMI & ESD Protection
 TX Fault & Loss of Signal Outputs
 TX Disable Input
 Single +3.3V Power Supply
Absolute Maximum Ratings
Parameter
Storage Temperature
Operating Case Temperature 1
“B” option
“A” option
Symbol
Minimum
Maximum
Units
Tst
- 40
+ 85
°C
-5
+ 70
- 40
+ 85
Top
°C
Supply Voltage
Vcc
0
+ 5.0
V
Input Voltage
Vin
0
+ 5.0
V
1
Measured on top side of SFP module at the front center vent hole of the cage.
An Oplink Company
RevC-P.2009.04.01
TRPA12M Single Mode Multi-rate
Transmitter Performance Characteristics (Over Operating Case Temperature, VCC = 3.13 to 3.47V)
Parameter
Operating Data Rate
Average Optical Output Power
(coupled into single mode fiber),
50% duty cycle
SR-1 & IR-1
LR-1 & LR-2
Symbol
Minimum
Typical
Maximum
Units
B
125
-
622
Mb/s
- 15.0
- 11.0
- 8.0
- 3.0
- 1.0
+ 2.0
-
-
- 45.0
8.2
-
-
10
-
-
1261
1310
1360
1274
1310
1356
PO
POFF
Transmitter OFF Output Power
SR-1 & IR-1
Extinction Ratio
LR-1 & LR-2
Phi /Plo
SR-1
Center Wavelength
IR-1
1
λC
1293
1310
1334
1280
1310
1335
LR-2
1480
1550
1580
-
-
4.0
-
-
2.5 or 4.0
ΔλRMS
IR-1
dBm
dB
LR-1
SR-1
Spectral Width (RMS) 1
dBm
nm
nm
Spectral Width (-20dB)
LR-1 & LR-2
Δλ20
-
-
1.0
nm
Side Mode Suppression Ratio
LR-1 & LR-2
SMSR
30
-
-
dB
Optical Output Eye
1
Compliant with Telcordia GR-253-CORE and ITU-T Recommendation G.957
For IR version, the center wavelength is either 1274nm ≤ λc ≤ 1356nm for ΔλRMS ≤ 2.5nm
or 1293nm ≤ λc ≤ 1334nm for ΔλRMS ≤ 4.0nm
Receiver Performance Characteristics (Over Operating Case Temperature, VCC = 3.13 to 3.47V)
Parameter
Operating Data Rate
Receiver Sensitivity (10 BER)
-10
1
Minimum
Typical
Maximum
Units
B
125
-
622
Mb/s
Pmin
- 28.0
- 31.0
-
dBm
dBm
Pmax
- 7.0
- 3.0
-
Increasing Light Input
Plos+
-
-
- 28.0
Decreasing Light Input
Plos-
- 45.0
-
-
Maximum Input Optical Power (10 BER)
-10
LOS Thresholds 1
Symbol
1
dBm
Increasing Light Input
t_loss_off
-
-
100
Decreasing Light Input
t_loss_on
2.3
-
100
LOS Hysteresis
-
0.5
1.5
-
dB
Wavelength of Operation
λ
1100
-
1600
nm
Receiver Reflectance (LR-2)
-
-
-
- 27.0
dB
LOS Timing Delay
1
µs
Specified in average optical input power and measured at 155Mb/s & 622Mb/s and 1310nm wavelength (1550nm for LR-2) with 2 -1 PRBS, and at
125Mb/s with 27-1 PRBS.
23
Laser Safety: All transceivers are Class I Laser products per
FDA/CDRH and IEC-60825 standards. They must be operated under specified operating conditions.
Oplink Communications, Inc.
DATE OF MANUFACTURE:
This product complies with
21 CFR 1040.10 and 1040.11
Meets Class I Laser Safety Requirements
Oplink Communications, Inc.
