September 2007 HYB18H256321BF–11/12/14 HYB18H256321BF–10 256-Mbit GDDR3 Graphics RAM GDDR3 Graphics RAM RoHS compliant Internet Data Sheet Rev. 0.80 Internet Data Sheet HYB18H256321BF 256-Mbit GDDR3 HYB18H256321BF–11/12/14 HYB18H256321BF–10 Revision History: 2007-09, Rev. 0.80 Page Subjects (major changes since last revision) All New Internet Data Sheet We Listen to Your Comments Any information within this document that you feel is wrong, unclear or missing at all? Your feedback will help us to continuously improve the quality of this document. Please send your proposal (including a reference to this document) to: [email protected] qag_techdoc_rev411 / 3.31 QAG / 2007-01-22 09132007-07EM-7OYI 2 Internet Data Sheet HYB18H256321BF 256-Mbit GDDR3 1 Overview This chapter lists all main features of the product family HYB18H256321BF and the ordering information. 1.1 • • • • • • • • • • • • • • Features 2.0 V VDDQ IO voltage HYB18H256321BF–10 2.0 V VDD core voltage HYB18H256321BF–10 1.8 V VDDQ IO voltage HYB18H256321BF–11/12/14 1.8 V VDD core voltage HYB18H256321BF–11/12/14 Organization: 2048K × 32 × 4 banks 4096 rows and 512 columns (128 burst start locations) per bank Differential clock inputs (CLK and CLK) CAS latencies of 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17 Write latencies of 3, 4, 5, 6, 7 Burst sequence with length of 4, 8. 4n pre fetch Short RAS to CAS timing for Writes tRAS Lockout support tWR programmable for Writes with Auto-Precharge • Data mask for write commands • Single ended READ strobe (RDQS) per byte. RDQS edgealigned with READ data • Single ended WRITE strobe (WDQS) per byte. WDQS center-aligned with WRITE data • DLL aligns RDQS and DQ transitions with Clock • Programmable IO interface including on chip termination (ODT) • Autoprecharge option with concurrent auto precharge support • 4k Refresh (32ms) • Autorefresh and Self Refresh • PG–TFBGA–136 package (10mm × 14mm) • Calibrated output drive. Active termination support • RoHS Compliant Product1) TABLE 1 Ordering Information Part Number1) Organisation Clock (MHz) Package HYB18H256321BF–11/12/14 HYB18H256321BF–10 ×32 1000/900/800/700 PG–TFBGA–136 1) HYB: designator for memory components 18H: VDDQ = 1.8 V 256: 256-Mbit density 32: Organization B: Product revision F: Lead- and Halogen-Free 1) RoHS Compliant Product: Restriction of the use of certain hazardous substances (RoHS) in electrical and electronic equipment as defined in the directive 2002/95/EC issued by the European Parliament and of the Council of 27 January 2003. These substances include mercury, lead, cadmium, hexavalent chromium, polybrominated biphenyls and polybrominated biphenyl ethers. Rev. 0.80, 2007-09 09132007-07EM-7OYI 3 Internet Data Sheet HYB18H256321BF 256-Mbit GDDR3 1.2 Description The Qimonda 256-Mbit GDDR3 Graphics RAM is a high speed memory device, designed for high bandwidth intensive applications like PC graphics systems. The chip’s 4 bank architecture is optimized for high speed. HYB18H256321BF uses a double data rate interface and a 4n-pre fetch architecture. The GDDR3 interface transfers two 32 bit wide data words per clock cycle to/from the I/O pins. Corresponding to the 4n-pre fetch a single write or read access consists of a 128 bit wide, one-clock-cycle data transfer at the internal memory core and four corresponding 32 bit wide, one-half-clockcycle data transfers at the I/O pins. Single-ended unidirectional Read and Write Data strobes are transmitted simultaneously with Read and Write data respectively in order to capture data properly at the receivers of both the Graphics SDRAM and the controller. Data strobes are organized per byte of the 32 bit wide interface. For read commands the RDQS are edge-aligned with data, and the WDQS are centeraligned with data for write commands. The HYB18H256321BF operates from a differential clock (CLK and CLK). Commands (addresses and control signals) are registered at every positive edge of CLK. Input data is registered on both edges of WDQS, and output data is referenced to both edges of RDQS. In this document references to “the positive edge of CLK” imply the crossing of the positive edge of CLK and the negative edge of CLK. Similarly, the “negative edge of CLK” refers to the crossing of the negative edge of CLK and the positive edge of CLK. References to RDQS are to be interpreted as any or all RDQS<3:0>. WDQS, DM and DQ should be interpreted in a similar fashion. Read and write accesses to the HYB18H256321BF are burst oriented. The burst length is fixed to 4 and 8 and the two least significant bits of the burst address are “Don’t Care” and internally set to LOW. Accesses begin with the registration of an ACTIVATE command, which is then followed by a READ or WRITE command. The address bits registered coincident with the ACTIVATE command are used to select the bank and the row to be accessed. The address bits registered coincident with the READ or WRITE command are used to select the bank and the column location for the burst access. Each of the 4 banks consists of 4096 row locations and 512 column locations. An AUTO PRECHARGE function can be combined with READ and WRITE to provide a self-timed row precharge that is initiated at the end of the burst access. The pipe lined, multibank architecture of the HYB18H256321BF allows for concurrent operation, thereby providing high effective bandwidth by hiding row precharge and activation time. The “On Die Termination” interface (ODT) is optimized for high frequency digital data transfers and is internally controlled. The termination resistor value can be set using an external ZQ resistor or disabled through the Extended Mode Register. The output driver impedance can be set using the Extended Mode Register. It can either be set to ZQ / 6 (auto calibration) or to 35, 40 or 45 Ohms. Auto Refresh and Power Down with Self Refresh operations are supported. An industrial standard PG–TFBGA–136 package is used which enables ultra high speed data transfer rates and a simple upgrade path from former DDR Graphics SDRAM products. Rev. 0.80, 2007-09 09132007-07EM-7OYI 4 Internet Data Sheet HYB18H256321BF 256-Mbit GDDR3 2 Configuration FIGURE 1 Ballout 256-Mbit GDDR3 Graphics RAM [Top View, MF = Low ] 9''4 9'' 966 =4 9664 '4 '4 9''4 '4 '4 9664 :'46 5'46 $ 0) 966 9'' 9''4 9664 % 9664 '4 '4 9664 9''4 & 9''4 '4 '4 9''4 9664 ' 9664 5'46 :'46 9664 9''4 '4 '0 9''4 ( 9''4 '0 '4 9''4 9'' '4 '4 &$6 ) &6 '4 '4 9'' 966 9664 '4 %$ * %$ '4 9664 966 95() $ 5$6 &.( + :( 5)0 $ 95() 966$ 5)8 5)8 9''4 - 9''4 &. &. 