WWW.PHIHONG.COM 8 Port Gigabit Power Over Ethernet Midspan POE125 for 10/100/1000 Base-T Networks Features • IEEE 802.3af Detection, Disconnect and overload Protection • Low Cost • 10/100/1000 base T Compatible Applications • VoIP Phones • Access Point Safety Approvals • cUL/UL Mechanical Characteristics • Length: 228mm (8.9in) • Width: 198mm (7.8in) Output Specifications • • • Full Power of 125W--15.4W per Port No Power Management required Full Protection OTP, OCP, OVP Rack mount with optional kit • • Security Systems IP Cameras • CE • • Height: 44.5 mm (1.75in) Weight: 1.0Kg (2.5lbs) Model Number of Ports Cisco Legacy Support SNMP Management POE125U-8 POE125U-8C POE125U-8N 8 8 8 No Yes Yes No No Yes Phihong is not responsible for any error and change. Content is subject to change without notice. Please consult the factory and visit www.phihong.com for the most up-to-date specifications. POE125 Characteristics INPUT: AC Input Voltage Range 90 to 264VAC Input Frequency 47-63Hz Input Current: 2.2A(RMS) max. for 90VAC 1A(RMS) max. for 240VAC Leakage Current: 3.5mA max. @ 254VAC 60Hz AC Inrush Current: 15A(RMS) max. for 115VAC 20A(RMS) max. for 230VAC WWW.PHIHONG.COM Immunity EN50082-1 ESD: RS: EFT: Surge: CS: Voltage Dips Harmonic: EN61000-4-2. Level 3 EN61000-4-3. Level 2 EN61000-4-4. Level 2 EN61000-4-5. Level 3 EN61000-4-6. Level 2 EN61000-4-11 EN61000-3-2 Class A IEEE 802.3af Interoperability UNH Interoperability report available on request FEATURE: OUTPUT: Total Output Power 15.4W per port Ripple and Regulation Meets requirements of IEEE802.3af Efficiency 75% (typical) at Max. load, and 120VAC 60Hz Hold-up Time 20mS min. 120VAC and max. load Transient O/P Voltage Protection Cisco Legacy detection(Option) No extern parts required for Legacy devices: VoIP Phones: 7910,7912,7940,7960 Access Points: 350,1100,1200 Over Voltage/Current, Short Circuit Protection Outputs equipped with short circuit protection and overload protection as per 802.3af specification The output can be shorted permanently without damage Over Temperature Protection 60V max. at switch on and off at any AC line Phase Shutdown automatically without damage Turn-On Delay Time Indicators 3 sec max. at max. load, and 120VAC 60Hz, 25Hz Led #1 indicator for detection power “on” GREEN Led #2 Indicator for fault -Yellow ENVIRONMENTAL: Temperature Operation Non-operation 0 to +40°C -25 to +65°C Humidity Operation Non-Operation 5 to 90% 5 to 90% EMC FCC Class B EN55022 Class B Isolation Test Primary to Secondary: 3000VAC for 1 minute Primary to Ground: 1500VAC for 1 minute Secondary to Ground: 1500VAC for 1 minute Input Connector AC Input IEC320 C14