2
RevC-P.2009.04.01
TRPA12M Single Mode Multi-rate
Transmitter Electrical Interface (Over Operating Case Temperature, VCC = 3.13 to 3.47V)
Parameter
Symbol
Minimum
Input Voltage Swing (TD+ & TD-) 1
VPP-DIF
0.25
Input HIGH Voltage (TX Disable) 2
VIH
2.0
Input LOW Voltage (TX Disable)
2
VIL
0
Output HIGH Voltage (TX Fault)
3
VOH
VOL
Output LOW Voltage (TX Fault) 3
Typical
Maximum
Units
-
2.4
V
-
VCC
V
-
0.8
V
2.0
-
VCC + 0.3
V
0
-
0.8
V
Differential peak-to-peak voltage.
There is an internal 4.7 to 10kΩ pull-up resistor to VccT.
3
Open collector compatible, 4.7 to 10kΩ pull-up resistor to Vcc (Host Supply Voltage).
1
2
Receiver Electrical Interface (Over Operating Case Temperature, VCC = 3.13 to 3.47V)
Parameter
Symbol
Minimum
Typical
Maximum
Units
VPP-DIF
0.6
-
2.0
V
VOH
2.0
-
VCC + 0.3
V
VOL
0
-
0.5
V
Output Voltage Swing (RD+ & RD-) 1
Output HIGH Voltage (LOS)
2
Output LOW Voltage (LOS) 2
1
2
Differential peak-to-peak voltage across external 100Ω load.
Open collector compatible, 4.7 to 10kΩ pull-up resistor to Vcc (Host Supply Voltage).
Electrical Power Supply Characteristics (Over Operating Case Temperature, VCC = 3.13 to 3.47V)
Parameter
Symbol
Minimum
Typical
Maximum
Units
Supply Voltage
VCC
3.13
3.3
3.47
V
Supply Current
ICC
-
210
275
mA
Module Definition
MOD_DEF(0)
pin 6
MOD_DEF(1)
pin 5
MOD_DEF(2)
pin 4
Interpretation by Host
TTL LOW
SCL
SDA
Serial module definition protocol
Electrical Pad Layout
20
TX GND
1
TX GND
19
TD- (TX DATA IN-)
2
TX Fault
18
TD+ (TX DATA IN+)
3
TX Disable
17
TX GND
4
MOD_DEF(2)
16
VccTX
5
MOD_DEF(1)
15
VccRX
6
MOD_DEF(0)
14
RX GND
7
NO CONNECTION
13
RD+ (RX DATA OUT+)
8
LOS
12
RD- (RX DATA OUT-)
9
RX GND
11
RX GND
10
RX GND
Top of Board
Oplink Communications, Inc.
Host Board Connector Pad Layout
1
2
3
Toward
Bezel
4
5
6
7
8
9
Bottom of Board
(as viewed thru top of board)
10
3
20
19
18
17
16
15
Toward
ASIC
14
13
12
11
RevC-P.2009.04.01
TRPA12M Single Mode Multi-rate
Example of SFP host board schematic
Vcc
3.3V
1µH coil or ferrite bead
(<0.2Ω series resistance)
Vcc
3.3V
+
10
0.1
0.1
+
10
0.1
R
16
2
15
TRPA12M
3
TX Disable
100
50Ω line
TX DATA IN+
TX DATA IN-
50Ω line
R
MOD_DEF(2)
MOD_DEF(1)
6
50Ω line
13
19
12
R
TX Fault
LOS
8
4
5
18
R
50Ω line
MOD_DEF(0)
(100Ω to ground internally)
RX DATA OUT+
to 50Ω load
RX DATA OUTto 50Ω load
1, 9, 10, 11, 14, 17, 20
R: 4.7 to 10kΩ
Application Notes
Electrical Interface: All signal interfaces are compliant with
the SFP MSA specification. The high speed DATA interface
is differential AC-coupled internally with 0.1μF and can be
directly connected to a 3.3V SERDES IC. All low speed control
and sense output signals are open collector TTL compatible
and should be pulled up with a 4.7 - 10kΩ resistor on the host
board.
up, MOD_DEF(1:2) appear as NC (no connection), and
MOD_DEF(0) is TTL LOW. When the host system detects this
condition, it activates the serial protocol (standard two-wire
I2C serial interface) and generates the serial clock signal (SCL).
The positive edge clocks data into the EEPROM segments of
the SFP that are not write protected and the negative edge
clocks data from the SFP.