966$ 9''$ $ $ $ . $ $ $$3 9''$ 966 9664 '4 $ / $ '4 9664 966 9'' '4 '4 $ 0 $ '4 '4 9'' 9''4 '4 '0 9''4 1 9''4 '0 '4 9''4 9664 3 9664 9664 :'46 5'46 5'46 :'46 9664 9''4 '4 '4 9''4 5 9''4 '4 '4 9''4 9664 '4 '4 9664 7 9664 '4 '4 9664 9''4 9'' 966 1& 8 5(6(7 966 9'' 9''4 %$//287B)%*$B0 Rev. 0.80, 2007-09 09132007-07EM-7OYI 5 Internet Data Sheet HYB18H256321BF 256-Mbit GDDR3 2.1 Ball Definition and Description TABLE 2 Ball Description Ball Type Detailed Function CLK, CLK Input Clock: CLK and CLK are differential clock inputs. Address and command inputs are latched on the positive edge of CLK. Graphics SDRAM outputs (RDQS, DQs) are referenced to CLK. CLK and CLK are not internally terminated. CKE Input Clock Enable: CKE HIGH activates and CKE LOW deactivates the internal clock and input buffers. Taking CKE LOW provides Power Down. If all banks are precharged, this mode is called Precharge Power Down and Self Refresh mode is entered if a Auto Refresh command is issued. If at least one bank is open, Active Power Down mode is entered and no Self Refresh is allowed. All input receivers except CLK, CLK and CKE are disabled during Power Down. In Self Refresh mode the clock receivers are disabled too. Self Refresh Exit is performed by setting CKE asynchronously HIGH. Exit of Power Down without Self Refresh is accomplished by setting CKE HIGH with a positive edge of CLK. The value of CKE is latched asynchronously by Reset during Power On to determine the value of the termination resistor of the address and command inputs. CKE is not allowed to go LOW during a RD, a WR or a snoop burst. CS Input Chip Select: CS enables the command decoder when low and disables it when high. When the command decoder is disabled, new commands with the exception of DTERDIS are ignored, but internal operations continue. CS is one of the four command balls. RAS, CAS, WE Input Command Inputs: Sampled at the positive edge of CLK, CAS, RAS, and WE define (together with CS) the command to be executed. DQ<0:31> I/O Data Input/Output: The DQ signals form the 32 bit data bus. During READs the balls are outputs and during WRITEs they are inputs. Data is transferred at both edges of RDQS. DM<0:3> Input Input Data Mask: The DM signals are input mask signals for WRITE data. Data is masked when DM is sampled HIGH with the WRITE data. DM is sampled on both edges of WDQS. DM0 is for DQ<0:7>, DM1 is for DQ<8:15>, DM2 is for DQ<16:23> and DM3 is for DQ<24:31>. Although DM balls are input-only, their loading is designed to match the DQ and WDQS balls. RDQS<0:3> Output Read Data Strobes: RDQSx are unidirectional strobe signals. During READs the RDQSx are transmitted by the Graphics SDRAM and edge-aligned with data. RDQS have preamble and postamble requirements. RDQS0 is for DQ<0:7>, RDQS1 for DQ<8:15>, RDQS2 for DQ<16:23> and RDQS3 for DQ<24:31>. WDQS<0:3> Input Write Data Strobes: WDQSx are unidirectional strobe signals. During WRITEs the WDQSx are generated by the controller and center aligned with data. WDQS have preamble and postamble requirements. WDQS0 is for DQ<0:7>, WDQS1 for DQ<8:15>, WDQS2 for DQ<16:23> and WDQS3 for DQ<24:31>. BA<0:1> Input Bank Address Inputs: BA select to which internal bank an ACTIVATE, READ, WRITE or PRECHARGE command is being applied. BA are also used to distinguish between the MODE REGISTER SET and EXTENDED MODE REGISTER SET commands. Rev. 0.80, 2007-09 09132007-07EM-7OYI 6 Internet Data Sheet HYB18H256321BF 256-Mbit GDDR3 Ball Type Detailed Function A<0:11> Input Address Inputs: During ACTIVATE, A0-A11 defines the row address. For READ/WRITE, A2-A7 and A9 defines the column address, and A8 defines the auto precharge bit. If A8 is HIGH, the accessed bank is precharged after execution of the column access. If A8 is LOW, AUTO PRECHARGE is disabled and the bank remains active. Sampled with PRECHARGE, A8 determines whether one bank is precharged (selected by BA<0:1>, A8 LOW) or all 4 banks are precharged (A8 HIGH). During (EXTENDED) MODE REGISTER SET the address inputs define the register settings. A<0:11> are sampled with the positive edge of CLK. ZQ - ODT Impedance Reference: The ZQ ball is used to control the ODT impedance. RESET Input Reset pin: The RES pin is a VDDQ CMOS input. RES is not internally terminated. When RES is at LOW state the chip goes into full reset. The chip stays in full reset until RES goes to HIGH state. The Low to High transition of the RES signal is used to latch the CKE value to set the value of the termination resistors of the address and command inputs. After exiting the full reset a complete initialization is required since the full reset sets the internal settings to default. MF Input Mirror function pin: The MF pin is a VDDQ CMOS input. This pin must be hardwired on board either to a power or to a ground plane. With MF set to HIGH, the command and address pins are reassigned in order to allow for an easier routing on board for a back to back memory arrangement. SEN Input Enables Boundary Scan Functionality: If Boundary Scan is not used PIN should be constantly connected to GND. VREF Supply Voltage Reference: VREF is the reference voltage input. VDD, VSS Supply Power Supply: Power and Ground for the internal logic. VDDQ, VSSQ Supply I/O Power Supply: Isolated Power and Ground for the output buffers to provide improved noise immunity. NC, RFU - Please do not connect No Connect and Reserved for Future Use balls. RFM - When the MF ball is tied LOW, RFM receiver is disabled and it recommended to be driven to a static LOW state. However, either static HIGH or floating state on this pin will not cause any problem for the GDDR3 SGRAM. When the MF ball is tied HIGH, RAS(H3) becomes RFM due to mirror function and the receiver is disabled. It is recommended to be driven to a static LOW state. However, either static HIGH or floating state on this pin will not cause any problem for the GDDR3 SGRAM. 2.2 Mirror Function The GDDR3 Graphics RAM provides a ball mirroring feature that is enabled by applying a logic HIGH on ball MF. This function allows for efficient routing in a clam shell configuration. Depending of the logic state applied on MF, the command and address signals will be assigned to different balls. The default ball configuration corresponds to MF = LOW. The DC level (HIGH or LOW) must be applied on the MF pin at power up and is not allowed to change after that. Table 3 shows the ball assignment as a function of the logic state applied on MF. Rev. 0.80, 2007-09 09132007-07EM-7OYI 7 Internet Data Sheet HYB18H256321BF 256-Mbit GDDR3 TABLE 3 Ball Assignment with Mirror MF Logic State LOW HIGH H3 H10 Signal RAS F4 F9 CAS H9 H4 WE F9 F4 CS H4 H9 CKE K4 K9 A0 H2 H11 A1 K3 K10 A2 M4 M9 A3 K9 K4 A4 H11 H2 A5 K10 K3 A6 L9 L4 A7 K11 K2 A8 M9 M4 A9 K2 K11 A10 L4 L9 A11 G4 G9 BA0 G9 G4 BA1 Rev. 0.80, 2007-09 09132007-07EM-7OYI 8 Internet Data Sheet HYB18H256321BF 256-Mbit GDDR3 2.3 Truth Tables 2.3.1 Function Truth Table for more than one Activated Bank If there is more than one bank activated in the Graphics SDRAM, some commands can be performed in parallel due to the chip’s multibank architecture. The following table defines for which commands such a scheme is possible. All other transitions are illegal. Notes 1-11 define the start and end of the actions belonging to a submitted command. This table is based on the assumption that there are no other actions ongoing on bank n or bank m. If there are any actions ongoing on a third bank tRRD, tRTW and tWTR have to be taken always into account. TABLE 4 Function Truth Table I Current State Ongoing action on bank n Possible action in parallel on bank m ACTIVE ACTIVATE1) ACT, PRE, WRITE, WRITE/A, READ, READ/A2) WRITE 3) ACT, PRE, WRITE, WRITE/A, READ, READ/A4) WRITE/A5) ACT, PRE, WRITE, WRITE/A, READ6) 7) READ ACT, PRE, WRITE, WRITE/A, READ, READ/A8) READ/A9) ACT, PRE, WRITE, WRITE/A, READ, READ/A 8) PRECHARGE10) ACT, PRE, WRITE, WRITE/A, READ, READ/A11) PRECHARGE ALL 10) 12) POWER DOWN ENTRY IDLE - ACTIVATE 1) ACT POWER DOWN ENTRY 12) - AUTO REFRESH13) - SELF REFRESH ENTRY 12) 14) MODE REGISTER SET (MRS) EXTENDED MRS POWER DOWN SELF REFRESH 14) - POWER DOWN EXIT15) SELF REFRESH EXIT - 16) - 1) Action ACTIVATE starts with issuing the command and ends after tRCD. 2) During action ACTIVATE an ACT command on another bank is allowed considering tRRD, a PRE command on another bank is allowed any time. WR, WR/A, RD and RD/A are always allowed. 