SFP Bi-Directional Transceiver SPL-54-GB-BZ Features • Compliant with IEEE 802.3ah • Simplex LC Connector • Digital Diagnostic SFF-8472 Compliant • SFP MSA SFF-8074i Compliant • 24dB Minimum Power Budget • 80km Minimum Reach • Commercial Temperature Operation • Single 3.3V Supply • 1570nm DFB Laser • Telcordia GR-468 Compliant • Color Coded Bail Latch: Orange • RoHS compliant General Operation Parameter Symbol Min. Typ. Max. Supply Voltage Vcc 3.135 3.3 3.465 V Total Current ICC - - 300 mA Power Supply Noise Rejection Unit 100 - - mVp-p Operating Temperature (Case) Topr -5 - 70 ºC Storage Temperature Tstg -40 - 85 ºC Data Rate DR - 1250 - Mbps Transmitter Specifications (Optical) Parameter Symbol Min Typical Max Unit Optical Power Pop -2 - +3 dBm Optical Crosstalk XT - -45 -40 dB Average Launch Power Tx_Off Poff - - -45 dBm Extinction Ratio ER 9 - - dB Eye Mask IEEE 802.3ah Compliant Optical Rise Time (20% to 80% Values) tr - - 260 ps Optical Fall Time (20% to 80% Values) tf - - 260 ps λ 1555 1570 1610 nm Spectral Width (RMS, -20dB) ∆λ - - 1 nm Side Mode Suppression Ratio SMSR 30 - - dB Relative Intensity Noise RIN - - -120 dB/Hz Transmitter Reflectance - - - -12 dB ORLT - - 12 dB Mean Wavelength Optical Return Loss Tolerance LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 1 LUMNDS495-Jun0208 Rev A.1 SFP Bi-Directional Transceiver SPL-54-GB-BZ Transmitter Specifications (Electrical) Parameter Symbol Min Typical Max Unit Rin 80 100 120 Ω Vin, p-p 250 - 1200 mV Vfault 2 - Vcc V Vnormal Vd Vee - Vee + 0.5 V TxDisable_Disable 2 - Vcc V TxDisable_Enable Ven Vee - Vee + 0.8 V Parameter Symbol Min Typical Max Unit Receiver Power Lowa - -28 -26 dBm Receiver Power Higha Rsens,low Rsens,high -3 - - dBm Damage Threshold for Receiver Pin, damage 6 - - dBm Wavelength λ 1470 - 1510 nm LOS Assert - -45 - - dBm LOS De-Assert - - - -24 dBm LOS Hysteresis - 0.5 - - dB Receiver Reflectance - - - -12 dB Parameter Symbol Min Typical Max Unit PECL Single Ended Data Output Swing Vout,p-p 185 - 800 mV Data Output Rise Time tr - - 175 ps Data Output Fall Time tf - - 175 ps Input Differential Impedence PECL Single Ended Data Input Swing TxFault_Fault TxFault_Normal Receiver Specifications (Optical) a) Measured at 10-12 BER, PRBS 27-1, 9dB ER Receiver Specifications (Electrical) Timing and Electrical Parameter Symbol Min Typical Max Unit t_on - - 1 ms Tx Disable Assert Time t_off - - 10 µs Time to Initialize, Including Reset of Tx Fault t_init - - 300 ms t_fault - - 100 µs Tx Disable Negate Time Tx Fault Assert Time Tx Disable to Reset LOS Assert Time LOS De-Assert Time Serial ID Clock Rate RX_LOS Voltage (High) t_reset 10 - - µs t_loss_on - - 100 µs t_loss_off f_serial_clock Rx_LOSH 2 - 100 100 Vcc µs KHz V RX_LOS Voltage (Low) RX_LOSL - - 0.8 V LOS Output Voltage-Fault VLOS fault 2 - Vcc V VLOS normal Vee - Vee + 0.5 V MOD_DEF (0:2)-High Vh 2 - V MOD_DEF (0:2)-Low VI Vee - Vcc Vee + 0.5 LOS Output Voltage-Normal LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 2 V LUMNDS495-Jun0208 Rev A.1 SFP Bi-Directional Transceiver SPL-54-GB-BZ Diagnostics Parameter Range Accuracy Unit Temperature (CDA) -5 to 70 ±3 ºC Calibration Bit Value External 1/256 C Formula Voltage 0 to Vcc 0.1 V External 100µV Bias Current 0 to 120 5 mA External - I(mA) = Islope * Iad(16 bit unsigned integer)+Ioffset Tc(C) = Tslope*Tad(16 bit signed twos complement value) + Toffset V(Volts) = Vslope*Vad (16 bit unsigned integer) + Voffset Tx Power -2 to +3 ±3 dBm External - Tx_PWR(µW) = Tx_PWRslope*Tx_PWRad(16 bit unsigned integer)+Tx_PWRoffset Rx Power -26 to -3 ±3 dBm External - Rx_PWR(µW) = A0+A1*x+A2*x^2+A3*x^3+A4*x^4 EEPROM Serial ID Name of Field Vendor Name Vendor OUI Vendor P/N LUMINENTOIC.COM