Loss of Signal (LOS): The Loss of Signal circuit monitors the
level of the incoming optical signal and generates a logic HIGH
when an insufficient photocurrent is produced.
The serial data signal (SDA) is for serial data transfer. The
host uses SDA in conjunction with SCL to mark the start and
end of serial protocol activation. The supported monitoring
functions are temperature, voltage, bias current, transmitter
power, average receiver signal, all alarms and warnings, and
software monitoring of TX Fault/LOS. The device is internally
calibrated.
TX Fault: The output indicates LOW when the transmitter
is operating normally, and HIGH with a laser fault including
laser end-of-life. TX Fault is an open collector/drain output
and should be pulled up with a 4.7 - 10kΩ resistor on the host
board. TX Fault is non-latching (automatically deasserts when
fault goes away).
The data transfer protocol and the details of the mandatory
and vendor specific data structures are defined in the SFP MSA
and SFF-8472, Rev. 9.3.
TX Disable: When the TX Disable pin is at logic HIGH, the
transmitter optical output is disabled (less than -45dBm).
Power Supply and Grounding: The power supply line should
be well-filtered. All 0.1μF power supply bypass capacitors
should be as close to the transceiver module as possible.
Serial Identification and Monitoring: The module definition
of SFP is indicated by the three module definition pins,
MOD_DEF(0), MOD_DEF(1) and MOD_DEF(2). Upon power
Oplink Communications, Inc.
4
RevC-P.2009.04.01
TRPA12M Single Mode Multi-rate
Package Outline
56.7
2.23 REF
0
1.27 -0.13
.050 +.000
-.005
13.67
13.54
.54
.53
0
0.98 -0.13
+.000
.038 -.005
46335 Landing Pkwy Fremont, CA 94538-6407 Tel: (510) 933-7200 Fax: (510) 933-7300 Email: [email protected] • www.oplink.om
6.25±0.05
.246±.002
1
.04
FRONT EDGE OF
TRANSCEIVER CAGE
47.3
1.861
8.9
.350
13.9±0.2
.546±.008
8.51
.335
1.8
.07
41.8±0.15
1.646±.006
45±0.20
1.771±.008
Dimensions in inches [mm]
Default tolerances:
.xxx = ± .005”, .xx = ± .01”
Ordering Information
1
Model Name
Operation Temperature
Latch
Color
Nominal
Wavelength
SONET/SDH
Standad
Reach 1
TRPA12S1ABAM
- 5°C to +70°C
Gray
1310nm
SR-1/I-4
12/2km
TRPA12I1ABYM
- 5°C to +70°C
Yellow
1310nm
IR-1/S-4.1
21/15km
TRPA12L1GBRM
- 5°C to +70°C
Red
1310nm
LR-1/L-4.1
42/40km
TRPA12L2GBWM
- 5°C to +70°C
White
1550nm
LR-2/L-4.2
85/80km
TRPA12S1AAAM
40°C to +85°C
Gray
1310nm
SR-1/I-4
12/2km
TRPA12I1AAYM
40°C to +85°C
Yellow
1310nm
IR-1/S-4.1
21/15km
TRPA12L1GARM
40°C to +85°C
Red
1310nm
LR-1/L-4.1
42/40km
TRPA12L2GCWM
40°C to +85°C
White
1550nm
LR-2/L-4.2
85/80km
These are target distances to be used for classification and not for specification, per Telcordia GR-253-CORE/ITU-T Recommendation G.957.
Oplink can provide a remarkable range of customized optical solutions. For detail, please contact Oplink’s Sales and Marketing for your requirements and ordering information (510) 933-7200 or [email protected].
Oplink Communications, Inc. reserves the right to make changes in equipment design or specifications without notice. Information supplied by Oplink Communications, Inc. is believed to be accurate and reliable. However, no responsibility is assumed by Oplink Communications, Inc. for its use nor for any infringements
of third parties, which may result from its use. No license is granted by implication or otherwise under any patent right of Oplink Communications, Inc.
RevC-P.2009.04.01
© 2008, Oplink Communications, Inc.
5