DC-AC INVERTER UNIT PS-DA0137-299(S) (5 W SINGLE OUTPUT) (PRELIMINARY INFORMATION) DESCRIPTION : This low profile DC/AC inverter is developed for single lamps. Optimized for CRT: CLAA102NA01CW APPLICABLE LCD: Lamp voltage 850 Vrms Lamp current 6.0 mArms Lamp start up voltage 2.400 Vrms (Vin : 12 Vdc) FEATURES : Remote ON/OFF Current balance circuit Extra high starting voltage 2D Label affixed on PCB RoHS compliant (S) TEMPERATURE & HUMIDITY : Operating temperature range Storage temperature range Humidity DIMENSIONS : -30°C ~ +80°C -30°C ~ +85°C 95 %RH max L x B x H 100 x 30 x 9 mm Pin 1 Unit : mm Weight :15 (g) typ. Material UL94V-0 (FR-4 or CEM-3) 53261-0690 SM02B-BHSS-1-TB Note t=1mm Molex or equal JST or equal Note: Please use plastic screw in case of a non-insulating mounting base! COMPONETS No. 1 2 3 Part Description PCB Connector CN1 Connector CN2 Qty. 1 1 1 Power Systems – The Power Solution Web: Email: www.Power-Systems.de [email protected] All specifications are subject to change without notice. Address: Hauptstraße 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800 Page (1) Version 1.0.3, 20th May 2014 DC-AC INVERTER UNIT PS-DA0137-299(S) (5 W SINGLE OUTPUT) (PRELIMINARY INFORMATION) OUTPUT SIDE CN2 INPUT SIDE CN1: Pin No. Symbols Ratings Vin 10.8 ~ 13.2 Vdc CN 1-1 Vin 10.8 ~ 13.2 Vdc CN 1-2 Vrmt 0 ~ 0.4 = OFF / 2.5 ~ 5.5 = ON CN 1-3 Vbr 0 ~ 5.0 Vdc CN 1-4 GND CN 1-5 GND CN 1-6 Pin No. CN 2-1 CN 2-2 Symbols Vhigh Vlow Ratings 850 Vrms (6.0 mArms) (GND) ELECTRICAL CHARACTERISTICS : Conditions Parameters Symbols Output Current Output Current Input Current Frequency Open Circuit Voltage No Load Shotdown Iout Iout Iin F Vopen Tsd Note 1 : Note 2: Note 3: Specification Vin (V) Vbr (V) Tu (°C) Min. Typ. Max. 12±1.2 12±0.6 12±1.2 12±1.2 11.4 12±1.2 0.0 5.0 0.0 0.0 0.0 0.0 -30~+80 -30~+80 -30~+80 -30~+80 -30~+80 -30~+80 5.5 40 2.200 - 6.0 15 0.5 50 2.400 1.0 6.5 0.7 60 2.700 - Unit Note mArms % Adc kHz Vrms sec Dut y 100% without load Please keep a minimum of 2mm clearance in all directions between inverter high voltage areas and any conductors as marked on mechanical drawing. Open circuit in all lamps can be detected and shut down within 3 sec. Please provide Vcc before applying any control signals into inverter. Revere the sequence during power off which is control signal off first then Vcc. TEST CIRCUIT : SW 1 Operation of unit a Operation b Non operation Power Systems – The Power Solution Web: Email: www.Power-Systems.de [email protected] All specifications are subject to change without notice. Address: Hauptstraße 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800 Page (2) Version 1.0.3, 20th May 2014