3) Action WRITE starts with issuing the command and ends tWR after the first pos. edge of CLK following the last falling WDQS edge. 4) During action WRITE an ACT or a PRE command on another bank is allowed any time. A new WR or WR/A command on another bank must be separated by at least one NOP from the ongoing WRITE. RD or RD/A are not allowed before tWTR is met. 5) Action WRITE/A starts with issuing the command and ends tWR after the first positive edge of CLK following the last falling WDQS edge. 6) During action WRITE/A an ACT or a PRE command on another bank is allowed any time. A new WR or WR/A command on another bank has to be separated by at least one NOP from the ongoing command. RD is not allowed before or tWTR is met. RD/A is not allowed during an ongoing WRITE/A action. 7) Action READ starts with issuing the command and ends with the first positive edge of CLK following the last falling edge of RDQS. 8) During action READ and READ/A an ACT or a PRE command on another bank is allowed any time. A new RD or RD/A command on another bank has to be separated by at least one NOP from the ongoing command. A WR or WR/A command on another bank has to meet tRTW. 9) Action READ/A starts with issuing the command and ends with the first positive edge of CLK following the last falling edge of RDQS. 10) Action PRECHARGE and PRECHARGE ALL start with issuing the command and ends after tRP. Rev. 0.80, 2007-09 09132007-07EM-7OYI 9 Internet Data Sheet HYB18H256321BF 256-Mbit GDDR3 11) During Action ACTIVE an ACT command on another banks is allowed considering tRRD . A PRE command on another bank is allowed any time. WR, WR/A, RD and RD/A are always allowed. 12) During POWER DOWN and SELF REFRESH only the EXIT commands are allowed. 13) AUTO REFRESH starts with issuing the command and ends after tRFC. 14) Actions MODE REGISTER SET and EXTENDED MODE REGISTER SET start with issuing the command and ends after tMRD. 15) Action POWER DOWN EXIT starts with issuing the command and ends after tXPN. 16) Action SELF REFRESH EXIT starts with issuing the command and ends after tXSC. 2.4 Function Truth Table for CKE TABLE 5 Function Truth Table II (CKE Table) CKE N-1 CKE n CURRENT STATE COMMAND ACTION L L Power Down X Stay in Power Down Self Refresh X Stay in Self Refresh Power Down DESEL or NOP Exit Power Down Self Refresh DESEL or NOP Exit Self Refresh 5 L H H L All Banks Idle DESEL or NOP Entry Precharge Power Down Bank(s) Active DESEL or NOP Entry Active Power Down All Banks Idle Auto Refresh Entry Self Refresh Notes 1. 2. 3. 4. 5. CKEn is the logic step at clock edge n; CKEn-1 was the state of CKE at the previous clock edge. Current state is the state of the GDDR3 Graphics RAM immediately prior to clock edge n. COMMAND is the command registered at clock edge n, and ACTION is a result of COMMAND. All states and sequences not shown are illegal or reserved. DESEL or NOP commands should be issued on any clock edges occurring during the tXSR period. A minimum of 1000 clock cycles is required before applying any other valid command. Rev. 0.80, 2007-09 09132007-07EM-7OYI 10 Internet Data Sheet HYB18H256321BF 256-Mbit GDDR3 3 Functional Description 3.1 Mode Register Set Command (MRS) The Mode Register stores the data for controlling the operation modes of the memory. It programs CAS latency, test mode, DLL Reset , the value of the Write Latency and the Burst length. The Mode Register must be written after power up to operate the SGRAM. During a ModeRegister Set command the address inputs are sampled and stored in the Mode Register. The Mode Register content can only be set or changed when the chip is in Idle state. For non-READ commands following a Mode Register Set a delay of tMRD must be met. The Mode Register Bitmap is supported in two configurations. The first configuration is intended to support the Mid-RangeSpeed application. The second configuration supports higher clock cycles for CAS latency and is therefore prepared to support high-speed application. The selected configuration is defined by Bit0 of EMRS2. FIGURE 2 Mode Register Set Command &/. &/. &.( &6 5$6 &$6 :( $$ %$ &2' &2'&RGHWREHORDGHGLQWR WKHUHJLVWHU %$ Rev. 0.80, 2007-09 09132007-07EM-7OYI 'RQ W&DUH 11 Internet Data Sheet HYB18H256321BF 256-Mbit GDDR3 FIGURE 3 Mode Register Bitmap for Mid-Range-Speed Application (!**$, *$, +()*$* )*#% %(#" )*#% #% ""%* () )* *$, +()*,& )* *$, % )'+$*!" ) Rev. 0.80, 2007-09 09132007-07EM-7OYI 12 Internet Data Sheet HYB18H256321BF 256-Mbit GDDR3 FIGURE 4 Mode Register Bitmap for High-Speed Application *$, (!**$, +()*$* )*#% #% %(#" )*#% ""%* () )* *$, +()*,& )* *$, % )'+$*!" ) FIGURE 5 Mode Register Set Timing CLK# CLK Com. PA NOP MRS t RP NOP NOP A.C. NOP t MRD tMRDR MRS: MRS command PA: PREALL command A.C.: Any other command as READ RD: READ command Don't Care Rev. 0.80, 2007-09 09132007-07EM-7OYI RD 13 Internet Data Sheet HYB18H256321BF 256-Mbit GDDR3 3.1.1 Burst length Read and Write accesses to the GDDR3 Graphics RAM are burst oriented with burst length of 4 and 8. This value must be programmed using the Mode Register Set command (A0 .. A2). The burst length determines the number of column locations that can be accessed for a given READ or WRITE command. When a READ or WRITE command is issued, a block of columns equal to the burst length is effectively selected. All accesses for that burst take place within this block if a boundary is reached. The starting location within this block is determined by the two least significant bits A0 and A1 which are set internally to the fixed value of zero each.Reserved states should not be used, as unknown operation or incompatibility with future versions may result. 3.1.2 Burst type Accesses within a given bank must be programmed to be sequential. This is done using the Mode Register Set command (A3). This device does not support the burst interleave mode. TABLE 6 Burst Definition Burst Length Starting Column Address Order of Accesses within a Burst (Type = sequential) A2 A1 A0 4 — X X 0-1-2-3 8 0 X X 0-1-2-3-4-5-6-7 1 X X 4-5-6-7-0-1-2-3 The value applied at the balls A0 and A1 for the column address is “Don’t care”. 3.1.3 CAS Latency The CAS latency is the delay, in clock cycles, between the registration of a READ command and the availability of the first bit of output data. If a READ command is registered at clock edge n, and the latency is m clocks, the data will be available nominally coincident with clock edge n+m. The two Mode Register setups support different CAS Latencies in terms of clock cycles. The mid-range-speed Mode Register supports latencies from 7 to 14. The high-speed Mode Register supports latencies from 10 to 17. The active Mode Register setup is selected by Bit0 of EMRS2. 