Model MM9xMS-1 Model MM9xMS-17 Double Balanced Mixer Ultra-Broadband : Conditions Parameter SSB Conversion loss:(2) (3) RF(GHz) 3.0-19.0 1.8-20.0 1.8-20.0 Isolation LO to RF: LO to IF: LO(GHz) 3.0-19.0 1.8-20.0 1.8-20.0 IF(MHz) Min DC-400 DC-400 DC-800 1.8-20.0 4.0-19.0 1.8-20.0 20 dB 15 dB 12 dB RF to IF: IF to RF: Input 1-dB Compression Point: 1.8-20.0 1.8-20.0 1.8-20.0 DC-800 DC-800 Input Third Order Intercept Point: 1.8-20.0 1.8-20.0 DC-800 1.8-20.0 1.8-20.0 DC-800 LO Power: (4) Specifications Typical 5.5 dB 5.8 dB 7.2 dB Max 7.5 dB 8.5 dB 10.5 dB 28 dB 23 dB 22 dB 28 dB 40 dB +2 dBm +5 dBm +8 dBm +12 dBm +11 dBm +14 dBm +17 dBm +23 dBm +7 dBm +10 dBm +14 dBm +18 dBm MM93 MM94 MM96 MM97 MM93 MM94 MM96 MM97 MM93 MM94 MM96 MM97 Notes: 1. Specifications are guaranteed when tested as a downconverter in a 50 Ohm system at +25˚C with the nominal LO power. Specifications indicated as typical are not guaranteed. 2. Noise figure is typically within ±0.5 dB of conversion loss for IF frequencies greater than 10 MHz. 3. Conversion loss typically degrades less than 0.5 dB at +100˚C and improves less than 0.5 dB at -55˚C. 4. Usable LO drives are up to 2 dB below and 3 dB above nominal. 5. See Application Note M112, for aid in selecting the outline and for mounting and installation information. MM9xMS-1 Outline: MS3C MM9xMS-17 Outline: MS3D LO Power 3 = +7 dBm 4 = +10 dBm 6 = +14 dBm 7 = +19 dBm Mixers Electrical Specifications RF 1.8 to 20.0 GHz (1) Typical Performance at 25˚C ECTRU MHz MICROWAVE INC. M SP All dimensions are in inches and [mm]. A Spectrum Control Business SPECTRUM MICROWAVE • 2144 Franklin Drive N.E. • Palm Bay, Florida 32905 • Phone: (888) 553-7531 • Fax: (888) 553-7532 www.specwave.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 635