OC-3 IR1 SFP Transceiver SP-03-IR1 Features • Compliant with OC-3/STM-1 Standards • Digital Diagnostic SFF-8472 Compliant • Single 3.3V Supply • 19dB Minimum Link Budget • Commercial and Industrial Temperature Available • 1310nm FP Laser • SFP MSA SFF-8074i Compliant • Compliant with GR-253 OC-3, IR1 and SR1 • Telcordia GR-468 Compliant • Color coded bail latch : Grey • RoHS compliant General Operation Parameter Supply Voltage Total Current Symbol Min. Typical Max. Unit Vcc 3.135 3.3 3.465 V Icc - - 300 mA Power Supply Noise Rejectiona PSR 100 - - mVp-p Operating Case Temperature (-Cxx) Topr -5 - 70 ºC Operating Case Temperature (-Txx) Top -40 - 85 ºC Storage Temperature Tst -40 - 85 ºC Data Rate OC-3/STM-1 DR - 155 - Mbps a) 20Hz to 155MHz Transmitter Specifications (Optical) Parameter Symbol Min Typical Max Unit Optical Power Pop -15 -11 -8 dBm Average Launch Power (Tx:Off) Poff - - -45 dBm Extinction Ratio ER 8.2 - - dB - - - SONET/SDH compliant - 2 ns Eye Mask Optical Rise Timeb tr - Optical Fall Timeb tf - Mean Wavelength λ 1261 Δλ - Spectral Width (RMS) 2 ns 1310 1360 nm - 7.7 nm b) 20%-80% values LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 1 LUMNDS916-Sep1107 Rev A.2 OC-3 IR1 SFP Transceiver SP-03-IR1 Transmitter Specifications (Electrical) Parameter Symbol Min Typical Max Unit Rin 80 100 120 Ω PECL Single-Ended Data Input Swing Vin,p-p 250 - 1200 mV TxFault_Fault Vfault 2 - Vcc V Vnormal Vee - Vee+0.5 V Vd 2 - Vcc V Ven Vee - Vee+0.8 V Parameter Symbol Min Typical Max Unit Receive Power Lowc Rsens,low - -36 -34 dBm c Receive Power High Rsens,high -8 - - dBm Receiver Damage Power Pin,damage 0 - - dBm λ 1260 1310 1360 nm LOS Assert LOS_A -44 - - dBm LOS De-Assert LOS_D - - -34 dBm LOS Hysteresis Hys 0.5 - - dB Parameter Symbol Min Typical Max Unit PECL Single-Ended Data Output Swing Vout, p-p 185 - 800 mV Data Output Rise Time tr - - 2 ns Data Output Fall Time tf - - 2 ns Symbol Min Typical Max Unit t_on - - 1 ms Tx Disable Assert Time t_off - - 10 µs Time To Initialize, Including Reset Of Tx Fault t_init - - 300 ms t_fault - - 100 µs Input Differential Impedence TxFault_Normal TxDisable_Disable TxDisable_Enable Receiver Specifications (Optical) Wavelengthd 23 10-10 c) 2 -1 PRBS, BER d) Operational over 1200 to 1625nm range Receiver Specifications (Electrical) Timing and Electrical Parameter Tx Disable Negate Time Tx Fault Assert Time Tx Disable To Reset t_reset 10 - - µs LOS Assert Time t_loss_on - - 100 µs LOS De-Assert Time t_loss_off - - 100 µs Serial ID Clock Rate f_serial_clock RX_LOS Voltage (High) RX_LOS Voltage (Low) LOS Output Voltage-Fault LOS Output Voltage-Normal - - 100 KHz 2 - - V - - 0.8 V VLOS fault 2 - Vcc V VLOSnormal Vee - Vee+0.5 V MOD_DEF (0:2)-High Vh 2 - Vcc V MOD_DEF (0:2)-LOW Vl Vee - Vee+0.5 V LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 2 LUMNDS916-Sep1107 Rev A.2 OC-3 IR1 SFP Transceiver SP-03-IR1 Diagnostics Range Accuracy Unit Calibration Temperature (-CDA) -5 to 70 ±3 ºC External Temperature (-TDA) -40 to 85 ±3 ºC External Tc(C) = Tslope*Tad(16 bit signed twos complement value) + Toffset Voltage 0 to Vcc 0.1 V External V(Volts) = Vslope*Vad (16 bit unsigned integer) + Voffset Bias current 0 to 120 5 mA External I(mA)=Islope*Iad(16 bit unsigned integer)+Ioffset TX Power -15 to -8 ±3 dBm External TX_PWR(µW)=TX_PWRslope*TX_PWRad(16 bit unsigned integer +TX_PWRoffset RX Power -34 to -8 ±3 dBm External RX_PWR(µW)=A0+A1*x+A2*x^2+A3*x^3+A4*x^4 Parameter Formula Tc(C) = Tslope*Tad(16 bit signed twos complement value) + Toffset EEPROM Serial ID Name of Field Vendor Name Vendor OUI Vendor P/N LUMINENTOIC.COM Description of Field SFP Vendor name(ASCII) IEEE vendor OUI