3.1.4 Write Latency The WRITE latency, WL, is the delay, in clock cycles, between the registration of a WRITE command and the availability of the first bit of input data. Rev. 0.80, 2007-09 09132007-07EM-7OYI 14 Internet Data Sheet HYB18H256321BF 256-Mbit GDDR3 TABLE 7 ON/OFF mode of DQ/DM receivers WL DQ/DM-Receivers 3-4 Receivers are always on 5-6-7 Receivers are off and will be switched on by Write command and will be switched off again after WL+BL The ON/OFF state of the DQ/DM receivers depends on the Write Latency. The dependence is given in Table 7. 3.1.5 Test mode The normal operating mode is selected by issuing a Mode Register Set command with bit A7 set to zero and bits A0-A6 and A8-A11 set to the desired value. 3.1.6 DLL Reset The normal operating mode is selected by issuing a Mode Register Set command with bit A8 set to zero and bits A0-A7 and A9-A11 set to the desired values. A DLL Reset is initiated by issuing a Mode Register Set command with bit A8 set to one and bits A0-A7 and A9-A11 set to the desired values. The GDDR3 Graphics RAM returns automatically in the normal mode of operations once the DLL reset is completed. Rev. 0.80, 2007-09 09132007-07EM-7OYI 15 Internet Data Sheet HYB18H256321BF 256-Mbit GDDR3 3.2 Extended Mode Register Set Command (EMRS1) The Extended Mode Register is used to set the output driver impedance value, the termination impedance value, the Write Recovery time value for Write with Autoprecharge. It is used as well to enable/disable the DLL, to issue the Vendor ID and to enable/disable the Low Power mode. There is no default value for the Extended Mode Register. Therefore it must be written after power up to operate the GDDR3 Graphics RAM. The Extended Mode Register can be programmed by performing a normal Mode Register Set operation and setting the BA0 bit to HIGH and BA1 bits to LOW. All other bits of the EMR register are reserved and should be set to LOW. The Extended Mode Register must be loaded when all banks are idle and no burst are in progress. The controller must wait the specified time tMRD before initiating any subsequent operation (Figure 9). The timing of the EMRS command operation is equivalent to the timing of the MRS command operation. FIGURE 6 Extended Mode Register Set Command &/. &/. &.( &6 5$6 &$6 :( $$ &2' %$ %$ &2'&RGHWREHORDGHGLQWR WKHUHJLVWHU Rev. 0.80, 2007-09 09132007-07EM-7OYI 'RQ W&DUH 16 Internet Data Sheet HYB18H256321BF 256-Mbit GDDR3 FIGURE 7 Extended Mode Register Bitmap for Mid-Range-Speed Application %$ %$ $ $ 9 $ $ 5)8 $ $ :5 '// $ :5 $ $ $ 5WW $ 'DWD= 2XWSXW'ULYHU ,PSHGDQFH '// (QDEOH $ $ (QDEOH $XWRFDO 'LVDEOH $ $ $ 9HQGRU,' 2II 2Q $ $ $ :5 $ $ 7HUPLQDWLRQ 2'7GLVDEOHG 5)8 =4 =4'HIDXOW (;7(1'('B02'(B5(*,67(5BB0,'B There are two bitmaps for the Extended Mode Register. One bitmap shown in Figure 7 is supposed to support Mid-Speed applications. The other bitmap shown in Figure 8 is more focused on the high-range-speed application. Both bitmaps distinguish different numbers in supported Write Recovery clock cycles. The mid-range bit map provides WR cycles from 4 to 11.The high-speed bitmap supports WR from 7 to 13. Rev. 0.80, 2007-09 09132007-07EM-7OYI 17 Internet Data Sheet HYB18H256321BF 256-Mbit GDDR3 FIGURE 8 Extended Mode Register Bitmap for High-Speed Application %$ %$ $ $ 9 $ $ 5)8 $ $ :5 '// 9HQGRU,' 2II 2Q $ :5 $ $ $ 5WW $ 'DWD= 2XWSXW'ULYHU ,PSHGDQFH '// (QDEOH $ (QDEOH $XWRFDO 'LVDEOH 2KPV $ $ $ $ $ $ 5)8 Notes $ 2KPV 2KPV :5 $ $ 7HUPLQDWLRQ 2'7GLVDEOHG 5)8 =4 =4 'HIDXOW option implemented in the device) or no action is taken by the device (if option not implemented). 5. WR (write recovery time for auto precharge) in clock cycles is calculated by dividing tWR (in ns) and rounding up to the next integer (WR[cycles] = tWR[ns] / tCK[ns]). The mode register must be programmed to this value. 1. These settings are for debugging purposes only. 2. Default termination values at Power Up. 3. The ODT disable function disables all terminators on the device. 4. If the user activates bits in the extended mode register in an optional field, either the optional field is activated (if FIGURE 9 Extended Mode Register Set Timing CLK# CLK Command PA NOP EMRS NOP t RP A.C. t MRD A.C.: Any command Don't Care Rev. 0.80, 2007-09 09132007-07EM-7OYI NOP 18 EMRS: Extended MRS command PA: PREALL command Internet Data Sheet HYB18H256321BF 256-Mbit GDDR3 3.2.1 DLL enable The DLL must be enabled for normal operation. DLL enable is required during power-up initialization and upon returning to normal operation after having disabled the DLL. (When the device exits self-refresh mode, the DLL is enabled automatically). Anytime the DLL is enabled, 1000 cycles must occur before a READ command can be issued. 3.2.2 WR The WR parameter is programmed using the register bits A4, A5 and A7. This integer parameter defines as a number of clock cycles the Write Recovery time in a Write with Autoprecharge operation. The following inequality has to be complied with: WR * tCK ≥ tWR, where tCK is the clock cycle time. The high-speed bitmap supports WR from 7 to 13. The mid-range bitmap provides WR cycles from 4 to 11. 3.2.3 Termination Rtt The data termination, Rtt, is used to set the value of the internal termination resistors. The GDDR3 DRAM supports ZQ / 4 and ZQ / 2 termination values. The termination may also be disabled for testing and other purposes. 3.2.4 Output Driver Impedance The Output Driver Impedance extended mode register is used to set the value of the data output driver impedance. When the auto calibration is used, the output driver impedance is set nominally to ZQ / 6. If the Output Driver Impendance is changed to 30, 40 or 45 Ohms the user needs to issue 16 AREF commands separated by tRFC consecutively to make the change effective. The user must be aware that the Command bus needs to be stable for a time of tKO after each AREF. 3.2.5 Vendor Code and Revision Identification The Manufacturer Vendor Code is selected by issuing an Extended Mode Register Set command with bit A10 set to 1 and bits A0-A9 and A11 set to the desired value. When the Vendor Code function is enabled the GDDR3 DRAM will provide the Qimonda vendor code on DQ[3:0] and the revision identification on DQ[7:4]. The code will be driven onto the DQ bus after tRIDon following the EMRS command that sets A10 to 1. The Vendor Code and Revision ID will be driven on DQ[7:0] until a new EMRS command is issued with A10 set back to 0. After tRDoff following the second EMRS command, the data bus is driven back to HIGH. This second EMRS command must be issued before initiating any subsequent operation. Violating this requirement will result in unspecified operation. TABLE 8 Revision ID and Vendor Code Revision Identification Qimonda Vendor Code DQ[7:4] DQ[3:0] 0011 0010 Note: Please refer to Revision Release Note for Revision ID value. Rev. 0.80, 2007-09 09132007-07EM-7OYI 19 Internet Data Sheet HYB18H256321BF 256-Mbit GDDR3 FIGURE 10 Timing of Vendor Code and Revision ID Generation on DQ[7:0] 0 1 2 3 4 5 6 7 8 9 10 Com. EMRS N/D N/D N/D N/D N/D EMRS N/D N/D N/D N/D A[9:0], A11 Add CLK# CLK Add A10 t t RIDon RIDoff RDQS DQ[7:0] Vendor Code and Revision ID EMRS: Extended Mode Register Set Command Add: Address N/D: NOP or Deselect Don't Care Rev. 0.80, 2007-09 09132007-07EM-7OYI 20 Internet Data Sheet HYB18H256321BF 256-Mbit GDDR3 3.3 Extended Mode Register 2 Set Command (EMRS2) The Extended Mode Register 2 is used to define the active bitmap of the Mode Register and the Extended Mode Register. The Extended Mode Register 2 must be written after power up to operate the GDDR3 Graphics RAM. The Extended Mode Register 2 can be programmed by performing a normal Mode Register Set operation and setting the BA1 bit to HIGH and BA0 bits to LOW. All bits defined as RFU in the bitmap are reserved and must be set to LOW. The Extended Mode Register 2 must be loaded when all banks are idle and no burst are in progress. The controller must wait the specified time tMRD before initiating any subsequent operation. The timing of the EMRS2 command operation is equivalent to the timing of the MRS command operation. FIGURE 11 Extended Mode Register 2 Set Command &/. &/. &.