PHIHONG POE125U-8C

WWW.PHIHONG.COM
8 Port Gigabit Power Over Ethernet Midspan
POE125 for 10/100/1000 Base-T Networks
Features
• IEEE 802.3af Detection, Disconnect and
overload Protection
• Low Cost
• 10/100/1000 base T Compatible
Applications
• VoIP Phones
• Access Point
Safety Approvals
• cUL/UL
Mechanical Characteristics
• Length: 228mm (8.9in)
• Width: 198mm (7.8in)
Output Specifications
•
•
•
Full Power of 125W--15.4W per Port
No Power Management required
Full Protection OTP, OCP, OVP
Rack mount with optional kit
•
•
Security Systems
IP Cameras
•
CE
•
•
Height: 44.5 mm (1.75in)
Weight: 1.0Kg (2.5lbs)
Model
Number of Ports
Cisco Legacy
Support
SNMP
Management
POE125U-8
POE125U-8C
POE125U-8N
8
8
8
No
Yes
Yes
No
No
Yes
Phihong is not responsible for any error and change. Content is subject to change without notice. Please consult the
factory and visit www.phihong.com for the most up-to-date specifications.
POE125 Characteristics
INPUT:
AC Input
Voltage Range 90 to 264VAC
Input Frequency 47-63Hz
Input Current:
2.2A(RMS) max. for 90VAC
1A(RMS) max. for 240VAC
Leakage Current: 3.5mA max. @ 254VAC 60Hz
AC Inrush Current:
15A(RMS) max. for 115VAC
20A(RMS) max. for 230VAC
WWW.PHIHONG.COM
Immunity EN50082-1
ESD:
RS:
EFT:
Surge:
CS:
Voltage Dips
Harmonic:
EN61000-4-2. Level 3
EN61000-4-3. Level 2
EN61000-4-4. Level 2
EN61000-4-5. Level 3
EN61000-4-6. Level 2
EN61000-4-11
EN61000-3-2 Class A
IEEE 802.3af Interoperability
UNH Interoperability report available on
request
FEATURE:
OUTPUT:
Total Output Power
15.4W per port
Ripple and Regulation
Meets requirements of IEEE802.3af
Efficiency
75% (typical) at Max. load, and 120VAC 60Hz
Hold-up Time
20mS min. 120VAC and max. load
Transient O/P Voltage Protection
Cisco Legacy detection(Option)
No extern parts required for Legacy devices:
VoIP Phones:
7910,7912,7940,7960
Access Points:
350,1100,1200
Over Voltage/Current, Short Circuit Protection
Outputs equipped with short circuit protection and
overload protection as per 802.3af specification
The output can be shorted permanently without damage
Over Temperature Protection
60V max. at switch on and off at any AC line Phase
Shutdown automatically without damage
Turn-On Delay Time
Indicators
3 sec max. at max. load, and 120VAC 60Hz, 25Hz
Led #1 indicator for detection power “on” GREEN
Led #2 Indicator for fault -Yellow
ENVIRONMENTAL:
Temperature
Operation
Non-operation
0 to +40°C
-25 to +65°C
Humidity
Operation
Non-Operation
5 to 90%
5 to 90%
EMC
FCC Class B
EN55022 Class B
Isolation Test
Primary to Secondary: 3000VAC for 1 minute
Primary to Ground: 1500VAC for 1 minute
Secondary to Ground: 1500VAC for 1 minute
Input Connector
AC Input IEC320 C14