KUA0055A Reflector Sensor Features Function Product features Reflector Sensor for Short Distance (Digital Output) ・ Outer Dimension : 23.7 x 9.3 x 11.4 mm (L x W x H) ・Supply Voltage (Vcc) = 5V (Supply Voltage (Vcc) = 3V is available.) ・Integrated IRED and Photo IC ・Compact Small Package ・Detection Distance : 1 mm~7.5 mm ・RoHS compliant Installation method Snap On and Connector Packing Tray Recommended Applications Copier, Printer (Detection of Paper Jam, Paper Loading Timing and Paper Size) 2006.12.13 Page 1 KUA0055A Reflector Sensor Absolute Maximum Ratings Item (Ta=25℃, Except Topr, Tstg, Hopr and Hstg) Symbol Absolute Maximum Rating Conditions Unit Supply Voltage Vcc -0.5 ~ 7 V Output Voltage Vout 12 V Output Current Io 50 mA Operating Temperature Topr -10~+85 ℃ Storage Temperature Tstg -40~+85 ℃ Operating Humidity No Dew Hopr 15~+95 % Storage Humidity No Dew Hstg 15~+95 % Acceptable Ambient Illuminate Under Fluorescent Lamps and Incandescent Lamps Ex 3,000 lx Electro-Optical Characteristics Item Current Consumption (Ta=25℃, Vcc=5V, RL=1kΩ, Ambient Brightness=0lx) Symbol Conditions Average High Level Output Voltage 20 MAX. 150 VOH MIN. 4.5 V 0.4 V Low Level Output Voltage (At the time of Detecting) Transistor On VOL MAX. Output Open Collector Vout (At the time of Detecting) Transistor On Response Time Rise Time/Fall Time Kodak 90% reflective paper Tracing paper OHP Regular paper tr/tf MAX. 1 MIN. 1.0 MAX. 7.5 Black paper LHL MIN. 3.0 MAX. 7.0 90% Reflective Paper (White Paper) LLH MIN. 27 - MAX. 1.5±0.5 1.5±0.5 φ10 Detection Distance Undetectable Distance Detection Accuracy Detection Range 2006.12.13 Detection Distance : 6 mm From Ootical Center X1 X2 Unit MAX. Icc Peak Characteristics mA ms mm LHL mm mm mm mm Page 2 KUA0055A Reflector Sensor Package Dimensions 2006.12.13 (Unit: mm) Page 3 KUA0055A Reflector Sensor Reliability Testing Result Reliability Testing Result Applicable Standard Wet High Temp. Operaing Life EIAJ ED4701/100(102) Ta = 85℃, RH = 85%, VCC = 5V 1,000 h 0/5 Wet High Temp. Storage Life EIAJ ED4701/100(103) Ta = 85℃, 95% 1,000 h 0/5 High Temp. Operating Life EIAJ ED4701/100(101) Ta = 85℃, VCC = 5V 1,000 h 0/5 Low Temp. Operating Life EIAJ ED4701/100(101) Ta = -10℃, VCC = 5V 1,000 h 0/5 Thermal Shock EIAJ ED-40℃ ~ 85℃ 4701/200/(203) 200 cycles 0/5 30min 0/3 3 times 0/3 Testing Conditions Duration Failure 2 Vibration, Variable Frequency EIAJ ED4701/400(403) 9.8m/s (1G), 10 ~ 55 ~ 10Hz sweep for 60s, XYZ each direction(State of packing) Shock EIAJ ED4701/400(404) 294m/s (30G), XYZ each direction (State of packing) Terminal Strength EIAJ ED4701/400(401) Pull : 20N 5s Bend : 10N 5s Electric Static Discharge (ESD) EIAJ ED4701/300(304) C = 100pF, R = 1.5KΩ, ±1KV 2 once each terminal 0/Each 5 0/3 Failure Criteria Items Failure criteria Electro Characteristics The Rated Values of Electro Characteristics is satisfied. Cosmetic Appearance Occurrence of notable decoloration, deformation and cracking 2007.8.31 Page 4 KUA0055A Reflector Sensor Special Notice to Customers Using the Products and Technical Information Shown in This Data Sheet 1) The technical information shown in the data sheets are limited to the typical characteristics and circuit examples of the referenced products. It does not constitute the warranting of industrial property nor the granting of any license. 2) For the purpose of product improvement, the specifications, characteristics and technical data described in the data sheets are subject to change without prior notice. Therefore it is recommended that the most updated specifications be used in your design. 3) When using the products described in the data sheets, please adhere to the maximum ratings for operating voltage, heat dissipation characteristics, and other precautions for use. We are not responsible for any damage which may occur if these specifications are exceeded. 4) The products that have been described to this catalog are manufactured so that they will be used for the electrical instrument of the benchmark (OA equipment, telecommunications equipment, AV machine, home appliance and measuring instrument). The application of aircrafts, space borne application, transportation equipment, medical equipment and nuclear power control equipment, etc. needs a high reliability and safety, and the breakdown and the wrong operation might influence the life or the human body. Please consult us beforehand if you plan to use our product for the usages of aircrafts, space borne application, transportation equipment, medical equipment and nuclear power control equipment, etc. except OA equipment, telecommunications equipment, AV machine, home appliance and measuring instrument. 5) In order to export the products or technologies described in this data sheet which are under the “Foreign Exchange and Foreign Trade Control Law,” it is necessary to first obtain an export permit from the Japanese government. 6) No part of this data sheet may be reprinted or reproduced without prior written permission from Stanley Electric Co., Ltd. 7) The most updated edition of this data sheet can be obtained from the address below: http://www.stanley-components.com 2007.8.31 Page 5