120 km Gigabit Ethernet SFP Transceiver SP-GB-EZX Features • Data rate 1.062 to 1.25 Gb/s • Single 3.3 V supply • 120 km Reach • 32 dB min, 36 dB typical link budget • Commercial temperature available (-Cxx) • 1550 nm DFB laser • APD receiver • Digital Diagnostic SFF-8472 compliant • SFP MSA SFF-8074i compliant • Telcordia GR-468 compliant • Color coded bail latch: White • RoHS compliant General Operating Parameter Symbol Min. Typical Max. Unit Supply Voltage Vcc 3.135 3.3 3.465 V Total Current Icc - - 300 mA Power Supply Rejectiona PSR 100 - - mVp-p Operating Temperature Top -5 - 70 ºC Storage Temperature Tst -40 - 85 ºC Data Rate GbE DR - 1250 - Mbps Data Rate FC DR - 1062.5 - Mbps a) 20Hz to 155MHz Transmitter Specifications (Optical) Parameter Symbol Min Typical Max Unit Optical Power POP 0 2 5 dBm Average Launch Power Of Off Tx POff - - -45 dBm Extinction Ratio (Dynamic) ER 9 - - dB Eye Mask - - - 802.3ah compliant Total Jitter TJ - - 200 ps Optical Rise Timeb tr - - 260 ps Timeb tf - 260 ps λ 1535 1550 1565 nm Optical Fall Mean Wavelength ∆λ - - 1 nm SMSR 30 - - dB Optical Path Penalty at 120 Kmc dp - 1 2 dB Relative Intensity Noise RIN - - -120 dB/Hz Reflection Toleranced rp -24 - - dB Spectral Width (20dB) Side Mode Suppression Ratio b) 20%-80% values c) Measured at BER of 10-12, PRBS of 27-1, at eye center d) 1 dB degradation of receiver sensitivity LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 1 LUMNDS1535-Aug0407 Rev A.3 120 km Gigabit Ethernet SFP Transceiver SP-GB-EZX Transmitter Specifications (Electical) Parameter Symbol Min Typical Max Unit Rin 80 100 120 Ω PECL Single Ended Data Input Swing Vin,p-p 250 - 1200 mV TxFault_Fault Vfault 2 - Vcc V Vnormal Vee - Vee+0.5 V Vd 2 - Vcc V Ven Vee - Vee+0.8 V Parameter Symbol Min Typical Max Unit Receive Power Lowe Rsens,low - -34 -32 dBm Input Differential Impedence TxFault_Normal TxDisable_Disable TxDisable_Enable Receiver Specifications Receive Power Rsens,high -3 - - dBm Pin,damage 6 - - dBm λ 1500 1550 1580 nm Highe Damage Threshold For Receiver Wavelengthf Maximum Reflectance Of Receiver RX_r - - -14 dB -42 - - dBm LOS De-assert - - -32 dBm LOS Hysteresis 0.5 - - dB LOS Assert e) 10-12 at nominal wavelength f) Operational over 1200-1625nm range Electrical Output Parameter Symbol Min Typical Max Unit PECL Single Ended Data Output Swing Vout, p-p 185 - 800 mV Data Output Rise Time tr - - 175 ps Data Output Fall Time tf - - 175 ps Timing and Electrical Parameter Symbol Min Typical Max Unit t_on - - 1 ms Tx Disable Assert Time t_off - - 10 µs Time To Initialize, Including Reset Of Tx Fault t_init - - 300 ms Tx Disable Negate Time Tx Fault Assert Time t_fault - - 100 µs Tx Disable To Reset t_reset 10 - - µs t_loss_on - - 100 µs LOS Assert Time LOS De-assert Time t_loss_off - - 100 µs Serial ID Clock Rate f_serial_clock 2 - 100 KHz 2 - Vcc V RX_LOS Voltage (High) RX_LOS Voltage (Low) MOD_DEF (0:2)-High MOD_DEF (0:2)-Low LOS Output Voltage-Fault LOS Output Voltage-Normal LUMINENTOIC.COM - - 0.8 V VH 2 - Vcc V VL Vee - Vee+0.5 V VLOS fault 2 - Vcc V VLOSnormal Vee - Vee+0.55 V 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 2 LUMNDS1535-Aug0407 Rev A.3 120 km Gigabit Ethernet SFP Transceiver SP-GB-EZX Diagnostics Parameter Range Accuracy Unit Calibration Formula Temperature (-CDA) -5 to 70 ±3 ºC External Tc(C) = Tslope*Tad(16 bit signed twos complement value) + Toffset Voltage 0 to Vcc 0.1 V External V(Volts) = Vslope*Vad (16 bit unsigned integer) + Voffset Bias Current 0 to 120 5 mA External I(mA)=Islope*Iad(16 bit unsigned integer)+Ioffset TX Power 0 to 5 ±3 dB dBm External TX_PWR(µW)=TX_PWRslope*TX_PWRad(16 bit unsinged integer +TX_PWRoffset RX Power -32 to -3 ±3 dB dBm External RX_PWR(µW)=A0+A1*x+A2*x^2+A3*x^3+A4*x^4 