PHIHONG PSM500-216

WWW.PHIHONG.COM
PSM500 500W 1U RPS and Bulk n+1 Power Supply
with active PFC
Features
•
•
•
SELV Output with 1500VAC Isolation
500 Watts X 3 in 1U 19” Rack
Hot Plug N+1
•
•
•
Diagnostics
Full Protection OTP, OCP, OVP
85-265VAC with Active PFC
•
•
Network Redundant Power Source
Servers
•
TUV
•
•
Height: 41mm (1.61in)
Weight: 1.81kg (4lb.)
Applications
•
•
Power Over Ethernet
Telecommunications
Safety Approvals
•
•
cUL/UL
CE
Mechanical Characteristics
•
•
Length: 300mm (11.81in)
Width: 107mm (4.21in)
Output Specifications
Load
Model
PSM500-210
PSM500-216
Ripple (1)
DC Output
Voltage
50V (main)
12V (stand by)
56V (main)
12V (stand by)
Min.
0A
0A
0A
0A
Max.
10A
1.5A
9A
1.5A
P-P (max)
1%
1%
Regulation
Line
Load
±0.5V
±0.5V
Note: (1) Measured with by-pass capacitors 0.1uf/10uf at output connector terminal and oscilloscope set at 20Mhz.
Phihong reserves the right to make changes without further notice. Please consult Phihong USA and visit
www.phihong.com for the most up-to-date specifications.
PSM500-210, -216 Characteristics
INPUT:
AC Input Voltage Range
85 to 264VAC
AC Input Current
6A(RMS) max. for 115VAC
3A(RMS) max. for 230VAC
AC Input Line Fuse
WWW.PHIHONG.COM
EMC
FCC Class B
EN55022 conducted Class B *with external filter
(*measured with Y capacitors 0.01uf/400Vat main
output connector terminal from ± V to unit chassis)
EN55022 conducted Class B; radiated Class A
(using 3 x PSM500-210,or -216 in rack “PSA1554-605”)
Isolation Test
10A / 250V
Leakage Current
3.5mA max. @ 254VAC 60Hz
Primary to Secondary: 4242VDC
Primary to Ground: 2121VDC
Secondary to Ground: 2121VDC
Immunity EN50082-1
AC Input Frequency
47-63Hz
AC Inrush Current
30A(RMS) max. for 115VAC
60A(RMS) max. for 230VAC
ESD:
EFT:
Surge:
CS:
Voltage Dips
RS:
Harmonic:
EN61000-4-2. Level 3
EN61000-4-4. Level 2
EN61000-4-5. Level 3
EN61000-4-6. Level 3
EN61000-4-11
EN61000-4-3. Level 3
EN61000-3-2
OUTPUT:
Efficiency
FEATURE:
83% typical at max. load (115VAC)
85% typical. at max. load (230VAC)
Front Panel LED
Hold-up Time
50V Enable/Disable
10mS min. 120VAC and max. load
Non latching – remote on/off pin
Over Voltage Protection
Thermal Shutdown
OV set at 57~60V – latching.
Latching
Over Current Protection
Fan Fail
Protection against short circuit. Isc max 110%-140% full
load current. The 50V, 56V can operate in current mode
till shot circuit and can be shorted permanently without
damage.
Latching
ENVIRONMENTAL:
Isolated Diode
Temperature
Internal Oring Diode located on main (-) output section.
Operation
Non-operation
DC Good, Fault condition
Load Sharing
10% at full load
0 to +50°C
-30 to +70°C
Output Connector
Humidity
Operation
8 to 90%
Molex p/n 15060141 or equivalent
Molex p/n 15249144 or equivalent (mating)
Dimension Diagram Unit: mm (inch)