60-90 WATT MEDICAL & ITE POWER SUPPLIES DESCRIPTION PMP90 SERIES (LVD) The PMP90 series of AC/DC switching power supplies are for RoHS 60-90 watts of continuous output power. They are enclosed in a 94V-1 rated polyphenylene-oxide case with an IEC320/C14 or IEC320/C18 inlet to mate with interchangeable cord for world-wide use. All models meet EN55011, EN55022 and FCC class B emission limits, and are designed for medical and ITE applications, not for life-supporting equipment. FEATURES z z z z z z z z z Low safety ground leakage current Both Class I and Class II models are certified to medical and ITE safety standards. W i d e i n p u t r a n g e 8 5 t o 2 6 4 VA C Optional output connectors 100% burn-in Overvoltage protection Overcurrent protection C o m p l i a n t w i t h C E C a n d E n e r g y St a r E f f i c i e n c y level IV requirements (except models P M P 9 0 - 1 0 , P M P 9 0 - 1 0 - 1 a n d P M P 9 0 - 11 ) * No load power consumption less than 0.5 W * Average active efficiency greater than 85% Compliant with RoHS requirements SAFETY STANDARD APPROVALS UL 60601-1, CSA C22.2 No. 601.1 File No. E178020 TÜV EN 60601-1 UL 60950-1, CSA C22.2 No. 60950-1 File No. E137410 TÜV EN 60950-1 GENERAL SPECIFICATIONS INPUT SPECIFICATIONS Switching frequency: 50-110 KHz Input voltage: 90-264 VAC Power factor: 0.98 Typical Input frequency: 47-63 Hz Efficiency: 85% min. (except 77% min. for PMP90-10, Input current: 1.20 A (rms) for 115 VAC PMP90-10-1, PMP90-11 and PMP90-12) 0.60 A (rms) for 230 VAC Hold-up time: 15 ms minimum at 110 VAC Earth leakage current: 180 μA max. @ 264 VAC, 63 Hz Line regulation: ±0.5% maximum at full load Touch current: 100 μA max. @ 264 VAC, 63 Hz Inrush current: 50 A @ 115 VAC or 100 A @ 230 VAC, at Withstand voltage: 4000 VAC from input to output, 25℃ cold start OUTPUT SPECIFICATIONS Output voltage /current: Maximum output power: Ripple and noise: Overvoltage protection: Overcurrent protection: Temperature coefficient: Transient response: 1500 VAC from input to ground, See rating chart. See rating chart. 100 mVp-p maximum on 5 V, 6 V and 9 V outputs, 1% maximum on other voltage outputs (12 V, 13.5 V …, 48 V etc.) Provided and set at 112-140% of its nominal output voltage Protected to short circuit conditions 500 VAC from output to ground MTBF: EMC Performance (IEC60601-1-2) EN55011/EN55022: ±0.04% /℃ maximum Maximum excursion of 4% or better on all models, recovering to 1% of final value within 500 us after a 25% step load change ENVIRONMENTAL SPECIFICATIONS Operating temperature: Storage temperature: Relative humidity: Derating: 150,000 hours at full load at 25℃ ambient , calculated per MIL-HDBK-217F 0℃ to +60℃ -40℃ to +85℃ 5% to 95% non-condensing Derate from 100% at +40℃ linearly to 50% at +60℃ Class B conducted, class B radiated FCC: Class B conducted, class B radiated VCCI: Class B conducted, class B radiated EN61000-3-2: Harmonic distortion, class A and D EN61000-3-3: Line flicker EN61000-4-2: ESD, ±8 KV air and ±6 KV contact EN61000-4-3: Radiated immunity, 3 V/m EN61000-4-4: Fast transient/burst, ±2 KV EN61000-4-5: Surge, ±1 KV diff., ±2 KV com. EN61000-4-6: Conducted immunity, 3 Vrms EN61000-4-8: Magnetic field immunity, 3 A/m EN61000-4-11: Voltage dip immunity, 30% reduction for 500 ms, 60% reduction for 100 ms, and >95% reduction for 10 ms 49 UNIVERSAL INPUT PMP90 MEDICAL & ITE SERIES OUTPUT VOLTAGE/CURRENT RATING CHART Model Class I PMP90-10 PMP90-10-1 PMP90-11 PMP90-12 PMP90-12-1 PMP90-13 PMP90-13-1 PMP90-13-2 PMP90-14 PMP90-16 PMP90-18 (1) Class II PMP90F-10 PMP90F-10-1 PMP90F-11 PMP90F-12 PMP90F-12-1 PMP90F-13 PMP90F-13-1 PMP90F-13-2 PMP90F-14 PMP90F-16 PMP90F-18 V1 5.0 V 6.0 V 9.0 V 12.0 V 13.5 V 15.0 V 18.0 V 19.0 V 24.0 V 30.0 V 48.0 V Min. Current 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A Output Max. Current 12.0 A 10.0 A 7.78 A 6.67 A 6.30 A 5.67 A 5.00 A 4.74 A 3.75 A 3.00 A 1.87 A Tol. ±5% ±5% ±5% ±5% ±5% ±5% ±5% ±5% ±5% ±5% ±5% Average Active Efficiency (typical) @ 115 / 230 Vac Max. Power 60 W 78 / 79 % 60 W 78 / 79 % 70 W 81 / 82 % 80 W 86 / 85% 85 W 86 / 85% 85 W 86 / 85 % 90 W 86 / 85 % 90 W 86 / 86 % 90 W 87 / 86 % 90 W 87 / 86 % 90 W 88 / 87 % Ripple & (2) Noise 100 mV 100 mV 100 mV 120 mV 135 mV 150 mV 180 mV 190 mV 240 mV 300 mV 480 mV NOTES: 1. Class I models are equipped with IEC320/C14 inlet, and class II models with IEC320/C18 inlet. 2. Ripple and noise is maximum peak-to-peak voltage value measured at output within 20 MHz bandwidth, at rated line voltage and output load ranges, and with a 10 μF tantalum capacitor in parallel with a 0.1 μF ceramic capacitor across the output. MECHANICAL SPECIFICATIONS OUTPUT POWER DERATING CURVE NOTES: 1. Dimensions shown in inches [mm] 2. Tolerance 0.02 [0.5] maximum 3. Weight: 658 grams (1.45 lbs.) approx. 4. Output connector is 4 pin plug without lock, mating with Kycon P/N KPJX-4S-S socket or equivalent. 5. Refer to Section titled “OPTIONAL OUTPUT CONNECTORS”. Add the suffix assigned for a selected connector to a wanted model number, e.g. PMP90-14-B1, for ordering. PIN CHART MODEL PMP90-10 PMP90-10-1 PMP90-11 PMP90-12 PMP90-12-1 PMP90-13 PMP90-13-1 PMP90-13-2 PMP90-14 PMP90-16 PMP90-18 PIN PMP90F-10 PMP90F-10-1 PMP90F-11 PMP90F-12 PMP90F-12-1 PMP90F-13 PMP90F-13-1 PMP90F-13-2 PMP90F-14 PMP90F-16 PMP90F-18 1 2 3 4 V1 Return +V1 V1 Return +V1 50