SOURCE SP-GB-YX-TDA

60 Km Gigabit Ethernet SFP Transceiver
SP-GB-YX
Features
• Data rate 1.062 to 1.25 Gb/s
• Single 3.3 V supply
• 60 km reach
• 22 dB min link budget
• 1550 nm DFB laser
• SFP MSA SFF-8074i compatible
• Digital Diagnostic SFF-8472 compliant
• Bellcore GR-468 compliant
• RoHS-5 compliance (lead exemption)
• Color coded bail latch tube: Green
General Operating
Parameter
Symbol
Min.
Typical
Max.
Unit
Supply Voltage
Vcc
3.135
3.3
3.465
V
Total Current (-CDA)
Icc
-
-
300
mA
Total Current, Each Power Supply pin,
-40ºC to -5ºC (-TDA)
Icc
-
-
500
mA
Total Current, Each Power Supply pin,
-5ºC to -85ºC (-TDA)
Icc
-
-
300
mA
Power Supply Rejectiona
PSR
100
-
-
mVp-p
Operating Temperature (-CXX)
Top
-5
-
70
ºC
Operating Temperature (-TXX)
Top
-40
-
85
ºC
Storage Temperature
Tst
-40
-
85
ºC
Data Rate GbE
DR
-
1250
-
Mbps
Data Rate FC
DR
-
1062.5
-
Mbps
Symbol
Min
Typical
Max
Unit
Optical Power
POP
-2
+0.5
+3
dBm
Average Launch Power Of Off Tx
POff
-
-
-30
dBm
Extinction Ratio (Dynamic)
ER
9
-
-
dB
TJ
-
-
200
ps
Timeb
tr
-
-
260
ps
Optical Fall Timeb
tf
-
Mean Wavelength
λ
1500
a) 20Hz to 155MHz
b) deviations from the MSA
Transmitter Specifications (Optical)
Parameter
Eye Mask
802.3 ah compliant
Total Jitter
Optical Rise
260
ps
1550
1580
nm
Δλ
-
-
1
nm
SMSR
30
-
-
dB
Optical Path Penalty at 60 Kmc
dp
-
1
2
dB
Relative Intensity Noise
RIN
-
-
-120
dB/Hz
Reflection Toleranced
rp
-
-
-24
dB
Spectral Width (20dB)
Side Mode Suppression Ratio
c) 20%-80% values
d) Measured at BER of 10-12, PRBS of 27-1, at eye center
e) 1dB degradation of receiver sensitivity
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
1
LUMNDS1559-Jul2406
Rev. A.1
60 Km Gigabit Ethernet SFP Transceiver
SP-GB-YX
Transmitter Specifications (Electical)
Parameter
Symbol
Min
Typical
Max
Unit
Rin
80
100
120
Ω
PECL Single Ended Data Input Swing
Vin,p-p
250
-
1200
mV
TxFault_Fault
Vfault
2
-
Vcc
V
Vnormal
Vee
-
Vee+0.5
V
Vd
2
-
Vcc
V
Ven
Vee
-
Vee+0.8
V
Symbol
Min
Typical
Max
Unit
Input Differential Impedence
TxFault_Normal
TxDisable_Disable
TxDisable_Enable
Receiver Specifications
Parameter
Receive Power Lowe
Rsens,low
-
-26
-24
dBm
Receive Power High
Rsens,high
-3
0
-
dBm
Damage Threshold For Receiver
Pin,damage
-
-
6
dBm
λ
1200
-
1625
nm
RX_r
-
-
-12
dB
-38
-
-
dBm
LOS De-assert
-
-
-24
dBm
LOS Hysteresis
0.5
-
-
dB
Wavelength
Maximum Reflectance Of Receiver
LOS Assert
f) at
10-7BER,
PRBS
27-1
Electrical Output
Parameter
Symbol
Min
Typical
Max
Unit
PECL Single Ended Data Output Swing
Vout, p-p
185
-
800
mV
Data Output Rise Time
tr
-
-
260
ps
Data Output Fall Time
tf
-
-
260
ps
Timing and Electrical
Symbol
Min
Typical
Max
Unit
Tx Disable Negate Time
Parameter
t_on
-
-
1
ms
Tx Disable Assert Time
t_off
-
-
10
µs
t_init
-
-
300
ms
Tx Fault Assert Time
Time To Initialize, Including Reset Of Tx Fault
t_fault
-
-
100
µs
Tx Disable To Reset
t_reset
10
-
-
µs
LOS Assert Time
t_loss_on
-
-
100
µs
LOS De-assert Time
t_loss_off
-
-
100
µs
Serial ID Clock Rate
f_serial_clock
2
-
100
KHz
RX_LOS Voltage (High)
2
-
Vcc
V
RX_LOS Voltage (Low)
-
-
0.8
V
MOD_DEF (0:2)-High
VH
2
-
Vcc
V
MOD_DEF (0:2)-Low
VL
Vee
-
Vee+0.5
V
VLOS fault
2
-
Vcc
V
VLOSnormal
Vee
-
Vee+0.5
V
LOS Output Voltage-Fault
LOS Output Voltage-Normal
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
2
LUMNDS1559-Jul2406
Rev. A.1
60 Km Gigabit Ethernet SFP Transceiver
SP-GB-YX
Diagnostics
Range
Accuracy
Unit
Calibration
Temperature (-CDA)
-5 to 70
±3
ºC
Internal
Tc(C)=Tad(16 bit signed twos complement)/256
Temperature (-TDA)
-40 to 85
±3
ºC
Internal
Tc(C)=Tad(16 bit signed twos complement)/256
Voltage
0 to Vcc
± 0.1
V
Internal
V(Volts)=Vad(16 bit unsigned integer)*0.1
Bias Current
0 to 120
±5
mA
External
I(mA)=Islope*Iad(16 bit unsigned integer)+Ioffset
TX Power
-2 to +3
±3 dB
dBm
External
TX_PWR(µW)=TX_PWRslope*TX_PWRad(16 bit unsigned
integer +TX_PWRoffset
RX Power
-24 to -3
±3 dB
dBm
External
RX_PWR(µW)=A0+A1*x+A2*x^2+A3*x^3+A4*x^4
Parameter
Formula
EEPROM Serial ID
Name of Field
Vendor Name
Vendor OUI
Vendor PN
LUMINENTOIC.COM
Description of Field
Address
Hex
20
4C
L
21
55
U
22
4D
M
23
49
I
24
4E
N
25
45
E
26
4E
N
27
54
T
28
4F
O
29
49
I
30
43
C
37
00
38
06
39
B5
40
53
S
41
50
P
42
47
G
43
42
B
44
59
Y
45
58
X
46
43
C
47
44
D
48
41
A
SFP Vendor Name(ASCII)
IEEE Vendor OUI Code For LuminentOIC Inc.
