FM4001 thru FM4007 SURFACE MOUNT STANDARD RECOVERY RECTIFIER VOLTAGE - 50 TO 1000 VOLTS CURRENT - 1.0 AMPERES SMA/DO-214AC .055(1.40) .062(1.60) .098(2.50) .114(2.90) .157(4.00) .181(4.60) .006(.152) .012(.305) .078(2.00) .096(2.44) .030(0.76) .060(1.52) .004(.102) .008(.203) .188(4.80) .208(5.28) Dimensions in inches and (millimeters) FEATURES MECHANICAL DATA For surface mount applications Glass passivated junction Low profile package Built-in strain relief Easy pick and place Low forward voltage drop Plastic package has Underwriters Laboratory Flammability Classification 94V-0 High temperature soldering 250oC/10 seconds at terminsls Case JEDEC DO-214AC molded plastic Terminals Solder plated, solderable per MIL-STD-202, Method 208 Polarity Color band denotes cathode end Standard Package 12mm tape (EIA STD EIA-481) Weight 0.002 ounce, 0.064gram MAXIMUM RATIXGS AND ELECTRICAL CHARACTERISTICS Ratings at 25oC ambient temperature unless otherwise specified Single phase, half wave, 60Hz, resistive or inductive load For capacitive load, derate current by 20% SYMBOL FM4001 FM4002 FM4003 FM4004 FM4005 FM4006 FM4007 UNITS Maximum Repetitive Peak Reverse Voltage VRRM Maximum RMS Voltage VRMS Maximum DC Blocking Voltage VDC Maximum Average Forward Rectified Current at TL =1000C I(AV) 1.0 Amps Peak Forward Surge Current 8.3mm Single Half wine-Wave Superimposed on Rated Load (JEDEC Method) IFSM 30 Amps Maximum Instantaneous Forward Voltage at 1.0A VF 1.1 Volts Maximum DC Reverse Current TA=250C at Rated DC Blocking Voltage TA=1250C IR 5 50 A Typical Junction Capacitance (NOTE 1) CJ 12 pF Maximum Thermal Resistance (NOTE 2) R R Operating and Storage Temperature Range TJ TSTG JL 400 600 800 35 70 140 280 420 560 700 Volts 50 100 200 400 600 800 1000 Volts -55 to +150 NOTES 1. Measured at 1.0 MHz and applied reverse voltage of 4.0 volts 2. P.C.B. mounted on 0.2x0.2 (5.0x5.0mm)copper pad areas www.paceleader.tw 200 75 30 JA 1 1000 100 50 Volts 0 C/W 0 C FM4001 thru FM4007 SURFACE MOUNT STANDARD RECOVERY RECTIFIER RATING AND CHARACTERISTICS CURVES FM4001 THRU FM4007 Fig. 2 - MAXIMUM NON-REPETITIVE PEAK FORWARD Fig. 1 - FORWARD CURRENT DERATING CURVE PEAK FORWARD SURGE CURRENT, (A) AVERAGE FORWARD CURRENT, (A) 2.0 SURGE CURRENT SINGLE PHASE HALF WAVE 60Hz RESISTIVE OR INOUCTIVE LOAD P.C.B MOUNTED ON 0.315x0.315"(8.0x8.0mm) COPPER PAD AREAS 1.0 0 75 100 125 150 175 25 50 0 LEAD TEMPERATURE, C 30 25 8.3ms Single Half Sine-Wave JEDEC Method 20 15 10 5 1 2 5 10 20 50 100 NUMBER OF CYCLES AT 60 Hz Fig. 4 - TYPICAL INSTANTANEOUS FORWARD CHARACTERISTICS INSTANTANEOUS REVERSE CURRENT MICROAMPERES 100 10 0 TJ=125C 1 0 TJ=75C 0.1 0 TJ=25C 0.01 0.001 0 20 40 60 80 100 120 140 100 50 20 10 5 2 1 0.5 0.2 0.1 0.05 0.02 0.01 0.4 0.6 0.8 1.2 1 1.4 1.6 1.8 2 INSTANTANEOUS FORWARD VOLTAGE, (V) PERCENT OF PEAK REVERSE VOLTAGE, % Fig. 5 - TRANSIENT THERMAL IMPEDANCE Fig. 6 - TYPICAL JUNCTION CAPACITANCE THERMAL IMPEDANCE ( 0C/W ) INSTANTANEOUS REVERSE CURRENT, (mA) Fig. 3 - TYPICAL REVERSE CHARACTERISTICS 100 1,000 200 100 Units Mounted on 2 20in2(5. 4mm)+0 .5mil inches (0.013mm) Thick Copper Land Areas 50 CAPACITANCE-pF 500 50 20 10 5 2 1 0.01 0.1 1 10 10 5 2 0.1 1 10 REVERSE VOLTAGE(V) HEATING TIME (SEC) www.paceleader.tw 20 1 0.01 100 0 TJ=25C f=1.0MHz Vsig=50m Vp-p 2 100