Double Balanced Mixer Model M57 RF Band RF 10 to 1500 MHz Electrical Specifications (1) : Conditions Parameter SSB Conversion loss:(2) RF(MHz) 10-1000 10-1500 Isolation LO to RF: Specifications IF(MHz) DC-500 DC-1000 Min Typical 7.5 dB 8.5 dB 10-500 500-1500 35 dB 30 dB 30 dB 25 dB 10-1500 10-500 500-1500 10-1500 DC-1000 +17 dBm 10-1500 10-1500 10-1500 10-1500 DC-1000 DC-1000 +15 dBm +27 dBm 10-1500 10-1500 DC-1000 +23 dBm LO to IF: Input 1-dB Compression Point: Desensitization Point: Input Third Order Intercept Point: LO Power: (3) LO(MHz) 10-1000) 10-1500 Max 8.0 dB 9.5 dB Notes: 1. Specifications are guaranteed when tested as a downconverter in a 50 Ohm system at +25˚C with the nominal LO power. Specifications indicated as typical are not guaranteed. 2. SSB Noise figure is nominally within ±0.5 dB of the SSB conversion loss for IF frequencies greater than 10 MHz. 3. Usable LO drives are up to 2 dB below and 3 dB above nominal. Typical Performance at 25˚C Outline: TO-8 M57T SPECTRUM ECTRU MICROWAVE INC. M SP All dimensions are in inches and [mm]. A Spectrum Control Business SPECTRUM MICROWAVE • 2144 Franklin Drive N.E. • Palm Bay, Florida 32905 • Phone: (888) 553-7531 • Fax: (888) 553-7532 www.specwave.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 594