SOURCE SP-03-IR1-TDA

OC-3 IR1 SFP Transceiver
SP-03-IR1
Features
• Compliant with OC-3/STM-1 Standards
• Digital Diagnostic SFF-8472 Compliant
• Single 3.3V Supply
• 19dB Minimum Link Budget
• Commercial and Industrial Temperature Available
• 1310nm FP Laser
• SFP MSA SFF-8074i Compliant
• Compliant with GR-253 OC-3, IR1 and SR1
• Telcordia GR-468 Compliant
• Color coded bail latch : Grey
• RoHS compliant
General Operation
Parameter
Supply Voltage
Total Current
Symbol
Min.
Typical
Max.
Unit
Vcc
3.135
3.3
3.465
V
Icc
-
-
300
mA
Power Supply Noise Rejectiona
PSR
100
-
-
mVp-p
Operating Case Temperature (-Cxx)
Topr
-5
-
70
ºC
Operating Case Temperature (-Txx)
Top
-40
-
85
ºC
Storage Temperature
Tst
-40
-
85
ºC
Data Rate OC-3/STM-1
DR
-
155
-
Mbps
a) 20Hz to 155MHz
Transmitter Specifications (Optical)
Parameter
Symbol
Min
Typical
Max
Unit
Optical Power
Pop
-15
-11
-8
dBm
Average Launch Power (Tx:Off)
Poff
-
-
-45
dBm
Extinction Ratio
ER
8.2
-
-
dB
-
-
-
SONET/SDH compliant
-
2
ns
Eye Mask
Optical Rise Timeb
tr
-
Optical Fall Timeb
tf
-
Mean Wavelength
λ
1261
Δλ
-
Spectral Width (RMS)
2
ns
1310
1360
nm
-
7.7
nm
b) 20%-80% values
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
1
LUMNDS916-Sep1107
Rev A.2
OC-3 IR1 SFP Transceiver
SP-03-IR1
Transmitter Specifications (Electrical)
Parameter
Symbol
Min
Typical
Max
Unit
Rin
80
100
120
Ω
PECL Single-Ended Data Input Swing
Vin,p-p
250
-
1200
mV
TxFault_Fault
Vfault
2
-
Vcc
V
Vnormal
Vee
-
Vee+0.5
V
Vd
2
-
Vcc
V
Ven
Vee
-
Vee+0.8
V
Parameter
Symbol
Min
Typical
Max
Unit
Receive Power Lowc
Rsens,low
-
-36
-34
dBm
c
Receive Power High
Rsens,high
-8
-
-
dBm
Receiver Damage Power
Pin,damage
0
-
-
dBm
λ
1260
1310
1360
nm
LOS Assert
LOS_A
-44
-
-
dBm
LOS De-Assert
LOS_D
-
-
-34
dBm
LOS Hysteresis
Hys
0.5
-
-
dB
Parameter
Symbol
Min
Typical
Max
Unit
PECL Single-Ended Data Output Swing
Vout, p-p
185
-
800
mV
Data Output Rise Time
tr
-
-
2
ns
Data Output Fall Time
tf
-
-
2
ns
Symbol
Min
Typical
Max
Unit
t_on
-
-
1
ms
Tx Disable Assert Time
t_off
-
-
10
µs
Time To Initialize, Including Reset Of Tx Fault
t_init
-
-
300
ms
t_fault
-
-
100
µs
Input Differential Impedence
TxFault_Normal
TxDisable_Disable
TxDisable_Enable
Receiver Specifications (Optical)
Wavelengthd
23
10-10
c) 2 -1 PRBS, BER
d) Operational over 1200 to 1625nm range
Receiver Specifications (Electrical)
Timing and Electrical
Parameter
Tx Disable Negate Time
Tx Fault Assert Time
Tx Disable To Reset
t_reset
10
-
-
µs
LOS Assert Time
t_loss_on
-
-
100
µs
LOS De-Assert Time
t_loss_off
-
-
100
µs
Serial ID Clock Rate
f_serial_clock
RX_LOS Voltage (High)
RX_LOS Voltage (Low)
LOS Output Voltage-Fault
LOS Output Voltage-Normal
-
-
100
KHz
2
-
-
V
-
-
0.8
V
VLOS fault
2
-
Vcc
V
VLOSnormal
Vee
-
Vee+0.5
V
MOD_DEF (0:2)-High
Vh
2
-
Vcc
V
MOD_DEF (0:2)-LOW
Vl
Vee
-
Vee+0.5
V
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
2
LUMNDS916-Sep1107
Rev A.2
OC-3 IR1 SFP Transceiver
SP-03-IR1
Diagnostics
Range
Accuracy
Unit
Calibration
Temperature (-CDA)
-5 to 70
±3
ºC
External
Temperature (-TDA)
-40 to 85
±3
ºC
External
Tc(C) = Tslope*Tad(16 bit signed twos complement value) + Toffset
Voltage
0 to Vcc
0.1
V
External
V(Volts) = Vslope*Vad (16 bit unsigned integer) + Voffset
Bias current
0 to 120
5
mA
External
I(mA)=Islope*Iad(16 bit unsigned integer)+Ioffset
TX Power
-15 to -8
±3
dBm
External
TX_PWR(µW)=TX_PWRslope*TX_PWRad(16 bit unsigned integer
+TX_PWRoffset
RX Power
-34 to -8
±3
dBm
External
RX_PWR(µW)=A0+A1*x+A2*x^2+A3*x^3+A4*x^4
Parameter
Formula
Tc(C) = Tslope*Tad(16 bit signed twos complement value) + Toffset
EEPROM Serial ID
Name of Field
Vendor Name
Vendor OUI
Vendor P/N
LUMINENTOIC.COM
Description of Field
SFP Vendor name(ASCII)
IEEE vendor OUI code for LuminentOIC Inc.
