Lamp voltage 850 Vrms
Lamp current 6.0 mArms
Lamp start up voltage 2.400 Vrms (Vin : 12 Vdc)
FEATURES :
Remote ON/OFF
Current balance circuit
Extra high starting voltage
2D Label affixed on PCB
RoHS compliant (S)
TEMPERATURE & HUMIDITY :
Operating temperature range
Storage temperature range
Humidity
DIMENSIONS :
-30°C ~ +80°C
-30°C ~ +85°C
95 %RH max
L x B x H 100 x 30 x 9 mm
Pin 1
Unit : mm
Weight :15 (g) typ.
Material
UL94V-0 (FR-4 or CEM-3)
53261-0690
SM02B-BHSS-1-TB
Note
t=1mm
Molex or equal
JST or equal
Note: Please use plastic screw in case of a non-insulating mounting base!
COMPONETS
No.
1
2
3
Part Description
PCB
Connector CN1
Connector CN2
Qty.
1
1
1
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstraße 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 1.0.3, 20th May 2014
DC-AC INVERTER UNIT
PS-DA0137-299(S) (5 W SINGLE OUTPUT)
(PRELIMINARY INFORMATION)
OUTPUT SIDE CN2
INPUT SIDE CN1:
Pin No.
Symbols
Ratings
Vin
10.8 ~ 13.2 Vdc
CN 1-1
Vin
10.8 ~ 13.2 Vdc
CN 1-2
Vrmt 0 ~ 0.4 = OFF / 2.5 ~ 5.5 = ON
CN 1-3
Vbr
0 ~ 5.0 Vdc
CN 1-4
GND
CN 1-5
GND
CN 1-6
Pin No.
CN 2-1
CN 2-2
Symbols
Vhigh
Vlow
Ratings
850 Vrms (6.0 mArms)
(GND)
ELECTRICAL CHARACTERISTICS :
Conditions
Parameters
Symbols
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
No Load Shotdown
Iout
Iout
Iin
F
Vopen
Tsd
Note 1 :
Note 2:
Note 3:
Specification
Vin (V)
Vbr (V)
Tu (°C)
Min.
Typ.
Max.
12±1.2
12±0.6
12±1.2
12±1.2
11.4
12±1.2
0.0
5.0
0.0
0.0
0.0
0.0
-30~+80
-30~+80
-30~+80
-30~+80
-30~+80
-30~+80
5.5
40
2.200
-
6.0
15
0.5
50
2.400
1.0
6.5
0.7
60
2.700
-
Unit
Note
mArms
%
Adc
kHz
Vrms
sec
Dut y 100%
without load
Please keep a minimum of 2mm clearance in all directions between inverter high voltage areas
and any conductors as marked on mechanical drawing.
Open circuit in all lamps can be detected and shut down within 3 sec.
Please provide Vcc before applying any control signals into inverter.
Revere the sequence during power off which is control signal off first then Vcc.
TEST CIRCUIT :
SW 1
Operation of unit
a
Operation
b
Non operation
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstraße 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (2)
Version 1.0.3, 20th May 2014