POWER-SYSTEMS PS-L0612A-239

DC-AC INVERTER UNIT
PS-L0612A-239 (R) (5 W SINGLE OUTPUT WITH DIMMING FUNCTION)
DESCRIPTION :
This low profile DC to AC Inverter is developed for single lamps, low power LCD
back-light. Optimized for Kyocera: TCG057QV1AA-G00
APPLICABLE LCD:
Lamp Voltage 685 Vrms
Lamp Current 4.0 mArms
Lamp Start Up Voltage 1.800 Vrms (Vin : 12 Vdc)
FEATURES :
Wide operating temperature range
Current feedback circuit
High efficiency
Low noise with voltage resonant circuit
Regulated output current
RoHS compliant (R)
TEMPERATURE & HUMIDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
DIMENSIONS :
LxBxH
-10°C ~ +70°C
-30°C ~ +85°C
95 %RH max
96 x 20 x 8 mm
Pin 1
Pin 1
Unit : mm
Weight :40 (g) typ.
Note: Please use plastic screw in case of a non-insulating mounting base!
Components
No.
1
2
3
Part Description
PCB
Connector CN1
Connector CN2
Qty.
1
1
1
Material
UL94V-0 (FR-4 or CEM-3)
53261-0590
SM02(8.0)B-BHSS-1-TB
Input side CN1:
Pin No. Symbols
Ratings
Vin
9.6 ~ 15.0 Vdc
CN 1-1
GND
CN 1-2
Vrm
t
0
~
0.5
=
OFF
/
5.0
~ 15.0 = ON
CN 1-3
Vbr
0 ~ 3 Vdc
CN 1-4
For an int ernal circuit use. Don´t connect
N.C
CN 1-5
Output side CN2:
Pin No.
Symbols
VHIGH1
CN 2-1
N.C.
CN 2-2
VLOW
CN 2-3
Note
t=1m m
Molex or equal
JST or equal
Ratings
685 Vrm s (4.0m Arm s )
0Vdc
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 1.0, 8th August 2007
DC-AC INVERTER UNIT
PS-L0612A-239 (R) (5 W SINGLE OUTPUT WITH DIMMING FUNCTION)
ELECTRICAL CHARACTERISTICS :
Conditions
Parameters
Symbols
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
Iout
Iout
Iin
F
Vopen
Note 1 :
Vin (V)
Vbr (V)
9.6 ~ 15
9.6 ~ 15
12.0
9.6 ~ 15
9.6 ~ 15
0.0
3.0
0.0
0.0
0.0
Specification
Tu (°C)
-10
-10
-10
-10
-10
~ +70
~ +70
~ +70
~ +70
~ +70
Min.
Typ.
Max.
3.5
2.0
52
1.500
4.0
2.5
0.4
60
1.800
4.5
3.0
0.65
68
-
Unit
Note
m Arm s
m Arm s
Adc
kHz
Vrm s
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked
on mechanical drawing and any conductors.
TEST CIRCUIT :
SW 1
Operation of unit
a
Operation
b
Non operation
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (2)