10Km Tri-rate SFP Transceiver SP-TR-LX Features • Data Rate 1.062/1.25/2.125 Gb/s • Single 3.3V Supply • 10km Reach • Fibre Channel 100-SM-LC-L Compliant • Fibre Channel 200-SM-LC-L Compliant • Gigabit Ethernet IEEE 802.3ah Compliant • 11dB Typical Link Budget • Commercial Temperature Available (-Cxx) • Commercial and Industrial Temperature Available (-Txx) • 1310nm FP Laser • SFP MSA SFF-8074i Compliant • Telcordia GR-468 Compliant • Digital Diagnostic SFF-8472 Compliant • Color Coded Bail Latch Tube: Blue • RoHS-5/6 compliant (lead exemption)(-xxA) • RoHS-6/6 compliant (lead free soldering)(-xxC) General Operation Symbol Min. Typ. Max. Supply Voltage Parameter Vcc 3.135 3.3 3.465 Unit V Total Current ICC - - 300 mA Power Supply Rejectiona PSR 100 - - mVp-p Operating Temperature (-Cxx) Topr -5 - 70 ºC Operating Temperature (-Txx) Topr -40 - 85 ºC Storage Temperature Tstg -40 - 85 ºC Data Rate GbE DR - 1250 - Mbps Data Rate 1xFC DR - 1062.5 - Mbps Data Rate 2xFC DR - 2125 - Mbps a) 20Hz to 155MHz Transmitter Specifications (Optical) Parameter Optical Power Symbol Min Typical Max Unit Pop -9 -5 -3 dBm Average Launch Power (Tx:Off) Poff - - -45 dBm Optical Modulation Amplitude OMA 0.213 - - mW ER 6 - - dB TJ - - 200 ps Optical Rise Time, GbE, 1xFC tr - - 260 ps Optical Fall Time, GbE, 1xFCb tf - - 260 ps Optical Rise Time, 2xFCb tr - - 160 ps Extinction Ratio Eye Mask IEEE 802.3ah and FC-PI Rev 13 compliant Total Jitter b b Optical Fall Time, 2xFC tf - - 160 ps λ 1265 1310 1365 nm Spectral Width (RMS)c ∆λ - - 3.5 nm Relative Intensity Noise RIN - - -120 dB/Hz Mean Wavelengthc b) 20%-80% values c) Wavelength and spectral limits complies with IEEE802.3ah and 1x/2x FC-PI Rev.13 LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 1 LUMNDS1356-Feb1607 Rev A.2 10Km Tri-rate SFP Transceiver SP-TR-LX Transmitter Specifications (Electrical) Parameter Input Differential Impedence PECL Single Ended Data Input Swing TxFault_Fault Symbol Min Typical Max Rin 80 100 120 Unit Ω Vin, p-p 250 - 1200 mV Vfault 2 - Vcc V Vee - Vee + 0.5 V TxDisable_Disable Vnormal Vd 2 - Vcc V TxDisable_Enable Ven Vee - Vee + 0.8 V Parameter Symbol Min Typical Receiver Power Lowd Rsens,low - OMA - Receiver Power High Rsens,high Damage Threshold for Receiver TxFault_Normal Receiver Specifications (Optical) Max Unit -22 -20 dBm - 0.015 mW -3 0 - dBm Pin, damage 6 - - dBm λ 1265 - 1365 nm RX_r - - -12 dB LOS Assert - -38 - - dBm LOS De-Assert - - - -20 dBm LOS Hysteresis - 0.5 - - dB d Optical Modulation Amplitude (OMA), Min d Wavelengthe Maximum Reflectance of Receiver 10-12, 27-1, d) Measured at BER of PRBS of e) Operational over 1200-1625nm range at eye center. 1.0625/1.25/2.125 Gbps Receiver Specifications (Electrical) Parameter Symbol Min Typical Max Unit PECL Single-Ended Data Output Swing Vout,p-p 185 - 800 mV tr - - 260 ps tf - - 260 ps Data Output Rise Time Data Output Fall Time Timing and Electrical Parameter Symbol Min Typical Max Unit Tx Disable Negate Time t_on - - 1 ms Tx Disable Assert Time t_off - - 10 µs Time to Initialize, Including Reset of Tx Fault t_init - - 300 ms Tx Fault Assert Time t_fault - - 100 µs Tx Disable to Reset t_reset 10 - - µs t_loss_on - - 100 µs t_loss_off f_serial_clock Rx_LOSH 2 - 100 100 Vcc µs KHz V LOS Assert Time LOS De-assert Time Serial ID Clock Rate RX_LOS Voltage (high) RX_LOS Voltage (low) RX_LOSL - - 0.8 V LOS Output Voltage-Fault VLOS fault 2 - Vcc V VLOS normal Vee - Vee + 0.5 V MOD_DEF (0:2)-High Vh 2 - V MOD_DEF (0:2)-Low VI Vee - Vcc Vee + 0.5 LOS Output Voltage-Normal LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 2 V LUMNDS1356-Feb1607 Rev A.2 10Km Tri-rate SFP Transceiver SP-TR-LX Diagnostics Parameter Range Accuracy Unit Calibration Formula Temperature (-CDx) -5 to 70 ±3 ºC Internal Tc(C) = Tad(16 bit signed twos complement)/256 Temperature (-TDx) -40 to 85 ±3 ºC Internal Tc(C) = Tad(16 bit signed twos complement)/256 Voltage 0 to Vcc 0.1 V Internal V(Volts) = Vad(16 bit unsigned integer)*0.1 Bias Current 0 to 120 5 mA External I(mA) = Islope * Iad(16 bit unsigned integer)+Ioffset Tx Power -9 to -3 ±3dB dBm External