Part number in ASCII, e.g.
SP-03-IR1-CDA
Address
Hex
20
4C
L
21
55
U
22
4D
M
23
49
I
24
4E
N
25
45
E
26
4E
N
27
54
T
28
4F
O
29
49
I
30
43
C
37
00
38
06
39
B5
40
53
41
50
P
42
30
0
43
33
3
44
49
I
45
52
R
46
31
1
47
43
C
48
44
D
49
41
A
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
3
ASCII
S
LUMNDS916-Sep1107
Rev A.2
OC-3 IR1 SFP Transceiver
SP-03-IR1
Pin
Function
Notes
1
VeeT
Tx Ground
2
TX_FAULT
Open Collector
3
TX_DISABLE
Internally Pulled High
4
MOD_DEF2
Serial Data Input
5
MOD_DEF1
Serial Clock Input
MOD_DEF0
Internally Grounded
7
NC
Not Connected
8
LOS
Open Collector
9
VeeR
RX Ground
10
VeeR
RX Ground
11
VeeR
RX Ground
12
RXD-
RX Data Negative
13
RXD+
RX Data Positive
14
VeeR
RX GND
15
VccR
RX Power
16
VccT
TX Power
17
VeeT
TX GND
18
TXD+
TX Data Positive
19
TXD-
TX Data Negative
20
VeeT
TX GND
6
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
4
LUMNDS916-Sep1107
Rev A.2
OC-3 IR1 SFP Transceiver
SP-03-IR1
Outline Drawing
Units in mm(inch)
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
5
LUMNDS916-Sep1107
Rev A.2
OC-3 IR1 SFP Transceiver
SP-03-IR1
Suggested Transceiver interface
1�H
Vcc
10�F
1�H
0.1�F
VCCT
.01�F
Protocol IC
R1
LuminentOIC
SFP
10K�
TX_DISABLE
TX_DISABLE
TX_FAULT
TX_FAULT
TD +
SerDes
Laser Driver
.01�F
100�
TD VEET
.01�F
VCCR
10�F
0.1�F
RD +
Receiver Amplifier
.01�F
100�
RD -
RX_LOS
RX_LOS
Vcc
R
VEER
1
R1
R1
.01�F
EEPROM
R1
MOD_DEF 2
MOD_DEF 1
MOD_DEF 0
R1=4.7K to 10K�
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
6
LUMNDS916-Sep1107
Rev A.2
OC-3 IR1 SFP Transceiver
SP-03-IR1
Ordering Information
Availabe Options:
SP-03-IR1-CDA
SP-03-IR1-TDA
SP-03-IR1-CNA
SP-03-IR1-TNA
Part Numbering Definitions:
S P - 0 3 - I R 1 - Temperature
Diagnostic
Revision - Customer Specific
• SP = SFP Form Factor
03 = 155Mbps
IR1 = Reach 15 Km
• Operating Temperature
C = Commercial temperature (-5 to 70ºC)
T= Industrial temperature (-40 to 85ºC)
• D = Digital Diagnostic
N = No Digital Diagnostic
• Ordering Information
A = RoHS compliant
• Blank = Standard Procedure
Labelling, Serial number, or Shipping Instructions, etc.
Warnings:
Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow
guidelines according to proper ESD procedures.
Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation.
Legal Notes:
IMPORTANT NOTICE!
All information contained in this document is subject to change without notice, at LuminentOIC’s sole and absolute discretion. LuminentOIC warrants performance
of its products to current specifications only in accordance with the company’s standard one-year warranty; however, specifications designated as “preliminary” are
given to describe components only, and LuminentOIC expressly disclaims any and all warranties for said products, including express, implied, and statutory warranties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the company’s Terms and Conditions of
Sale for further warranty information.
LuminentOIC assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual
property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and LuminentOIC makes
no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this document are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. LuminentOIC customers
using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify LuminentOIC for any damages resulting from
such use or sale.
THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN “AS IS” BASIS. Customer agrees that LuminentOIC is not liable for any
actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact
LuminentOIC to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current.
© LuminentOIC, Inc. 2003
All rights reserved
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
7
LUMNDS916-Sep1107