SOURCE SPS-34-GB-BX-TDC

SFP Bi-Directional Transceiver
SPS-34-GB-BX
Features
• Compliant with IEEE 802.3ah, 1000Base BX
• Simplex SC Connector
• Digital Diagnostic SFF-8472 Compliant
• 11dB Minimum Power Budget
• 10km Minimum Reach
• Commercial Temperature Operation
• Single 3.3V Supply
• 1310nm FP Laser
• Bellcore GR-468 Compliant
• Color Coded Bail Latch: Blue
• RoHS-5/6 compliant product (lead exemption) (-xxA)
• RoHS compliant product (-xxC)
General Operation
Parameter
Symbol
Min.
Typ.
Max.
Supply Voltage
Vcc
3.135
3.3
3.465
V
Total Current
ICC
-
-
300
mA
Power Supply Noise Rejection
Unit
100
-
-
mVp-p
Operating Case Temperature (-Cxx)
Topr
-5
-
70
ºC
Operating Case Temperature (-Txx)
Topr
-40
-
85
ºC
Storage Temperature
Tstg
-40
-
85
ºC
Data Rate
DR
-
1250
-
Mbps
Transmitter Specifications (Optical)
Parameter
Symbol
Min
Typical
Max
Unit
Optical Power
Pop
-9
-6
-3
dBm
Optical Crosstalk
XT
-
-45
-40
dB
Average Launch Power (Tx:Off)
Poff
-
-
-45
dBm
Extinction Ratio
ER
6
-
-
dB
Optical Rise Time (20% to 80% values)
tr
-
-
260
ps
Optical Fall Time (20% to 80% values)
tf
-
-
260
ps
Mean Wavelength
λ
1260
1310
1360
nm
Eye Mask
IEEE 802.3ah
σ
-
-
3.5
nm
Relative Intensity Noise
RIN
-
-
-120
dB/Hz
Transmitter Reflectance
-
-
-
-12
dB
ORLT
-
-
12
dB
Spectral Width (RMS)
Optical Return Loss Tolerance
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
1
LUMNDS112-Dec1106
Rev A.4
SFP Bi-Directional Transceiver
SPS-34-GB-BX
Transmitter Specifications (Electrical)
Parameter
Input Differential Impedence
PECL Single-Ended Data Input Swing
TxFault_Fault
Symbol
Min
Typical
Max
Rin
80
100
120
Unit
Ω
Vin, p-p
250
-
1200
mV
Vfault
2
-
Vcc
V
Vee
-
Vee + 0.5
V
TxDisable_Disable
Vnormal
Vd
2
-
Vcc
V
TxDisable_Enable
Ven
Vee
-
Vee + 0.8
V
Parameter
Symbol
Min
Typical
Max
Unit
Receiver Power Lowa
Rsens,low
-
-22
-20
dBm
Receiver Power High
Rsens,high
-3
-
-
dBm
Damage Threshold for Receiver
Pin, damage
0
-
-
dBm
λ
1480
-
1580
nm
LOS Assert
-
-45
-
-
dBm
LOS De-Assert
-
-
-
-20
dBm
LOS Hysteresis
-
0.5
-
-
dB
Receiver Reflectance
-
-
-
-12
dB
TxFault_Normal
Receiver Specifications (Optical)
a
Wavelengthb
a) Measured at 10-12 BER, PRBS 27-1, 6dB ER
b) Receiver performance can be maintained over a broader wavelength range of 1480 to 1580nm
Receiver Specifications (Electrical)
Parameter
Symbol
Min
Typical
Max
Unit
PECL Single-Ended Data Output Swing
Vout,p-p
185
-
800
mV
Data Output Rise Time
tr
-
-
500
ps
Data Output Fall Time
tf
-
-
500
ps
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
2
LUMNDS112-Dec1106
Rev A.4
SFP Bi-Directional Transceiver
SPS-34-GB-BX
Timing and Electrical
Parameter
Symbol
Min
Typical
Max
Unit
Tx Disable Negate Time
t_on
-
-
1
ms
Tx Disable Assert Time
t_off
-
-
10
µs
Time to Initialize, Including Reset of Tx Fault
t_init
-
-
300
ms
Tx Fault Assert Time
t_fault
-
-
100
µs
Tx Disable to Reset
t_reset
10
-
-
µs
t_loss_on
-
-
100
µs
t_loss_off
f_serial_clock
Rx_LOSH
2
-
100
100
-
µs
KHz
V
LOS Assert Time
LOS De-Assert Time
Serial ID Clock Rate
RX_LOS Voltage (High)
RX_LOS Voltage (Low)
RX_LOSL
-
-
0.8
V
LOS Output Voltage-Fault
VLOS fault
2
-
Vcc
V
VLOS normal
Vee
-
Vee + 0.5
V
MOD_DEF (0:2)-High
Vh
2
-
V
MOD_DEF (0:2)-Low
VI
Vee
-
Vcc
Vee + 0.5
LOS Output Voltage-Normal
V
Diagnostics
Parameter
Range
Accuracy
Unit
Calibration
Bit Value
Formula
Temperature (-CDx)
-5 to 70
±3
ºC
Internal
1/256 C
Tc(C) = Tad(16 bit signed twos complement)/256
Temperature (-TDx)
-40 to 85
±3
ºC
Internal
1/256 C
Tc(C) = Tad(16 bit signed twos complement)/256
Voltage
0 to Vcc
0.1
V
Internal
100µV
V(Volts) = Vad(16 bit unsigned integer)*0.1
Bias Current
0 to 120
5
mA
External
-
I(mA) = Islope * Iad(16 bit unsigned integer)+Ioffset
Tx Power
-9 to -3
±3dB
mW
External
-
Tx_PWR(µW) = Tx_PWRslope*Tx_PWRad(16 bit unsigned
integer)+Tx_PWRoffset
Rx Power
-20 to -3
±3dB
mW
External
-
Rx_PWR(µW) = A0+A1*x+A2*x^2+A3*x^3+A4*x^4
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
3
LUMNDS112-Dec1106
Rev A.4
SFP Bi-Directional Transceiver
SPS-34-GB-BX
EEPROM Serial ID
Name of Field
Vendor Name
Vendor OUI
Vendor P/N
LUMINENTOIC.COM
Discription of Field
SFP Vendor name (ASCII)
IEEE vendor OUI code for Luminent Inc.