Part Number in ASCII, e.g.
SP-GB-YX-CDA
ASCII
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
3
LUMNDS1559-Jul2406
Rev. A.1
60 Km Gigabit Ethernet SFP Transceiver
SP-GB-YX
Pin
Function
Notes
1
VeeT
TX GND
2
TX_FAULT
Open Collector
3
TX_DISABLE
Internally Pulled High
4
MOD_DEF2
Serial Data Input
5
MOD_DEF1
Serial Clock Input
6
MOD_DEF0
Internally Grounded
7
NC
Not Connected
8
LOS
Open Collector
9
VeeR
RX Ground
10
VeeR
RX Ground
11
VeeR
RX Ground
12
RXD-
RX Data Negative
13
RXD+
RX Data Positive
14
VeeR
RX GND
15
VccR
RX Power Supply
16
VccT
TX Power Supply
17
VeeT
TX GND
18
TXD+
TX Data Positive
19
TXD-
TX Data Negative
20
VeeT
TX GND
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
4
LUMNDS1559-Jul2406
Rev. A.1
60 Km Gigabit Ethernet SFP Transceiver
SP-GB-YX
Outline Drawing
Units in mm(inch)
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
5
LUMNDS1559-Jul2406
Rev. A.1
60 Km Gigabit Ethernet SFP Transceiver
SP-GB-YX
Suggested Transceiver Interface
1�H
Vcc
10�F
1�H
0.1�F
VCCT
.01�F
Protocol IC
LuminentOIC
SFP
10K�
R1
TX_DISABLE
TX_DISABLE
TX_FAULT
TX_FAULT
TD +
SerDes
Laser Driver
.01�F
100�
TD VEET
.01�F
VCCR
10�F
0.1�F
RD +
Receiver Amplifier
.01�F
100�
RD -
RX_LOS
RX_LOS
Vcc
R
VEER
1
R1
R1
.01�F
EEPROM
R1
MOD_DEF 2
MOD_DEF 1
MOD_DEF 0
R1=4.7K to 10K�
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
6
LUMNDS1559-Jul2406
Rev. A.1
60 Km Gigabit Ethernet SFP Transceiver
SP-GB-YX
Ordering Information
Available Options:
SP-GB-YX-CDA
SP-GB-YX-CNA
SP-GB-YX-TDA
SP-GB-YX-TNA
Part numbering Definition:
SP - GB - YX - Temperature Diagnostic
Revision
• SP = Small Form Pluggable
GB = 1.25 Gbps
YX = Extended Reach 60 km
• Operating Temperature
C = Commercial (-5 to 70ºC)
T = Industrial (-40 to 85ºC)
• D = Digital Diagnostic (SFF-8472)
N = No Digital Diagnostic
• Design Revision
Warnings:
Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow
guidelines according to proper ESD procedures.
Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation.
Legal Notes:
IMPORTANT NOTICE!
All information contained in this document is subject to change without notice, at LuminentOIC’s sole and absolute discretion. LuminentOIC warrants performance
of its products to current specifications only in accordance with the company’s standard one-year warranty; however, specifications designated as “preliminary” are
given to describe components only, and LuminentOIC expressly disclaims any and all warranties for said products, including express, implied, and statutory warranties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the company’s Terms and Conditions of
Sale for further warranty information.
LuminentOIC assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual
property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and LuminentOIC makes
no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this document are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. LuminentOIC customers
using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify LuminentOIC for any damages resulting from
such use or sale.
THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN “AS IS” BASIS. Customer agrees that LuminentOIC is not liable for any
actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact
LuminentOIC to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current.
© LuminentOIC, Inc. 2003
All rights reserved
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
7
LUMNDS1559-Jul2406
Rev. A.1