Tx_PWR(µW) = Tx_PWRslope*Tx_PWRad(16 bit unsigned integer)+Tx_PWRoffset Rx Power -20 to -3 ±3dB dBm External Rx_PWR(µW) = A0+A1*x+A2*x^2+A3*x^3+A4*x^4 EEPROM Serial ID Name of Field Vendor Name Vendor OUI Vendor P/N LUMINENTOIC.COM Discription of Field SFP Vendor name (ASCII) IEEE vendor OUI code for LuminentOIC Inc. Part number in ASCII, e.g. SP-TR-LX-CDA Address Hex ASCII 20 4C L 21 55 U 22 4D M 23 49 I 24 4E N 25 45 E 26 4E N 27 54 T 28 4F O 29 49 I 30 43 C 37 00 38 06 39 B5 40 53 S 41 50 P 42 54 T 43 52 R 44 4C L 50 58 X 51 43 C 52 44 D 53 41 A 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 3 LUMNDS1356-Feb1607 Rev A.2 10Km Tri-rate SFP Transceiver SP-TR-LX Pinout Definitions Pin Function Notes 1 VeeT TX GND 2 TX_FAULT Open Collector 3 TX_DISABLE Internally Pulled High 4 MOD_DEF2 Serial Data Input 5 MOD_DEF1 Serial Clock Input 6 MOD_DEF0 Internally Grounded 7 NC Not Connected 8 LOS Open Collector 9 VeeR RX Ground 10 VeeR RX Ground 11 VeeR RX Ground 12 RXD- RX Data Negative 13 RXD+ RX Data Positive 14 VeeR RX GND 15 VCCR RX Power 16 VCCT TX Power 17 VeeT TX GND 18 TXD+ TX Data Positive 19 TXD- TX Data Negative 20 VeeT TX GND LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 4 LUMNDS1356-Feb1607 Rev A.2 10Km Tri-rate SFP Transceiver SP-TR-LX Outline Drawing Units in mm(inches) LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 5 LUMNDS1356-Feb1607 Rev A.2 10Km Tri-rate SFP Transceiver SP-TR-LX Suggested Transceiver interface 1�H Vcc 10�F 1�H 0.1�F VCCT .01�F Protocol IC R1 LuminentOIC SFP 10K� TX_DISABLE TX_DISABLE TX_FAULT TX_FAULT TD + SerDes Laser Driver .01�F 100� TD VEET .01�F VCCR 10�F 0.1�F RD + Receiver Amplifier .01�F 100� RD - RX_LOS RX_LOS Vcc R VEER 1 R1 R1 .01�F EEPROM R1 MOD_DEF 2 MOD_DEF 1 MOD_DEF 0 R1=4.7K to 10K� LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 6 LUMNDS1356-Feb1607 Rev A.2 10Km Tri-rate SFP Transceiver SP-TR-LX Ordering Information Available Options: SP-TR-LX-CNA SP-TR-LX-TNA SP-TR-LX-CDA SP-TR-LX-TDA SP-TR-LX-CNC SP-TR-LX-TNC SP-TR-LX-CDC SP-TR-LX-TDC Part numbering Definition: SP - TR - LX - Temperature Diagnostic Revision - Customer Specific • SP = Small Form Pluggable TR = Tri-rate LX = 10km reach • Operating Temperature C = Commercial temperature (-5 to 70ºC) T = Industrial temperature (-40 to 85ºC) • D = Digital Diagnostic (SFF-8472) N = No Digital Diagnostic • Design Revision A = RoHS-5/6 compliant (lead exemption) C = RoHS-6/6 compliant (lead free soldering) • Blank = Standard Procedure Labelling, Serial number, or Shipping Instructions, etc. Warnings: Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow guidelines according to proper ESD procedures. Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation. Legal Notes: IMPORTANT NOTICE! All information contained in this document is subject to change without notice, at LuminentOIC’s sole and absolute discretion. LuminentOIC warrants performance of its products to current specifications only in accordance with the company’s standard one-year warranty; however, specifications designated as “preliminary” are given to describe components only, and LuminentOIC expressly disclaims any and all warranties for said products, including express, implied, and statutory warranties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the company’s Terms and Conditions of Sale for further warranty information. LuminentOIC assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and LuminentOIC makes no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this document are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. LuminentOIC customers using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify LuminentOIC for any damages resulting from such use or sale. THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN “AS IS” BASIS. Customer agrees that LuminentOIC is not liable for any actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact LuminentOIC to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current. © LuminentOIC, Inc. 2003 All rights reserved LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 7 LUMNDS1356-Feb1607 Rev A.2