XPPOWER CCH400

ACDC
400/600 Watts
CCH400600 Series
xppower.com
•
Baseplate Cooled
•
High Efficiency up to 90%
•
40 °C to +70 °C Operation
•
Industrial & MILSTD461E EMC Compliance
•
Power Fail, Inhibit, Overtemp & Current Share
•
5V Standby Output
•
3 Year Warranty
Specification
Input
General
• 90-264 VAC
• 47-400 Hz(1)
• CCH400: 4.3/2.1 A typ. at 115/230 VAC,
CCH600: 6.3/3.1 A typ. at 115/230 VAC,
full load
Inrush Current
• 60 A max at 230 VAC, 25 °C cold start
Power Factor
• >0.9
Earth Leakage Current • 0.7/1.1 mA at 115/230 VAC at 60/50 Hz
Input Protection
• Internal F10 A/250 V fuse
Input Voltage
Input Frequency
Input Current
Switching Frequency
Signals
MTBF
• 89% typical
• 3000 VAC Input to Output,
1500 VAC Input to Ground,
500 VDC Output to Ground
• 30-333 kHz PFC, 51.1 kHz main and
138 kHz standby converter
• Power Fail, Inhibit, Current Share,
Overtemperature Warning and 5 V Standby
• 300 kHrs to MIL-HDBK-217F at 25 °C, GB
Environmental
Output
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Drift
Line Regulation
Load Regulation
Over/Undershoot
Transient Response
•
•
•
•
•
•
•
•
•
•
•
•
Ripple & Noise
•
Overvoltage Protection •
Overload Protection
•
Short Circuit Protection •
Temperature
Coefficient
Overtemp. Protection
Remote Sense
Remote On/Off
Efficiency
Isolation
•
12-48 VDC
±10%
±1% V1, ±3% V2
No minimum load required
Typically 1 s
50 ms typical
20 ms min
±0.2% after 20 min warm up
±0.5% max
±1% V1, ±5% V2 max
1% typical
4% max. deviation, recovery to within
1% in 500 µs for a 50-75-50% load
change
Typically 1% pk-pk V1, V2 2%,
20 MHz bandwidth
110-140% Vnom, recycle input to reset
105-140% V1 only
Continuous, approximately constant
current
0.05%/˚C
• Fitted
• Compensates for 0.5 V total voltage drop
• Uncommitted isolated optocoupler diode,
powered diode inhibits V1
Notes
1. Safety approvals cover frequency 47-63 Hz.
Operating Temperature • -40 ˚C to +70 ˚C ambient. Baseplate must
be maintained ≤+85 °C, see thermal
considerations
Cooling
• Baseplate, conduction cooling
Operating Humidity
• 95% RH, non-condensing
Storage Temperature • -40 ˚C to +85 ˚C
Operating Altitude
• 3000 m
Shock
• MIL-STD 810F Clause 516.5 proc 1
Vibration
• MIL-STD 810F figure 514.5C-17
EMC & Safety
Low Voltage PSU EMC • EN61204-3, high severity level
Emissions
• EN55022 level B conducted, level A
radiated, MIL-STD 461D-F, CE102
Harmonic Currents
• EN61000-3-2, class A
Voltage Flicker
• EN61000-3-3
Radiated Immunity
• EN61000-4-3, level 3 Perf Criteria A
EFT/Burst
• EN61000-4-4, level 3 Perf Criteria A
Surge
• EN61000-4-5, installation class 3
Perf Criteria A
Conducted Immunity
• EN61000-4-6, level 3 Perf Criteria A,
MIL-STD 461 CS114
Dips & Interruptions
• EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B
Safety Approvals
• IEC60950-1 CB report, UL60950-1, TUV
EN60950-1
Equipment Protection • Class I
Class
Output Power
411 W
411 W
409 W
411 W
603
603
605
603
W
W
W
W
ACDC
CCH400/600
Models and Ratings
Output Voltage V1
12.0 VDC
24.0 VDC
28.0 VDC
48.0 VDC
12.0
24.0
28.0
48.0
Output Current V1
34.0 A
17.0 A
14.5 A
8.5 A
VDC
VDC
VDC
VDC
50.0
25.0
21.5
12.5
Standby Supply V2
5.0 V/0.5 A
5.0 V/0.5 A
5.0 V/0.5 A
5.0 V/0.5 A
A
A
A
A
5.0
5.0
5.0
5.0
V/0.5
V/0.5
V/0.5
V/0.5
Model Number
CCH400PS12
CCH400PS24
CCH400PS28
CCH400PS48
A
A
A
A
CCH600PS12
CCH600PS24
CCH600PS28
CCH600PS48
Mechanical Details
8.43 (214.00)
-
Voltage Adjust.
Pin
1
2
3
4
5
6
7
8
9
10
Output Terminals (M4)
Torque 8 in-lb (0.9 Nm) max
Signals Connector
Exploded View
Signal Connector
Function
Current Share
Inhibit
Overtemp. Warning
Power Fail
+Sense
-Sense
-Standby
-Standby
+Standby
+Standby
Pin 2
Pin 1
Pin 10
Pin 9
4.02
(102.00)
0.30 (7.72)
Input Connector
3 Way AMP/Tyco
Input Connector
Connector: 10 WAY 2mm pitch p/n
MOLEX 87833-1031
Mating half: p/n MOLEX 51110-1056
Contact: p/n MOLEX 50394-8100
Pin
1
2
3
+
1.69
(43.00)
Input Connector
Function
Earth
Neutral
Line
Pin 3
Pin 2 Pin 1
7.84 (199.00)
4.21 (107.00)
0.59 (15.00)
M4 fixings in 6 positions
Max. screw penetration to be 0.16 (4.0)
from bottom face of baseplate
Torque 13.2 in-lb (1.5 Nm) max
Connector: 3 way AMP/Tyco
type MATE-N-LOK 1-350943-0
0.177 Ø (4.50)
thru in 4 positions
Mates with MATE-N-LOK 350766-1
3.48 (88.4)
2.83
(72.00)
Notes
1.18
(30.00)
1. All dimensions in inches (mm).
2. Tolerance .xx = ±0.02 (0.50);
.xxx = ±0.01 (0.25)
3. Weight 3.3 lbs (1.5 kg)
4. Connector kit available, order part no. ‘CCH CONKIT’
0.20
(5.00)
0.27
(6.80)
8.23 (209.00)
Thermal Considerations
The baseplate must be maintained below 85 °C and therefore a suitable heatsink must be selected to remove the heat from the power supply.
Details of the heatsink calculations and other considerations can be found in the longform datasheet.
50
0
-40
Some specification
parameters may not be met
Output Load (%)
100
-20
0
+70
Ambient Temperature (ºC)
23-Jul-13