TRUMPower 120 WATT MEDICAL POWER ADAPTERS D E S C R IP T IO N TMP120 SERIES The TMP120 series of AC/DC switching power adapters are for 96 to 120 watts of continuous output power. They are enclosed in a 94V-1 rated case with an IEC 320/C14 or C18 inlet to mate with interchangeable AC power cord for world-wide use. All models meet CISPR 11 and FCC class B emission limits, and are designed for medical applications. Class I, Class II (LVD) RoHS F E AT U R E S ‧ ‧ ‧ ‧ ‧ ‧ ‧ Low safety ground leakage current Optional output connectors 100% burn-in 9 0 t o 2 6 4 VAC w i d e i n p u t r a n g e O v e r v o l ta g e a n d o v e r c u r r e n t p r o t e c t i o n s Optional IEC 320/C18 inlet with class II insulation C o m p l i a n t w i t h C E C a n d E n e r g y S ta r e f f i c i e n c y l e v e l I V r e q u i r e m e n ts ‧ No load power consumption less than 0.5W ‧ Av e r a g e a c t i v e e f f i c i e n c y ≥ 8 5 % ‧ C o m p l i a n t w i t h R o H S r e q u i r e m e n ts S a f e t y Sta n d a r d A p p r o va l s : UL 60601-1 CSA C22.2 No. 601.1 TÜV EN60601-1 I N P U T S P E C I F I C AT I O N S GENERAL SPECIFICATIONS I n p u t v o l ta g e : Switching frequency: Power factor: Efficiency: Hold-up time: Line regulation: Input frequency: Input current: 90 to 264VAC 47 to 63Hz 1.60A (rms) for 115 VAC 0.80A (rms) for 230 VAC 90µA max. @ 115 VAC/60Hz Earth leakage current: 150µA max. @ 230 VAC/50Hz (Class I) E n c l o s u r e l e a k a g e c u r r e n t : 90µA max. @ 264 VAC/50Hz (Class II) OUTPUT SPECIFICATIONS Output voltage/current: Total output power: Ripple and noise: Overvoltage protection: Overcurrent protection: Temperature coefficient: Transient response: See rating chart 120 watts maximum 2% peak to peak maximum Provided on output #1 only; set at 112 -140% of its nominal output voltage All outputs protected to short circuit conditions All outputs ±0.04%/ºC maximum Maximum excursion of 4% or better on all models, recovering to 1% of final value within 500µs after a 25% step load change E N V I R O N M E N TA L S P E C I F I C AT I O N S Operating temperature: Storage temperature: Relative humidity: Derating: 50KHz ~ 110KHz 0.98 typical at 115VAC 85% min. 15 msec minimum at 115VAC ±0.5% maximum at full load Inrush current: 60 amps @ 115VAC or 90 amps @230VAC, at 25ºC cold start Withstand voltage: 4000VAC from input to output 1500VAC from input to ground 500VAC from output to ground MTBF: 150,000 hours minimum at full load at 25ºC ambient, calculated per MIL-HDBK-217F EMC Performance (EN60601-1-2: 2001) E N 5 5 0 11 : Class B conducted, Class B radiated FCC: Class B conducted, Class B radiated VCCI: Class B conducted, Class B radiated EN61000-3-2: Harmonic distortion, Class A and D EN61000-3-3: Line flicker EN61000-4-2: ESD, ±8KV air and ±6KV contact EN61000-4-3: Radiated immunity, 3V/m EN61000-4-4: Fast transient/burst, ±2KV EN61000-4-5: Surge, ±1KV diff, ±2KV com. EN61000-4-6: Conducted immunity, 3Vrms EN61000-4-8: Magnetic field immunity, 3A/m E N 6 1 0 0 0 - 4 - 11 : Voltage dips, 30% reduction for 500ms, 60% reduction for 100ms and >95% reduction for 10ms 0 ºC t o + 6 0 ºC - 4 0 ºC t o + 8 5 ºC 5% to 95% non-condensing Derate from 100% at +40ºC linearly to 50% at +60ºC Tumbler Technologies + TRUMPower 3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: [email protected] ● Website: www.TRUMPower.com MEDICAL GRADE TMP120 SERIES OUTPUT VOLTAGE/CURRENT RATING CHART Output Product No. Vnom. Imin. Imax. Tol. Maximum Output Power TMP120-12 12V 0A 8.0A 5% 96W TMP120-15 15V 0A 7.0A 5% 105W TMP120-18 18V 0A 6.67A 5% 120W TMP120-19 19V 0A 6.32A 5% 120W TMP120-20 20V 0A 6.0A 5% 120W TMP120-24 24V 0A 5.0A 5% 120W TMP120-30 30V 0A 4.0A 5% 120W TMP120-36 36V 0A 3.34A 5% 120W TMP120-48 48V 0A 2.5A 5% 120W NOTES: 1. Ripple and noise: Peak-to-peak with 20MHz bandwidth and 10µF tantalum capacitor in parallel with a 0.1µF ceramic capacitor at rated line voltage and load ranges. 2. To order a model with IEC320/C18 inlet and class II insulation, add “C2”, e.g. TMP120-12-C2. MECHANICAL SPECIFICATIONS NOTES: 1. Dimensions shown in inch [mm] 2. Tolerance 0.02 [0.5] maximum 3. Weight: 780 grams approx. 4. Standard output connector is a male 4-pin power DIN. Please consult TRUMPower for other connector options 5. TMP120-12 and TMP120-15 output connectors are without lock. PIN CHART PIN Product No. TMP120-12 TMP120-18 TMP120-20 TMP120-30 TMP120-48 TMP120-15 TMP120-19 TMP120-24 TMP120-36 1 2 3 4 Shell Return Output +V Return Output +V AC Ground Tumbler Technologies + TRUMPower 3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: [email protected] ● Website: www.TRUMPower.com