MICROSEMI SGE2658-1

Magnetic Component Specification
Specification Number
SGE2658-1
Rev.A (053102)
This Document describes and specifies the electrical and mechanical characteristics of SGE2658-1 high voltage transformer
for CCFL inverter power supply. This component should be designed and manufactured in accordance with Engineering
Specification LES2110T
REVISIONS
REV. A
053102
Release
1. Electrical Characteristics
Items
L2-3, L3-4 (uH)
L6-7 (mH)
LLKG2-4 ,LLKG4-6
(uH)
C4-5 (pF)
Inductance ( at 10Khz, 0.1V)
Min
Nom
418
500
1030
1213
Inductance ( at 100Khz, 1Vrms)
27
28.5
Should be shorted pin 6-7
Secondary Self Capacitance
2.0
2.5
Dielectric Voltage Withstand
Secondary to Core
Primary to Core
Primary to Secondary
V6-7
Max
567
1396
30
3.0
60 Hz.,Arc-detect enabled, 5 sec.
min., 200uA max. leakage current
D.C Resistance
Min
Nom
Max
435
463
490
R2-3, R3-4(mΩ)
362
374
380
Rdc6-7(Ω)
R2-3/R3-4
0.96
1
1.04
Balance of Primary DC resistance will be used as Bifilar
winding measure tool
Items
HP4280A 1Mhz C meter, Floating mode
2000Vrms min. ( 1min. 60Hz)
1000Vrms min.
1000Vrms min.
Operating Test
Primary driven with 80 kHz. sine wave source (pin 2-4),
secondary measured with Tektronix P6015 (or equiv.)..
1500Vrms min.
2. Winding Specifications
Primary
Winding Sequence
Wire Size & Type
Number of Turns
Winding Method
Pin 2 – 3
2S-3F
#34, Single Insulation
130°C
31
Pin 3-4
3S-4F
#34, Single Insulation
130°C
31
Secondary
Pin 6-7
6S-7F
#46, Triple insulation
130°C
1600
Bifilar
3. Physical Specification & Wiring Diagram
4. Packaging Marking – SGE2658-1……
…… Blank -- Standard Packing ( Tray)
TR ------ Custom Packing (Tape and Reel )
Microsemi Corporation Integrated Products. 11861 Western Ave., Garden Grove, CA 92841 tel. (714) 898-8121