code for LuminentOIC Inc. Part number in ASCII, e.g. SP-03-IR1-CDA Address Hex 20 4C L 21 55 U 22 4D M 23 49 I 24 4E N 25 45 E 26 4E N 27 54 T 28 4F O 29 49 I 30 43 C 37 00 38 06 39 B5 40 53 41 50 P 42 30 0 43 33 3 44 49 I 45 52 R 46 31 1 47 43 C 48 44 D 49 41 A 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 3 ASCII S LUMNDS916-Sep1107 Rev A.2 OC-3 IR1 SFP Transceiver SP-03-IR1 Pin Function Notes 1 VeeT Tx Ground 2 TX_FAULT Open Collector 3 TX_DISABLE Internally Pulled High 4 MOD_DEF2 Serial Data Input 5 MOD_DEF1 Serial Clock Input MOD_DEF0 Internally Grounded 7 NC Not Connected 8 LOS Open Collector 9 VeeR RX Ground 10 VeeR RX Ground 11 VeeR RX Ground 12 RXD- RX Data Negative 13 RXD+ RX Data Positive 14 VeeR RX GND 15 VccR RX Power 16 VccT TX Power 17 VeeT TX GND 18 TXD+ TX Data Positive 19 TXD- TX Data Negative 20 VeeT TX GND 6 LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 4 LUMNDS916-Sep1107 Rev A.2 OC-3 IR1 SFP Transceiver SP-03-IR1 Outline Drawing Units in mm(inch) LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 5 LUMNDS916-Sep1107 Rev A.2 OC-3 IR1 SFP Transceiver SP-03-IR1 Suggested Transceiver interface 1�H Vcc 10�F 1�H 0.1�F VCCT .01�F Protocol IC R1 LuminentOIC SFP 10K� TX_DISABLE TX_DISABLE TX_FAULT TX_FAULT TD + SerDes Laser Driver .01�F 100� TD VEET .01�F VCCR 10�F 0.1�F RD + Receiver Amplifier .01�F 100� RD - RX_LOS RX_LOS Vcc R VEER 1 R1 R1 .01�F EEPROM R1 MOD_DEF 2 MOD_DEF 1 MOD_DEF 0 R1=4.7K to 10K� LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 6 LUMNDS916-Sep1107 Rev A.2 OC-3 IR1 SFP Transceiver SP-03-IR1 Ordering Information Availabe Options: SP-03-IR1-CDA SP-03-IR1-TDA SP-03-IR1-CNA SP-03-IR1-TNA Part Numbering Definitions: S P - 0 3 - I R 1 - Temperature Diagnostic Revision - Customer Specific • SP = SFP Form Factor 03 = 155Mbps IR1 = Reach 15 Km • Operating Temperature C = Commercial temperature (-5 to 70ºC) T= Industrial temperature (-40 to 85ºC) • D = Digital Diagnostic N = No Digital Diagnostic • Ordering Information A = RoHS compliant • Blank = Standard Procedure Labelling, Serial number, or Shipping Instructions, etc. Warnings: Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow guidelines according to proper ESD procedures. Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation. Legal Notes: IMPORTANT NOTICE! All information contained in this document is subject to change without notice, at LuminentOIC’s sole and absolute discretion. LuminentOIC warrants performance of its products to current specifications only in accordance with the company’s standard one-year warranty; however, specifications designated as “preliminary” are given to describe components only, and LuminentOIC expressly disclaims any and all warranties for said products, including express, implied, and statutory warranties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the company’s Terms and Conditions of Sale for further warranty information. LuminentOIC assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and LuminentOIC makes no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this document are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. LuminentOIC customers using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify LuminentOIC for any damages resulting from such use or sale. THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN “AS IS” BASIS. Customer agrees that LuminentOIC is not liable for any actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact LuminentOIC to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current. © LuminentOIC, Inc. 2003 All rights reserved LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 7 LUMNDS916-Sep1107 Rev A.2