ETC GS1G

RS
GS1A THRU GS1M
SURFACE MOUNT STANDARD RECOVERY RECTIFIER
VOLTAGE - 50 TO 1000 VOLTS CURRENT - 1.0 AMPERE
FEATURES
SMA / DO-214AC
Dim Min Max
A
2.29 2.92
B
4.00 4.60
1.25 1.65
C
0.152 0.305
D
4.80 5.59
E
0.051 0.203
G
0.76 1.52
H
2.00 2.62
J
All Dimensions in mm
B
C
A
D
J
H
For surface mount applications
Glass passivated junction
Low profile package
Built-in strain relief
Easy pick and place
Low forward voltage drop
Plastic package has Underwriters Laboratory
Flammability Classification 94V-0
High temperature soldering:
250oC/10 seconds at terminals
G
E
MECHANICAL DATA
Case: JEDEC DO-214AC molded plastic
Terminals: Solder plated, solderable per
MIL-STD-202, method 208
Polarity: Color band denotes cathode end
Standard Package: 12mm tape (EIA STD EIA-481)
Weight: 0.002 ounce, 0.064 gram
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25oC ambient temperature unless otherwise specified
Single phase half wave 60 Hz, resistive or inductive load
For capacitive load, derate current by 20%
Maximum Repetitive Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
at TL = 100oC
SYMBOL GS1A GS1B GS1D GS1G GS1J GS1K GS1M UNITS
50
100 200 400 600
VRRM
800 1000
Volts
35
70
140 280 420
VRMS
560 700
Volts
50
100
200
400
600
800
1000
Volts
VDC
I(AV)
1.0
Amps
IFSM
30
Amps
VF
1.1
Volts
IR
5
50
A
CJ
12
pF
Peak Forward Surge Current
8.3ms single half sine-wave superimposed
on rated load (JEDEC Method)
Maximum Instantaneous Forward Voltage at 1.0A
Maximum DC Reverse Current
TA = 25oC
at Rated DC Blocking Voltage
TA = 125oC
Typical Junction Capacitance (NOTE 1)
Maximum Thermal Resistance (NOTE 2)
Operating and Storage Temperature Range
R
R
JA
JL
TJ, TSTG
NOTES:
1. Measured at 1.0 MHz and applied reverse voltage of 4.0 volts
2. P.C.B. mounted on 0.2 x 0.2" (5.0 x 5.0mm) copper pad areas
75
30
-55 to +150
o
C/W
o
C
RS
GS1A THRU GS1M
P.C.B. MOUNTED ON
0.2 x 0.2" (5.0 x 5.0mm)
COPPER PAD AREAS
1.0
SINGLE PHASE
HALF WAVE 60Hz
RESISTIVE OR
INDUCTIVE LOAD
0.5
0
0
25
50
75
100
125
150
175
PEAK FORWARD SURGE CURRENT
(AMPS)
AVERAGE FORWARD CURRENT
(AMPS)
30
1.5
O
LEAD TEMPERATURE ( C)
Figure 1. Typical Forward Current Derating Curve
25
8.3 MS SINGLE HALF
SINE-WAVE JEDEC METHOD
20
15
10
5
0
100
10
1
NUMBER OF CYCLES AT 60Hz
100
100
10
1
TJ = 25OC
PULSE WIDTH = 300
1% DUTY CYCLE
TJ = 25OC
f = 1.0MHz
Vsig = 50mVp-p
JUNCTION CAPACITANCE
(pF)
INSTANTANEOUS FORWARD CURRENT
(AMPS)
Figure 2. Maximum Non-Repetitive Peak Forward Surge Current
S
0.1
10
1
0.01
0.01
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
0.1
2.0
1.0
10
100
REVERSE VOLTAGE (VOLTS)
Figure 4.Typical Junction Capacitance
INSTANTANEOUS FORWARD VOLTAGE (VOLTS)
Figure 3. Typical Instantaneous Forward Characteristics
INSTANTANEOUS REVERSE CURRENT
A)
10
THERMAL IMPEDANCE
(OC / W)
1000
100
10
UNITS MOUNTED ON 0.2x0.2"
(5.0x5.0mm) x 0.5mil. INCHES
(0.013mm) THICK COPPER
LAND AREAS
TJ = 125 OC
1
TJ = 100 OC
0.1
TJ = 25 OC
0.01
1
0.01
0.1
1.0
10
HEATING TIME (SEC)
Figure 5.Transient Thermal Impedance
100
0.001
0
20
40
60
80
PERCENT OF PEAK REVERSE VOLT AGE(%)
Figure 6.Typical Reverse Characteristics
100