Part number in ASCII, e.g.
SPS-34-GB-BX-CDA
Address
Hex
20
4C
L
21
55
U
22
4D
M
23
49
I
24
4E
N
25
45
E
26
4E
N
27
54
T
28
4F
O
29
49
I
30
43
C
37
00
38
06
39
B5
40
53
S
41
50
p
42
53
S
43
33
3
44
34
4
45
47
G
46
42
B
47
42
B
48
58
X
49
43
C
50
44
D
51
41
A
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
4
ASCII
LUMNDS112-Dec1106
Rev A.4
SFP Bi-Directional Transceiver
SPS-34-GB-BX
Pinout Definitions
Pin
Function
Notes
1
VeeT
TX GND
2
TX_FAULT
Open Collector
3
TX_DISABLE
Internally Pulled High
4
MOD_DEF2
Serial Data Input
5
MOD_DEF1
Serial Clock Input
6
MOD_DEF0
Internally Grounded
7
NC
Not Connected
8
LOS
Open Collector
9
VeeR
RX Ground
10
VeeR
RX Ground
11
VeeR
RX Ground
12
RXD-
RX Data Negative
13
RXD+
RX Data Positive
14
VeeR
RX GND
15
VCCR
RX Power
16
VCCT
TX Power
17
VeeT
TX GND
18
TXD+
TX Data Positive
19
TXD-
TX Data Negative
20
VeeT
TX GND
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
5
LUMNDS112-Dec1106
Rev A.4
SFP Bi-Directional Transceiver
SPS-34-GB-BX
Mechanicals
Units in mm(inches)
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
6
LUMNDS112-Dec1106
Rev A.4
SFP Bi-Directional Transceiver
SPS-34-GB-BX
Suggested Transceiver Interface
1�H
Vcc
10�F
1�H
0.1�F
VCCT
.01�F
Protocol IC
LuminentOIC
SFP
10K�
R1
TX_DISABLE
TX_DISABLE
TX_FAULT
TX_FAULT
TD +
SerDes
Laser Driver
.01�F
100�
TD VEET
.01�F
VCCR
10�F
0.1�F
RD +
Receiver Amplifier
.01�F
100�
RD -
RX_LOS
RX_LOS
Vcc
R
VEER
1
R1
R1
.01�F
EEPROM
R1
MOD_DEF 2
MOD_DEF 1
MOD_DEF 0
R1=4.7K to 10K�
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
7
LUMNDS112-Dec1106
Rev A.4
SFP Bi-Directional Transceiver
SPS-34-GB-BX
Ordering Information
Available Options: SPS-34-GB-BX-CNA
SPS-34-GB-BX-CDA
SPS-34-GB-BX-TNA
SPS-34-GB-BX-TDA
SPS-34-GB-BX-CNC
SPS-34-GB-BX-CDC
SPS-34-GB-BX-TNC
SPS-34-GB-BX-TDC
Part Numbering Definition:
SPS - 34 - GB - BX
-
Temperature Diagnostic Revision
• SPS = SC connector
• Wavelength
34 = Tx 1310nm/Rx 1490nm
• Data Rate
GB = Gigabit Ethernet
• Standard
BX = 1000BASE-BX
• Operatating Temperature
C= Commercial temperature (-5 to 70ºC)
T= Industrial temperature (-40 to 85ºC)
• Diagnostic
D = Digital Diagnostic
N = No Diagnostic
• Ordering Information
A=RoHS 5/6-compliant product (lead exemption)
C=RoHS 6/6-compliant (no exemption)
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
8
LUMNDS112-Dec1106
Rev A.4
SFP Bi-Directional Transceiver
SPS-34-GB-BX
Warnings:
Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow
guidelines according to proper ESD procedures.
Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation.
Legal Notes:
IMPORTANT NOTICE!
All information contained in this document is subject to change without notice, at Luminent’s sole and absolute discretion. Luminent warrants performance of its
products to current specifications only in accordance with the company’s standard one-year warranty; however, specifications designated as “preliminary” are given to
describe components only, and Luminent expressly disclaims any and all warranties for said products, including express, implied, and statutory warranties, warranties
of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the company’s Terms and Conditions of Sale for further
warranty information.
Luminent assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual property
described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and Luminent makes no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this document are NOT
intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. Luminent customers using or selling
products for use in such applications do so at their own risk and agree to fully defend and indemnify Luminent for any damages resulting from such use or sale.
THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN “AS IS” BASIS. Customer agrees that Luminent is not liable for any actual,
consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact
Luminent to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current.
© Luminent, Inc. 2003
All rights reserved
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
9
LUMNDS112-Dec1106
Rev A.4