SEMIKRON SKS360FB6C240V16

SKS 360F B6C 240 V16
Characteristics
Symbol
Conditions
min.
typ.
max.
Unit
360
A
258
388
A
217
435
A
1200
V
Electrical Data
Id
Tamb=35°C
no overload
150 % overload,
60s every 10 min.
200 % overload,
60s every 10 min.
VCES
SEMISTACK Thyristor
Three-phase controlled
bridge rectifier
SKS 360F B6C 240 V16
Preliminary Data
VDC
DC voltage applied to the capacitor
bank
510
V
VAC
network voltage (line side), -20% /
+15%
380
V
Visol
50 Hz / 1 min.
2
it
(di/dt)cr
2500
V
Tvj = 25°C
145
kA2s
Tvj = 125°C
125
kA2s
200
A/µs
1000
V/µs
Tvj = 125°C
(dv/dt)cr
VGT
2
V
Features
IGT
150
mA
• P16/200F heatsink
• Isolated base modules
• Forced air cooled
Ptot
Tamb = 35°C
1015
W
Rthja
per component
0.53
K/W
Typical Applications
Fuse
No fuse
•
•
•
•
RC
Resistance
RC
Capacitance
Thermal
trip
normally closed
Industrial rectifiers
Softstarters
AC control
DC motor control
Options
Tvj
- 40
125
°C
-
A
33
Ω
0.47
µF
75
°C
Mechanical Data
No. 08767220
dv/dtAIR
required airflow per fan
w
approx. total weight
Size
Width x Depth x Height (with fan)
m3/h
kg
148
mm
Tstg
5
60
°C
Tamb
5
60
°C
1000
m
Altitude
431
Installation height w/o derating
Protection
Pollution
248
IP00
EN 50178
2
Fan Data
Fan
included in the stack (YES )
Type
SKF 16A-230-01
VFan
Fan voltage
230
V
fFAN
Fan frequency
50
Hz
IFAN
Fan current
0,6
A
PFAN
Fan power
135
W
B6C
© by SEMIKRON
Rev. 6 – 18.11.2008
1
SKS 360F B6C 240 V16
Fig. 1 Maximal overload factor vs nom current and ovl
duration, Tamb = 35°C
Fig. 2 Maximal overload factor vs nom current and ovl
duration, Tamb = 45°C
Fig. 3 Maximal overload duration vs nom current and ovl
factor, Tamb = 35°C
Fig. 4 Maximal overload duration vs nom current and ovl
factor, Tamb = 45°C
Fig.5 Power losses
Fig. 6 Thermal impedance Zth(j-a)
2
Rev. 6 – 18.11.2008
© by SEMIKRON
SKS 360F B6C 240 V16
Note: Stack design may vary depending upon the version. Please contact SEMIKRON for further details.
This technical information specifies semiconductor devices but promises no characteristics. No warranty or guarantee expressed or
implied is made regarding delivery, performance or suitability.
© by SEMIKRON
Rev. 6 – 18.11.2008
3