EEPROM Serial ID Name of Field Vendor Name Vendor OUI Vendor PN LUMINENTOIC.COM Description of Field SFP Vendor Name(ASCII) IEEE Vendor OUI Code For LuminentOIC Inc. Part Number in ASCII, e.g. SP-GB-EZX-CDA Address Hex 20 4C L 21 55 U 22 4D M 23 49 I 24 4E N 25 45 E 26 4E N 27 54 T 28 4F O 29 49 I 30 43 C 37 00 38 06 39 B5 40 53 S 41 50 P 42 47 G 43 42 B 44 45 E 45 5A Z 46 58 X 47 43 C 48 44 D 49 41 A 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 3 ASCII LUMNDS1535-Aug0407 Rev A.3 120 km Gigabit Ethernet SFP Transceiver SP-GB-EZX Pinout Definitions Pin Function Notes 1 VeeT TX GND 2 TX_FAULT Open Collector 3 TX_DISABLE Internally Pulled High 4 MOD_DEF2 Serial Data Input 5 MOD_DEF1 Serial Clock Input 6 MOD_DEF0 Internally Grounded 7 NC Not Connected 8 LOS Open Collector 9 VeeR RX Ground 10 VeeR RX Ground 11 VeeR RX Ground 12 RXD- RX Data Negative 13 RXD+ RX Data Positive 14 VeeR RX GND 15 VCCR RX Power 16 VCCT TX Power 17 VeeT TX GND 18 TXD+ TX Data Positive 19 TXD- TX Data Negative 20 VeeT TX GND LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 4 LUMNDS1535-Aug0407 Rev A.3 120 km Gigabit Ethernet SFP Transceiver SP-GB-EZX Outline Drawing Units in mm(inches) LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 5 LUMNDS1535-Aug0407 Rev A.3 120 km Gigabit Ethernet SFP Transceiver SP-GB-EZX Suggested Transceiver interface 1�H Vcc 10�F 1�H 0.1�F VCCT .01�F Protocol IC R1 LuminentOIC SFP 10K� TX_DISABLE TX_DISABLE TX_FAULT TX_FAULT TD + SerDes Laser Driver .01�F 100� TD VEET .01�F VCCR 10�F 0.1�F RD + Receiver Amplifier .01�F 100� RD - RX_LOS RX_LOS Vcc R VEER 1 R1 R1 .01�F EEPROM R1 MOD_DEF 2 MOD_DEF 1 MOD_DEF 0 R1=4.7K to 10K� LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 6 LUMNDS1535-Aug0407 Rev A.3 120 km Gigabit Ethernet SFP Transceiver SP-GB-EZX Ordering Information Available Options: SP-GB-EZX-CDA SP-GB-EZX-CNA Part numbering Definition: SP - GB - EZX - Temperature Diagnostic Revision • SP = Small Form Pluggable GB = 1.25G EZX = IEEE 802.3ah 120 km • Operating Temperature C = Commercial temperature (-5 to 70ºC) • D = Digital Diagnostic (SFF-8472) N = No Digital Diagnostic • Design Revision A = RoHS compliant Warnings: Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow guidelines according to proper ESD procedures. Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation. Legal Notes: IMPORTANT NOTICE! All information contained in this document is subject to change without notice, at LuminentOIC’s sole and absolute discretion. LuminentOIC warrants performance of its products to current specifications only in accordance with the company’s standard one-year warranty; however, specifications designated as “preliminary” are given to describe components only, and LuminentOIC expressly disclaims any and all warranties for said products, including express, implied, and statutory warranties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the company’s Terms and Conditions of Sale for further warranty information. LuminentOIC assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and LuminentOIC makes no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this document are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. LuminentOIC customers using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify LuminentOIC for any damages resulting from such use or sale. THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN “AS IS” BASIS. Customer agrees that LuminentOIC is not liable for any actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact LuminentOIC to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current. © LuminentOIC, Inc. 2003 All rights reserved LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 7 LUMNDS1535-Aug0407 Rev A.3