( &6 5$6 &$6 :( $$ &2' %$ &2'&RGHWREHORDGHGLQWR WKHUHJLVWHU %$ 'RQ W&DUH FIGURE 12 Extended Mode Register 2 Bitmap Rev. 0.80, 2007-09 09132007-07EM-7OYI 21 Internet Data Sheet HYB18H256321BF 256-Mbit GDDR3 3.3.1 App Mode The GDDR3 Graphics RAM provides two bitmaps for the Mode Register and the Extended Mode Register respectively. The Bitmaps are shown in the MRS and EMRS chapters. The Bit0 of the Extended Mode Regsiter 2 defines which one of the two bitmaps is active. Bit0 set to LOW enables the midrange bitmap and Bit0 set to HIGH enables the High-Speed bitmap. Rev. 0.80, 2007-09 09132007-07EM-7OYI 22 Internet Data Sheet HYB18H256321BF 256-Mbit GDDR3 4 Electrical Characteristics 4.1 Absolute Maximum Ratings and Operation Conditions TABLE 9 Absolute Maximum Ratings Parameter Symbol VDD VDDQ VIN VOUT TSTG TJ IOUT Power Supply Voltage Power Supply Voltage for Output Buffer Input Voltage Output Voltage Storage Temperature Junction Temperature Short Circuit Output Current Rating Unit Min. Max. -0.5 2.5 V -0.5 2.5 V -0.5 2.5 V -0.5 2.5 V -55 +150 °C — +125 °C — 50 mA Attention: Stresses above the max. values listed here may cause permanent damage to the device. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. Maximum ratings are absolute ratings; exceeding only one of these values may cause irreversible damage to the integrated circuit. 4.2 DC Operation Conditions 4.2.1 Recommended Power & DC Operation Conditions TABLE 10 Power & DC Operation Conditions (0 °C ≤ Tc ≤ 85 °C) Parameter Power Supply Voltage Power Supply Voltage for I/O Buffer Rev. 0.80, 2007-09 09132007-07EM-7OYI Symbol Limit Values VDD, VDDA VDDQ 23 Unit Note Min. Typ. Max. 1.9 2.0 2.1 V 1)2) 1.9 2.0 2.1 V 1)2) Internet Data Sheet HYB18H256321BF 256-Mbit GDDR3 Parameter Symbol Limit Values Unit Note Min. Typ. Max. 1.7 1.8 1.9 V 1)3) 1.7 1.8 1.9 V 1)3) 0.69*VDDQ — 0.71*VDDQ V 4) — — 0.8 V –5.0 — +5.0 μΑ –5.0 — +5.0 μΑ Output leakage current –5.0 — 1) VDDQ tracks with VDD. AC parameters are measured with VDD and VDDQ tied together. +5.0 μΑ Power Supply Voltage Power Supply Voltage for I/O Buffer Reference Voltage Output Low Voltage Input leakage current CLK Input leakage current VDD, VDDA VDDQ VREF VOL(DC) IIL IILC IOL 5) 5) 2) HYB18H256321BF–11/12/14 3) HYB18H256321BF–10 4) VREF is expected to equal 70% of VDDQ for the transmitting device and to track variations in the DC level of the same. Peak-to-peak noise on VREF may not exceed ±2% VREF (DC). Thus, from 70% of VDDQ, VREF is allowed ± 19mV for DC error and an additional ± 27mV for AC noise. 5) IIL and IOL are measured with ODT disabled. 4.3 DC & AC Logic Input Levels TABLE 11 DC & AC Logic Input Levels (0 °C ≤ Tc ≤ 85 °C) Parameter Input logic high voltage, DC Input logic low voltage, DC Input logic high voltage, AC Input logic low voltage, AC Input logic high, DC, RESET pin Input logic low, DC, RESET pin Input Logic High, DC, MF pin Input Logic Low,DC, MF pin Symbol VIH(DC) VIL(DC) VIH(AC) VIL(AC) VIHR(DC) VILR(DC) VIHMF(DC) VILMF(DC) Limit Values Unit Note Min. Max. VREF + 0.15 — V 1) — VREF -0.15 V 1) VREF + 0.25 — V 2)3) — V 2)3) VDD VREF - 0.25 VDDQ + 0.3 0.35 × VDDQ VDD + 0.3 –0.3 0 0.65 × VDDQ -0.3 V V V 4) V 1) The DC values define where the input slew rate requirements are imposed, and the input signal must not violate these levels in order to maintain a valid level. 2) Input slew rate = 3 V/ns. If the input slew rate is less than 3 V/ns, input timing may be compromised. All slew rates are measured between VIL(DC) and VIH(DC). 3) VIH overshoot: VIH(max) = VDDQ+0.5V for a pulse width ≤ 500ps and the pulse width cannot be greater than 1/3 of the cycle rate. VIL undershoot: VIL(min) = 0 V for a pulse width ≤ 500ps and the pulse width cannot be greater than 1/3 of the cycle rate. 4) The MF pin must be hard-wired on board to either VDD or VSS. Rev. 0.80, 2007-09 09132007-07EM-7OYI 24 Internet Data Sheet HYB18H256321BF 256-Mbit GDDR3 4.4 Differential Clock DC and AC Levels TABLE 12 Differential Clock DC and AC Input conditions (0 °C ≤ Tc ≤ 85 °C) Parameter Symbol Clock Input Mid-Point Voltage, CLK and CLK Clock Input Voltage Level, CLK and CLK Clock DC Input Differential Voltage, CLK and CLK Limit Values VMP(DC) VIN(DC) VID(DC) Note Min. Max. 0.7 × VDDQ – 0.10 0.7 × VDDQ + 0.10 V 1) 0.42 VDDQ + 0.3 VDDQ V 1) V 1) VDDQ + 0.5 0.7 × VDDQ + 0.15 V 1)2) 0.3 Clock AC Input Differential Voltage, CLK and CLK VID(AC) Unit 0.5 1)3) AC Differential Crossing Point Input Voltage VIX(AC) 0.7 × VDDQ – 0.15 V 1) All voltages referenced to VSS. 2) VID is the magnitude of the difference between the input level on CLK and the input level on CLK. 3) The value of VIX is expected to equal 0.7 × VDDQ of the transmitting device and must track variations in the DC level of the same. 4.5 Output Test Conditions FIGURE 13 Output Test Circuit VDDQ 60 Ohm DQ DQS Rev. 0.80, 2007-09 09132007-07EM-7OYI Test point 25 Internet Data Sheet HYB18H256321BF 256-Mbit GDDR3 4.6 Pin Capacitances TABLE 13 Pin Capacitances (VDDQ = 1.8 V, TA = 25°C, f = 1 MHz) Parameter Symbol Min. Max. Unit Input capacitance: CI,CCK A0-A11, BA0-1, CKE, CS, CAS, RAS, WE, CKE, RES,CLK,CLK 1.0 2.5 pF Input capacitance: DQ0-DQ31, RDQS0-RDQS3, WDQS0-WDQS3, DM0-DM3 2.0 3.0 pF CIO 4.7 Driver current characteristics 4.7.1 Driver IV characteristics at 40 Ohms Note Figure 14 represents the driver Pull-Down and Pull-Up IV characteristics under process, voltage and temperature best and worst case conditions. The actual Driver Pull-Down and Pull-Up current must lie between these two bounding curves. The value of the external ZQ resistor is 240 Ω, setting the nominal driver output impedance to 40 Ω. FIGURE 14 40 Ohm Driver Pull-Down and Pull-Up Characteristics 3XOO8S&KDUDFWHUVWLFV 3XOO'RZQ&KDUDFWHUVWLFV ,RXWP$ ,RXWP$ 9''49RXW9 9RXW9 Table 14 lists the numerical values of the minimum and maximum allowed values of the output driver Pull-Down and Pull-Up IV characteristics. Rev. 0.80, 2007-09 09132007-07EM-7OYI 26 Internet Data Sheet HYB18H256321BF 256-Mbit GDDR3 TABLE 14 Programmed Driver IV Characteristics at 40 Ohm Voltage (V) Pull-Down Current (mA) Pull-Up Current (mA) Minimum Maximum Minimum Maximum 0.1 2.32 3.04 -2.44 -3.27 0.2 4.56 5.98 -4.79 -6.42 0.3 6.69 8.82 -7.03 -9.45 0.4 8.74 11.56 -9.18 -12.37 0.5 10.70 14.19 -11.23 -15.17 0.6 12.56 16.72 -13.17 -17.83 0.7 14.34 19.14 -15.01 -20.37 0.8 16.01 21.44 -16.74 -22.78 0.9 17.61 23.61 -18.37 -25.04 1.0 19.11 26.10 -19.90 -27.17 1.1 20.53 28.45 .21.34 -29.17 1.2 21.92 30.45 -22.72 -31.25 1.3 23.29 32.73 -24.07 -33.00 1.4 24.65 34.95 -25.40 -35.00 1.5 26.00 37.10 -26.73 -37.00 1.6 27.35 39.15 -28.06 -39.14 1.7 28.70 41.01 -29.37 -41.25 1.8 30.08 42.53 -30.66 -43.29 1.9 — 43.71 — -45.23 2.0 — 44.89 — -47.07 4.7.2 Termination IV Characteristic at 60 Ohms Figure 15 represents the DQ termination Pull-Up IV characteristic under process, voltage and temperature best and worst case conditions. The actual DQ termination Pull-Up current must lie between these two bounding curves. The value of the external ZQ resistor is 240 Ω, setting the nominal DQ termination impedance to 60 Ω. (Extended Mode Register programmed to ZQ/4). Rev. 0.80, 2007-09 09132007-07EM-7OYI 27 Internet Data Sheet HYB18H256321BF 256-Mbit GDDR3 FIGURE 15 60 Ohm Active Termination Characteristic 2KP7HUPLQDWLRQ&KDUDFWHUVWLFV ,RXWP$ 9''49RXW9 Table 15 lists the numerical values of the minimum and maximum allowed values of the output driver termination IV characteristic. TABLE 15 Programmed Terminator Characteristics at 60 Ohm Voltage (V) Terminator Pull-Up Current (mA) Minimum Maximum 0.1 -1.63 -2.18 0.2 -3.19 0.3 0.4 Voltage (V) Terminator Pull-Up Current (mA) Minimum Maximum 1.1 -14.23 -19.45 -4.28 1.2 -15.14 -20.83 -4.69 -6.30 1.3 -16.04 -22.00 -6.12 -8.25 1.4 -16.94 -23.33 0.5 -7.49 -10.11 1.5 -17.82 -24.67 0.6 -8.78 -11.89 1.6 -18.70 -26.09 0.7 -10.01 -13.58 1.7 -19.58 -27.50 0.8 -11.16 -15.19 1.8 -20.44 -28.86 0.9 -12.25 -16.69 1.9 — -30.15 1.0 -13.27 -18.11 2.0 — -31.38 Rev. 0.80, 2007-09 09132007-07EM-7OYI 28 Internet Data Sheet HYB18H256321BF 256-Mbit GDDR3 4.8 Termination IV Characteristic at 120 Ohms Figure 16 represents the DQ or ADD/CMD termination Pull-Up IV characteristic under process, voltage and temperature best and worst case conditions. The actual termination Pull-Up current must lie between these two bounding curves. The value of the external ZQ resistor is 240 Ω, setting the nominal termination impedance to 120 Ω. (Extended Mode Register programmed to ZQ/2 for DQ terminations or CKE = 0 at the RES transition during Power-Up for ADD/CMD terminations). FIGURE 16 120 Ohm Active Termination Characteristic 2KP7HUPLQDWLRQ&KDUDFWHUVWLFV ,RXWP$ 9''49RXW9 Table 16 lists the numerical values of the minimum and maximum allowed values of the termination IV characteristic. TABLE 16 Programmed Terminator Characteristics of 120 Ohm Voltage (V) Terminator Pull-Up Current (mA) Minimum Voltage (V) Maximum Terminator Pull-Up Current (mA) Minimum Maximum 0.1 -0.81 -1.09 1.1 -7.11 -9.72 0.2 -1.60 -2.14 1.2 -7.57 -10.42 0.3 -2.34 -3.15 1.3 -8.02 -11.00 0.4 -3.06 -4.12 1.4 -8.47 -11.67 0.5 -3.74 -5.06 1.5 -8.91 -12.33 0.6 -4.39 -5.94 1.6 -9.35 -13.05 0.7 -5.00 -6.79 1.7 -9.79 -13.75 0.8 -5.58 -7.59 1.8 -10.22 -14.43 0.9 -6.12 -8.35 1.9 — -15.08 1.0 -6.63 -9.06 2.0 — -15.69 Rev. 0.80, 2007-09 09132007-07EM-7OYI 29 Internet Data Sheet HYB18H256321BF 256-Mbit GDDR3 4.9 Termination IV Characteristic at 240 Ohms Figure 17 represents the ADD/CMD termination Pull-Up IV characteristic under process, voltage and temperature best and worst case conditions. The actual ADD/CMD termination Pull-Up current must lie between these two bounding curves. The value of the external ZQ resistor is 240 Ω, setting the nominal termination impedance to 240 Ω. (CKE = 1at the RES transition during Power-Up for ADD/CMD terminations). FIGURE 17 240 Ohm Active Termination Characteristic 2KP7HUPLQDWLRQ&KDUDFWHUVWLFV ,RXWP$ 9''49RXW9 Table 17 lists the numerical values of the minimum and maximum allowed values of the ADD/CMD termination IV characteristic. TABLE 17 Programmed Terminator Characteristics at 240 Ohm Voltage (V) Terminator Pull-Up Current (mA) Minimum Maximum 0.1 -0.41 -0.55 0.2 -0.80 -1.07 0.3 -1.17 0.4 0.5 Voltage (V) Terminator Pull-Up Current (mA) Minimum Maximum 1.1 -3.56 -4.86 1.2 -3.79 -5.21 -1.58 1.3 -4.01 -5.50 -1.53 -2.06 1.4 -4.23 -5.83 -1.87 -2.53 1.5 -4.46 -6.17 0.6 -2.20 -2.97 1.6 -4.68 -6.52 0.7 -2.50 -3.40 1.7 -4.90 -6.88 0.8 -2.79 -3.80 1.8 -5.11 -7.21 0.9 -3.06 -4.17 1.9 — -7.54 1.0 -3.32 -4.53 2.0 — -7.85 Rev. 0.80, 2007-09 09132007-07EM-7OYI 30 Internet Data Sheet HYB18H256321BF 256-Mbit GDDR3 4.10 Operating Current Measurement Conditions TABLE 18 Operating Current Measurement Conditions Symbol Parameter/Condition IDD0 Operating Current - One bank, Activate - Precharge tCK=min(tCK), tRC=min(tRC) Databus inputs are SWITCHING; Address and control inputs are SWITCHING, CS = HIGH between valid commands. IDD1 Operating Current - One bank, Activate - Read - Precharge One bank is accessed with tCK=min(tCK), tRC=min(tRC), CL = CL(min), Address and control inputs are SWITCHING; CS = HIGH between valid commands. Iout=0 mA IDD2P Precharge Power-Down Standby Current All banks idle, power-down mode, CKE is LOW, tCK=min(tCK), Data bus inputs are STABLE (HIGH). IDD2F Precharge Floating Standby Current All banks idle; CS is HIGH, CKE is HIGH, tCK=min(tCK); Address and control inputs are SWITCHING; Data bus input are STABLE (HIGH). IDD2Q Precharge Quiet Standby Current CS is HIGH, all banks idle, CKE is HIGH, tCK=min(tCK), Address and other control inputs STABLE (HIGH), Data bus inputs are STABLE (HIGH). IDD3P Active Power-Down Standby Current One bank active, CKE is LOW, Address and control inputs are STABLE (HIGH); Data bus inputs are STABLE (HIGH); standard active power-down mode. IDD3N Active Standby Current One bank active, CS is HIGH, CKE is HIGH, tRAS= tRAS,max, tCK=min(tCK); Address and control inputs are SWITCHING; Data bus inputs are SWITCHING. IDD4R Operating Current - Burst Read One bank active; Continuous read bursts, CL = CL(min); tCK=min(tCK); tRAS= tRAS,max; Address and control inputs are SWITCHING; Iout = 0 mA. IDD4W Operating Current - Burst Write One bank active; Continuous write bursts; tCK=min(tCK); Address and control inputs are SWITCHING; Data bus inputs are SWITCHING. IDD5B Burst Auto Refresh Current Refresh command at tRFC=min(tRFC); tCK=min(tCK); CKE is HIGH, CS is HIGH between all valid commands; Other command and address inputs are SWITCHING; Data bus inputs are SWITCHING. IDD5D Distributed Auto Refresh Current tCK=tCKmin; Refresh command every tREFI; CKE is HIGH, CS is HIGH between valid commands; Other command and address inputs are SWITCHING; Data bus inputs are SWITCHING. IDD6 Self Refresh Current CKE ≤ max(VIL), external clock off, CK and CK LOW; Address and control inputs are STABLE (HIGH); Data Bus inputs are STABLE (HIGH). IDD7 Operating Bank Interleave Read Current All banks interleaving with CL = CL(min); tRCD = tRCDRD(min); tRRD = tRRD(min); Iout=0 mA; Address and control inputs are STABLE (HIGH) during DESELECT; Data bus inputs are SWITCHING. Rev. 0.80, 2007-09 09132007-07EM-7OYI 31 Internet Data Sheet HYB18H256321BF 256-Mbit GDDR3 Notes 1. 