Magnetic Component Specification Specification Number SGE2697-1 Rev.B(120401) Rev.C (121801) This Document describes and specifies the electrical and mechanical characteristics of SGE2697-1 inverter transformer for CCFL inverter power supply . This component should be designed and manufactured in accordance with Engineering Specification LES1410T 1. Electrical Characteristics Items Inductance ( at 10Khz, 0.1V) Min Nom Max L1-2, L2-3 (uH) L6-5 (mH) LLKG2-4 ,LLKG4-6 (uH) 57.0 80.0 103.0 660 921 1180 Inductance ( at 100Khz, 1Vrms) 5.1 5.4 5.7 Should be shorted pin 6-5 Secondary Self Capacitance C6-5 (pF) 2.0 3.2 5.0 Dielectric Voltage Withstand Secondary to Core 60 Hz.,Arc-detect enabled, 5 sec. min., 200uA max. Primary to Core leakage current Primary to Secondary Operating Test V6-5 Primary driven with 80 kHz. sine wave source (pin 1-3), secondary measured with Tektronix P6015 (or equiv.).. D.C Resistance Items Min Nom Max 234 250 266 R1-2, R2-3(mΩ) 880 930 980 Rdc6-5(Ω) R1-2/R2-3 0.96 1 1.04 Balance of Primary DC resistance will be used as Bifilar winding measure tool HP4280A 1Mhz C meter, Floating mode 1200Vrms min. ( 1min. 60Hz) 1000Vrms min. 1200Vrms min. 1200Vrms min. 2. Winding Specifications Winding Sequence Wire Size & Type Number of Turns Winding Method Primary Pin 1 – 2 Pin 2-3 1S-2F 2S-3F 0.15φ, Single Insulation, 0.15φ, Single Insulation, 130°C 130°C 16 16 Bifilar Secondary Pin 6-5 6S-5F #50, Class 2 (JIS3202), 130°C 1700 3. Physical Specification & Wiring Diagram Microsemi Corporation Integrated Products. 11861 Western Ave., Garden Grove, CA 92841 tel. (714) 898-8121