Description of Field SFPVendor name (ASCII) IEEE vendor OUI code for Luminent Inc. Part number in ASCII, e.g. SPL-54-GB-BZ-CDA Address Hex 20 4C L 21 55 U 22 4D M 23 49 I 24 4E N 25 45 E 26 4E N 27 54 T 28 4F O 29 49 I 30 43 C 37 00 38 06 39 B5 40 53 S 41 50 P 42 4C L 43 35 5 44 34 4 45 47 G 46 42 B 47 42 B 48 5A Z 49 43 C 50 44 D 51 41 A 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 3 ASCII LUMNDS495-Jun0208 Rev A.1 SFP Bi-Directional Transceiver SPL-54-GB-BZ Pinout Definitions Pin Function Notes 1 VeeT TX GND 2 TX_FAULT Open Collector 3 TX_DISABLE Internally Pulled High 4 MOD_DEF2 Serial Data Input 5 MOD_DEF1 Serial Clock Input 6 MOD_DEF0 Internally Grounded 7 NC Not Connected 8 LOS Open Collector 9 VeeR RX Ground 10 VeeR RX Ground 11 VeeR RX Ground 12 RXD- RX Data Negative 13 RXD+ RX Data Positive 14 VeeR RX GND 15 VCCR RX Power 16 VCCT TX Power 17 VeeT TX GND 18 TXD+ TX Data Positive 19 TXD- TX Data Negative 20 VeeT TX GND LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 4 LUMNDS495-Jun0208 Rev A.1 SFP Bi-Directional Transceiver SPL-54-GB-BZ LC Connector Mechanicals Units in mm (inches) LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 5 LUMNDS495-Jun0208 Rev A.1 SFP Bi-Directional Transceiver SPL-54-GB-BZ Suggested Transceiver Interface Diagnostics 1�H Vcc 10�F 1�H 0.1�F VCCT .01�F Protocol IC R1 LuminentOIC SFP 10K� TX_DISABLE TX_DISABLE TX_FAULT TX_FAULT TD + SerDes Laser Driver .01�F 100� TD VEET .01�F VCCR 10�F 0.1�F RD + Receiver Amplifier .01�F 100� RD - RX_LOS RX_LOS Vcc R VEER 1 R1 R1 .01�F EEPROM R1 MOD_DEF 2 MOD_DEF 1 MOD_DEF 0 R1=4.7K to 10K� LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 6 LUMNDS495-Jun0208 Rev A.1 SFP Bi-Directional Transceiver SPL-54-GB-BZ Ordering Information Available Options: SPL-54-GB-BZ-CNA SPL-54-GB-BZ-CDA Part Numbering Definition: S P L - 5 4 - G B - B Z - Temperature Diagnostic Revision • SPL = LC connector • Wavelength 54 = Tx 1570nm/Rx 1490nm • Data Rate GB = GigaBit Ethernet • Reach BZ = 80km • Operating Temperature C = Commercial temperature (-5 to 70ºC) • D = Digital Diagnostic N = No Digital Diagnostic • Resivion A = RoHS compliant Warnings: Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow guidelines according to proper ESD procedures. Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation. Legal Notes: IMPORTANT NOTICE! All information contained in this document is subject to change without notice, at LuminentOIC’s sole and absolute discretion. LuminentOIC warrants performance of its products to current specifications only in accordance with the company’s standard one-year warranty; however, specifications designated as “preliminary” are given to describe components only, and LuminentOIC expressly disclaims any and all warranties for said products, including express, implied, and statutory warranties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the company’s Terms and Conditions of Sale for further warranty information. LuminentOIC assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and LuminentOIC makes no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this document are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. LuminentOIC customers using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify LuminentOIC for any damages resulting from such use or sale. THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN “AS IS” BASIS. Customer agrees that LuminentOIC is not liable for any actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact LuminentOIC to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current. © LuminentOIC, Inc. 2003 All rights reserved LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 7 LUMNDS495-Jun0208 Rev A.1