0 °C ≤ Tc ≤ 85 °C 2. Data Bus consists of DQ, DM, WDQS. 3. Definitions for IDD: LOW is defined as VIN = 0.4 × VDDQ; HIGH is defined as VIN = VDDQ; TABLE is defined as inputs are stable at a HIGH level. SWITCHING is defined as inputs are changing between HIGH and LOW every clock cycle for address and control signals, and inputs changing 50% of each data transfer for DQ signals. Rev. 0.80, 2007-09 09132007-07EM-7OYI 32 Internet Data Sheet HYB18H256321BF 256-Mbit GDDR3 4.11 AC Timings for HYB18H256321BF TABLE 19 Timing Parameters for HYB18H256321BF Parameter CAS latency Symbol Limit Values –10 Min. Unit Note –11 Max. Min. –12 Max. Min. –14 Max. Min. Max. Clock and Clock Enable System frequency CL=13 CL= 12 CL= 11 CL =10 CL = 9 CL = 8 CL = 7 Clock high level width Clock low-level width Minimum clock half period fCK13 fCK12 fCK11 fCK10 fCK9 fCK8 fCK7 tCH tCL tHP — — — — — — — — MHz TBD 1000 — — — — — — MHz 1) 400 900 400 900 400 800 400 700 MHz 2) 400 800 400 800 400 700 400 650 MHz 1) 400 700 400 700 400 650 400 600 MHz 1) 400 600 400 600 400 550 400 500 MHz 1) 400 550 400 550 400 500 400 450 MHz 1) 0.45 0.55 0.45 0.55 0.45 0.55 0.45 0.55 0.45 0.55 0.45 0.55 0.45 0.55 0.45 0.55 0.45 — 0.45 — 0.45 — 0.45 — tCK tCK tCK tIS tIH tIP 0.24 — 0.27 — 0.3 — 0.35 — ns 0.24 — 0.27 — 0.3 — 0.35 — ns 0.7 — 0.7 — 0.7 — 0.7 — tCK tMRD tMRDR 6 — 6 — 6 — 6 — 12 — 12 — 12 — 12 — tCK tCK tRC tRAS tRRD tRP tRCDRD tRCDWR 37 — 35 — 34 — 30 — 23 — 22 — 21 — 18 — 9 — 8 — 8 — 7 — 14 — 13 — 13 — 12 — 13 — 12 — 12 — 11 — tCCD tWTR tRTW 2 — 2 — 2 — 2 — 7 — 6 — 6 — 5 — 3) Command and Address Setup and Hold Timing Address/Command input setup time Address/Command input hold time Address/Command input pulse width Mode Register Set Timing Mode Register Set cycle time Mode Register Set to READ timing 4)5) 3) Row Timing Row Cycle Time Row Active Time ACT(a) to ACT(b) Command period Row Precharge Time Row to Column Delay Time for Reads Row to Column Delay Time for Writes tRCDWR(Min) = max(tRCDRD(Min) - (WL + 1) × tCK;2×tCK) tCK tCK tCK tCK tCK tCK 6) 7) Column Timing CAS(a) to CAS(b) Command period Write to Read Command Delay Read to Write command delay tRTW(min)= (CL + BL/2 +2 -WL) tCK tCK tCK Write Cycle Timing Parameters for Data and Data Strobe Write command to first WDQS latching transition Rev. 0.80, 2007-09 09132007-07EM-7OYI tDQSS WL– 0.25 WL+ 0.25 33 WL– 0.25 WL+ 0.25 WL– 0.25 WL+ 0.25 WL– 0.25 WL+ 0.25 tCK 8) 9) 10) Internet Data Sheet HYB18H256321BF 256-Mbit GDDR3 Parameter CAS latency Symbol Limit Values –10 Unit Note –11 –12 –14 Min. Max. Min. Max. Min. Max. Min. Max. Data-in and Data Mask to WDQS Setup Time tDS 0.14 — 0.15 — 0.16 — 0.18 — ns Data-in and Data Mask to WDQS Hold Time tDH 0.14 — 0.15 — 0.16 — 0.18 — ns Data-in and DM input pulse width (each input) tDIPW 0.40 — 0.40 — 0.40 — 0.40 — tCK DQS input low pulse width tDQSL tDQSH tWPRE tWPST tWR 0.40 — 0.40 — 0.40 — 0.40 — 0.40 — 0.40 — 0.40 — 0.40 — 0.75 1.25 0.75 1.25 0.75 1.25 0.75 1.25 0.75 1.25 0.75 1.25 0.75 1.25 0.75 1.25 13 — 13 — 12 — 10 — tCK tCK tCK tCK tCK DQS input high pulse width DQS Write Preamble Time DQS Write Postamble Time Write Recovery Time 8) Read Cycle Timing Parameters for Data and Data Strobe tAC tRPRE Read Preamble Read Postamble tRPST Data-out high impedance time from CLK tHZ Data-out low impedance time from CLK tLZ DQS edge to Clock edge skew tDQSCK DQS edge to output data edge skew tDQSQ Data hold skew factor tQHS Data output hold time from DQS tQH Data Access Time from Clock -0.21 0.21 -0.22 0.22 -0.22 0.22 –0.25 0.25 ns 0.75 1.25 0.75 1.25 0.75 1.25 0.75 1.25 0.75 1.25 0.75 1.25 0.75 1.25 0.75 1.25 tCK tCK tACmin tACmax tACmin tACmax tACmin tACmax tACmin tACmax ns tACmin tACmax tACmin tACmax tACmin tACmax tACmin tACmax ns -0.21 0.21 -0.22 0.22 -0.22 0.22 –0.25 0.25 ns — 0.120 — 0.130 — 0.140 — 0.160 ns — 0.120 — 0.130 — 0.140 — 0.160 ns tHP–tQHS ns Refresh/Power Down Timing Refresh Period (8192 cycles) Average periodic Auto Refresh interval Delay from AREF to next ACT/ AREF tREF tREFI tRFC tXSC tXPN — tATS tATH tKO tRIDon tRIDoff 32 3.9 32 3.9 52.0 32 3.9 — 52.0 — 32 ms μs 3.9 — 52.0 — ns 1000 — 1000 — 1000 — 7 — 7 — 7 — 6 — tCK tCK 10 — 10 — 10 — 10 — ns 10 — 10 — 10 — 10 — ns 10 — 10 — 10 — 10 — ns — 20 — 20 — 20 — 20 ns Rev. ID EMRS to DQ off timing — 20 — 20 — 20 DLL on mode ( -10/-11/-12/-14 fCK(Min )= 400 MHz) DLL on mode ( -10/-11/-12/-14 fCK(Min )= 400 MHz) tHP is the lesser of tCL minimum and tCH minimum actually applied to the device CLK, CLK inputs — 20 ns Power Down Exit time — — 1000 — Self Refresh Exit time 52.0 — Other Timing Parameters RES to CKE setup timing RES to CKE hold timing Termination update Keep Out timing Rev. ID EMRS to DQ on timing 1) 2) 3) 4) 5) 6) 7) This value of tMRD applies only to the case where the “DLL reset” bit is not activated tMRD is defined from MRS to any other command then READ tRASmax is 8*tREF tRCDWR(Min) may not drop below 2 × tCK Rev. 0.80, 2007-09 09132007-07EM-7OYI 34 11) Internet Data Sheet HYB18H256321BF 256-Mbit GDDR3 8) 9) 10) 11) tCCD is either for gapless consecutive reads or gapless consecutive writes. BL =4 WTR and tWR start at the first rising edge of CLK after the last valid (falling) WDQS edge of the slowest WDQS signal Please round up tRTW to the next integer of tCK This parameter is defined per byte Rev. 0.80, 2007-09 09132007-07EM-7OYI 35 Internet Data Sheet HYB18H256321BF 256-Mbit GDDR3 5 Package 5.1 Package Outline FIGURE 18 Package Outline PG-TFBGA-136-060 -!8 X " ! -!8 X -!8 # -!8 -). # X - # ! " - # # 3%!4).' 0,!.% ,EAD FREE SOLDER BALLS GREEN SOLDER BALLS "AD UNIT MARKING "5- LIGHT GOOD -IDDLE OF PACKAGES EDGES 0ACKAGE ORIENTATION MARK ! 3"!FIDUCIAL SOLDER BALL ATTACH /PENING IN SOLDER RESIST &0/?0'4&"'!?? Note: The package is conforming with JEDEC MO-207i, VAR DR-z. Rev. 0.80, 2007-09 09132007-07EM-7OYI 36 Internet Data Sheet HYB18H256321BF 256-Mbit GDDR3 5.2 Package Thermal Characteristics TABLE 20 PG-TFBGA-136 Package Thermal Resistances Theta_jA Theta_jB Theta_jC JEDEC Board 1s0p 2s0p Air Flow 0 m/s 1 m/s 3 m/s 0 m/s 1 m/s 3 m/s - - K/W 40 32 27 22 19 17 5 2 Notes 1. Theta_jA: Junction to Ambient thermal resistance. The values have been obtained by simulation using the conditions stated in the JEDEC JESD-51 standard. 2. Theta_jB: Junction to Board thermal resistance. The value has been obtained by simulation. 3. Theta_jC: Junction to Case thermal resistance. The value has been obtained by simulation. Rev. 0.80, 2007-09 09132007-07EM-7OYI 37 Internet Data Sheet HYB18H256321BF 256-Mbit GDDR3 List of Illustrations Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 Figure 10 Figure 11 Figure 12 Figure 13 Figure 14 Figure 15 Figure 16 Figure 17 Figure 18 Ballout 256-Mbit GDDR3 Graphics RAM [Top View, MF = Low ] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Mode Register Set Command. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Mode Register Bitmap for Mid-Range-Speed Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Mode Register Bitmap for High-Speed Application. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Mode Register Set Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Extended Mode Register Set Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Extended Mode Register Bitmap for Mid-Range-Speed Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Extended Mode Register Bitmap for High-Speed Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Extended Mode Register Set Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Timing of Vendor Code and Revision ID Generation on DQ[7:0] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Extended Mode Register 2 Set Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Extended Mode Register 2 Bitmap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Output Test Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 40 Ohm Driver Pull-Down and Pull-Up Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 60 Ohm Active Termination Characteristic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 120 Ohm Active Termination Characteristic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 240 Ohm Active Termination Characteristic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Package Outline PG-TFBGA-136-060 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Rev. 0.80, 2007-09 09132007-07EM-7OYI 38 Internet Data Sheet HYB18H256321BF 256-Mbit GDDR3 List of Tables Table 1 Table 2 Table 3 Table 4 Table 5 Table 6 Table 7 Table 8 Table 9 Table 10 Table 11 Table 12 Table 13 Table 14 Table 15 Table 16 Table 17 Table 18 Table 19 Table 20 Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Ball Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Ball Assignment with Mirror . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Function Truth Table I. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Function Truth Table II (CKE Table) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Burst Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 ON/OFF mode of DQ/DM receivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Revision ID and Vendor Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Power & DC Operation Conditions (0 °C ≤ Tc ≤ 85 °C). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 DC & AC Logic Input Levels (0 °C ≤ Tc ≤ 85 °C). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Differential Clock DC and AC Input conditions (0 °C ≤ Tc ≤ 85 °C). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Pin Capacitances (VDDQ = 1.8 V, TA = 25°C, f = 1 MHz) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Programmed Driver IV Characteristics at 40 Ohm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Programmed Terminator Characteristics at 60 Ohm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Programmed Terminator Characteristics of 120 Ohm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Programmed Terminator Characteristics at 240 Ohm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Operating Current Measurement Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Timing Parameters for HYB18H256321BF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 PG-TFBGA-136 Package Thermal Resistances. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Rev. 0.80, 2007-09 09132007-07EM-7OYI 39 Internet Data Sheet HYB18H256321BF 256-Mbit GDDR3 Contents 1 1.1 1.2 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2 2.1 2.2 2.3 2.3.1 2.4 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Ball Definition and Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Mirror Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Truth Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Function Truth Table for more than one Activated Bank. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Function Truth Table for CKE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 3 3.1 3.1.1 3.1.2 3.1.3 3.1.4 3.1.5 3.1.6 3.2 3.2.1 3.2.2 3.2.3 3.2.4 3.2.5 3.3 3.3.1 Functional Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mode Register Set Command (MRS). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Burst length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Burst type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CAS Latency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Write Latency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Test mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DLL Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Extended Mode Register Set Command (EMRS1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DLL enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . WR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Termination Rtt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Output Driver Impedance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Vendor Code and Revision Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Extended Mode Register 2 Set Command (EMRS2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . App Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 11 14 14 14 14 15 15 16 19 19 19 19 19 21 22 4 4.1 4.2 4.2.1 4.3 4.4 4.5 4.6 4.7 4.7.1 4.7.2 4.8 4.9 4.10 4.11 Electrical Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Absolute Maximum Ratings and Operation Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DC Operation Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Recommended Power & DC Operation Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DC & AC Logic Input Levels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Differential Clock DC and AC Levels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Output Test Conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pin Capacitances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Driver current characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Driver IV characteristics at 40 Ohms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Termination IV Characteristic at 60 Ohms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Termination IV Characteristic at 120 Ohms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Termination IV Characteristic at 240 Ohms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operating Current Measurement Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AC Timings for HYB18H256321BF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 23 23 23 24 25 25 26 26 26 27 29 30 31 33 5 5.1 5.2 Package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Package Outline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Package Thermal Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Rev. 0.80, 2007-09 09132007-07EM-7OYI 40 Internet Data Sheet Edition 2007-09 Published by Qimonda AG Gustav-Heinemann-Ring 212 D-81739 München, Germany © Qimonda AG 2007. All Rights Reserved. Legal Disclaimer The information given in this Internet Data Sheet shall in no event be regarded as a guarantee of conditions or characteristics (“Beschaffenheitsgarantie”). With respect to any examples or hints given herein, any typical values stated herein and/or any information regarding the application of the device, Qimonda hereby disclaims any and all warranties and liabilities of any kind, including without limitation warranties of non-infringement of intellectual property rights of any third party. Information For further information on technology, delivery terms and conditions and prices please contact your nearest Qimonda Office. Warnings Due to technical requirements components may contain dangerous substances. For information on the types in question please contact your nearest Qimonda Office. Qimonda Components may only be used in life-support devices or systems with the express written approval of Qimonda, if a failure of such components can reasonably be expected to cause the failure of that life-support device or system, or to affect the safety or effectiveness of that device or system. Life support devices or systems are intended to be implanted in the human body, or to support and/or maintain and sustain and/or protect human life. If they fail, it is reasonable to assume that the health of the user or other persons may be endangered. www.qimonda.com